Ryan Fitzgerald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ryan Fitzgerald has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Denis E. Bergeron
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, 20899-8462, USA
6 shared publications - Jeffrey T. Cessna
National Institute of Standards and Technology, Gaithersburg, MD 20899
4 shared publications L. Pibida
NIST
4 shared publications- Brian E. Zimmerman
Natl Inst Stand & Technol NIST, Gaithersburg, MD USA
3 shared publications - Leticia Pibida
National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA
3 shared publications Ronald E. Tosh
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
3 shared publications
Latest Publications
- 3 January 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 205, 111171
Absolute emission intensities of the gamma rays from the decay of 224Ra and 212Pb progenies and the half-life of the 212 Pb decay
- 3 January 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 205, 111171
Absolute emission intensities of the gamma rays from the decay of 224Ra and 212Pb progenies and the half-life of the 212 Pb decay
- Open Access
- 1 January 2021
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 126
Toward a New Primary Standardization of Radionuclide Massic Activity Using Microcalorimetry and Quantitative Milligram-Scale Samples
We present a new paradigm for the primary standardization of radionuclide activity per mass of solution (Bq/g). Two key enabling capabilities are 4π decay-energy spectrometry using chip-scale sub-Kelvin microcalorimeters and direct realization of mass by gravimetric inkjet dispensing using an electrostatic force balance. In contrast to traditional traceability, which typically relies on chemical separation of single-radionuclide samples, 4π integral counting, and additional spectrometry methods to verify purity, the system described here has both 4π counting efficiency and spectroscopic resolution sufficient to identify multiple radionuclides in the same sample at once. This enables primary standardization of activity concentrations of mixed-radionuclide samples. A major benefit of this capability, beyond metrology, is in assay of environmental and forensics samples, for which the quantification of multiplenuclide samples can be achieved where presently inhibited by interferences. This can be achieved without the need for chemical separations or efficiency tracers, thereby vastly reducing time, radioactive waste, and resulting measurement uncertainty.
- 1 January 2021
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 126
Open AccessToward a New Primary Standardization of Radionuclide Massic Activity Using Microcalorimetry and Quantitative Milligram-Scale Samples
We present a new paradigm for the primary standardization of radionuclide activity per mass of solution (Bq/g). Two key enabling capabilities are 4π decay-energy spectrometry using chip-scale sub-Kelvin microcalorimeters and direct realization of mass by gravimetric inkjet dispensing using an electrostatic force balance. In contrast to traditional traceability, which typically relies on chemical separation of single-radionuclide samples, 4π integral counting, and additional spectrometry methods to verify purity, the system described here has both 4π counting efficiency and spectroscopic resolution sufficient to identify multiple radionuclides in the same sample at once. This enables primary standardization of activity concentrations of mixed-radionuclide samples. A major benefit of this capability, beyond metrology, is in assay of environmental and forensics samples, for which the quantification of multiplenuclide samples can be achieved where presently inhibited by interferences. This can be achieved without the need for chemical separations or efficiency tracers, thereby vastly reducing time, radioactive waste, and resulting measurement uncertainty.
- 1 September 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 163, 109216
The next generation of current measurement for ionization chambers
- 1 September 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 163, 109216
The next generation of current measurement for ionization chambers
- 1 May 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 159, 109101
Accurate integral counting using multi-channel analyzers
- 1 May 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 159, 109101
Accurate integral counting using multi-channel analyzers
- Open Access
- 6 April 2020
- Published by American Chemical Society (ACS)
228Th breakthrough in 224Ra samples: what can we know and when can we know it?
- 6 April 2020
- Published by American Chemical Society (ACS)
Open Access228Th breakthrough in 224Ra samples: what can we know and when can we know it?
- 15 March 2019
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 320 (3) , 889
Correction to: Primary standardization of the massic activity of a 233Pa solution
- 15 March 2019
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 320 (3) , 889
Correction to: Primary standardization of the massic activity of a 233Pa solution
- Open Access
- 29 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 13007
Assessing Radiation Hardness of Silicon Photonic Sensors
In recent years, silicon photonic platforms have undergone rapid maturation enabling not only optical communication but complex scientific experiments ranging from sensors applications to fundamental physics investigations. There is considerable interest in deploying photonics-based communication and science instruments in harsh environments such as outer space, where radiation damage is a significant concern. In this study, we have examined the impact of cobalt-60 γ-ray radiation up to 1 megagray (MGy) absorbed dose on silicon photonic devices. We do not find any systematic impact of radiation on passivated devices, indicating the durability of passivated silicon devices under harsh conditions.
