MLMichael L. Lieber

Michael L. Lieber

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael L. Lieber has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of protocol choice on phase contrast cardiac magnetic resonance flow measurement in the ascending aorta: breath-hold and non-breath-hold

    by Michael A. Bolen, Randolph M. Setser, Ruvin S. Gabriel, Rahul D. Renapurkar, Yasmeen Tandon, Michael L. Lieber, Milind Y. Desai, Scott D. Flamm

    Flow assessment with phase contrast magnetic resonance imaging (PC-MRI) protocols is an important component of a comprehensive cardiovascular MR (CMR) assessment. Breath-hold (BH) and non-breath-hold (NBH) PC-MRI protocols are widely available for this imaging modality. Because flow in the great vessels is known to vary with the respiratory cycle, we hypothesized that these 2 approaches might yield different results in the clinical assessment of forward and regurgitant flow in the ascending aorta. Further, given renewed awareness of the possible effect of velocity offsets in PC-MRI, we also sought to evaluate the impact of BH and NBH protocols on this potential source of error. A prospective observational study was performed in 55 consecutive patients referred for clinical CMR of the thoracic aorta. Both BH and NBH protocols were performed at the sinotubular junction and at the mid ascending aorta. Ten additional patients underwent repeated scanning at the mid ascending aorta with both BH and NBH protocols so that protocol variability could be assessed. Finally, ten patients were scanned with both BH and NBH protocols, and phantoms were then imaged with identical imaging parameters so that offset errors associated with each protocol could be evaluated. Forward flow was generally greater with the NBH protocol than with the BH protocol (mean values 102.1 mL vs. 97.9 mL; P = 0.0004). The Bland–Altman limits of agreement were quite wide for all indices (e.g, forward flow, −26.7 mL, +18.2 mL), which suggests that results from BH and NBH protocols cannot be interchanged with confidence. Estimated phase offset errors were similar for both protocols and were generally within acceptable ranges at the mid ascending level, with slightly higher values observed at the sinotubular junction for the BH technique. We observed differences in flow values with BH and NBH protocols for PC-MRI. This finding is relevant to patients imaged serially for the evaluation of cardiac output or valve (aortic or mitral) insufficiency, for whom adherence to one PC-MRI breathing protocol is likely most effective.


  • Cine Delayed-Enhancement MR Imaging of the Heart: Initial Experience

    by Randolph M. Setser, Jae K. Kim, Yiu Cho Chung, Kevin Chen, Arthur E. Stillman, Ralf Loeffler, Orlando P. Simonetti, Joan A. Weaver, Michael L. Lieber, Richard D. White

    This study was performed by using an institutional review board–approved protocol, with waived informed consent and HIPAA compliance. The purpose of this study was to preliminarily evaluate a cine delayed-enhancement (DE) pulse sequence for depiction of wall motion and myocardial scar extent during a single acquisition. The technique is based on inversion-recovery single-shot balanced steady-state free precession magnetic resonance imaging. Cine DE images were acquired in 26 patients (18 men, eight women; age range, 25–84 years; mean age, 61 years ± 13 [standard deviation]). Image contrast was consistent throughout each series. Overall (ie, with both readers' scores averaged), the cine DE imaging–depicted wall motion was scored correctly in 71% of myocardial segments. Scar extent was scored correctly in 76% of segments; in no patient was scarring missed. Cine DE imaging is a promising technique for simultaneous visualization of wall motion and myocardial scar extent. © RSNA, 2006