- 29 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 13007
Open AccessAssessing Radiation Hardness of Silicon Photonic Sensors
In recent years, silicon photonic platforms have undergone rapid maturation enabling not only optical communication but complex scientific experiments ranging from sensors applications to fundamental physics investigations. There is considerable interest in deploying photonics-based communication and science instruments in harsh environments such as outer space, where radiation damage is a significant concern. In this study, we have examined the impact of cobalt-60 γ-ray radiation up to 1 megagray (MGy) absorbed dose on silicon photonic devices. We do not find any systematic impact of radiation on passivated devices, indicating the durability of passivated silicon devices under harsh conditions.
- 23 August 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 318 (1) , 149-155
Primary standardization of the massic activity of a 233Pa solution
Protactinium-233 (233Pa) is used as a tracer for radiochemical analysis and is of particular interest as an isotope dilution mass spectrometry (IDMS) spike for 231Pa/235U radio-chronometry. To this end, we present massic activity determinations by two methods for a 233Pa solution, which was prepared at Lawrence Livermore National Laboratory (LLNL) and is being characterized at multiple labs as part of a 231Pa reference material production project. One activity determination method was 4πβ-γ anti-coincidence counting in a multi-dimensional extrapolation model, with Monte Carlo corrections. An independent massic activity determination was completed by \(\gamma\)-ray spectrometry using 5 high purity germanium (HPGe) detectors using 5 \(\gamma\)-ray lines. The anti-coincidence and \(\gamma\)-ray spectrometry results agree and have combined standard uncertainties of about 0.33% and 1.0% respectively. In addition, the two methods were combined to derive \(\gamma\)-ray emission probabilities from 233Pa decay.- 23 August 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 318 (1) , 149-155
Primary standardization of the massic activity of a 233Pa solution
Protactinium-233 (233Pa) is used as a tracer for radiochemical analysis and is of particular interest as an isotope dilution mass spectrometry (IDMS) spike for 231Pa/235U radio-chronometry. To this end, we present massic activity determinations by two methods for a 233Pa solution, which was prepared at Lawrence Livermore National Laboratory (LLNL) and is being characterized at multiple labs as part of a 231Pa reference material production project. One activity determination method was 4πβ-γ anti-coincidence counting in a multi-dimensional extrapolation model, with Monte Carlo corrections. An independent massic activity determination was completed by \(\gamma\)-ray spectrometry using 5 high purity germanium (HPGe) detectors using 5 \(\gamma\)-ray lines. The anti-coincidence and \(\gamma\)-ray spectrometry results agree and have combined standard uncertainties of about 0.33% and 1.0% respectively. In addition, the two methods were combined to derive \(\gamma\)-ray emission probabilities from 233Pa decay.- Open Access
Radiation Hardness of Fiber Bragg Grating Thermometers
Photonics sensing has long been valued for its tolerance to harsh environments where traditional sensing technologies fail. As photonic components continue to evolve and find new applications, their tolerance to radiation is emerging as an important line of inquiry. Here we report on our investigation of the impact of gamma-ray exposure on the temperature response of fiber Bragg gratings. At 25 degrees C, exposures leading to an accumulated dose of up to 600 kGy result in complex dose-dependent drift in Bragg wavelength, significantly increasing the uncertainty in temperature measurements obtained if appreciable dose is delivered over the measurement interval. We note that temperature sensitivity is not severely impacted by the integrated dose, suggesting such devices could be used to measure relative changes in temperature.
Open AccessRadiation Hardness of Fiber Bragg Grating Thermometers
Photonics sensing has long been valued for its tolerance to harsh environments where traditional sensing technologies fail. As photonic components continue to evolve and find new applications, their tolerance to radiation is emerging as an important line of inquiry. Here we report on our investigation of the impact of gamma-ray exposure on the temperature response of fiber Bragg gratings. At 25 degrees C, exposures leading to an accumulated dose of up to 600 kGy result in complex dose-dependent drift in Bragg wavelength, significantly increasing the uncertainty in temperature measurements obtained if appreciable dose is delivered over the measurement interval. We note that temperature sensitivity is not severely impacted by the integrated dose, suggesting such devices could be used to measure relative changes in temperature.