Jeffrey T. Cessna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeffrey T. Cessna has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Brian E. Zimmerman
Natl Inst Stand & Technol NIST, Gaithersburg, MD USA
4 shared publications - Denis E. Bergeron
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, 20899-8462, USA
4 shared publications - Ryan Fitzgerald
National Institute of Standards and Technology, Gaithersburg, MD 20899
4 shared publications - Leticia Pibida
National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA
3 shared publications - B E Zimmerman
Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8462, USA
2 shared publications B.E. Zimmerman
Physical Measurements Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
2 shared publications
Latest Publications
- 3 January 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 205, 111171
Absolute emission intensities of the gamma rays from the decay of 224Ra and 212Pb progenies and the half-life of the 212 Pb decay
- 3 January 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 205, 111171
Absolute emission intensities of the gamma rays from the decay of 224Ra and 212Pb progenies and the half-life of the 212 Pb decay
- 1 April 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 134, 385-390
Results of an international comparison of activity measurements of 68Ge
- 1 April 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 134, 385-390
Results of an international comparison of activity measurements of 68Ge
- 1 March 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 109, 402-404
Source self-attenuation in ionization chamber measurements of 57Co solutions
- 1 March 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 109, 402-404
Source self-attenuation in ionization chamber measurements of 57Co solutions
- 1 March 2015
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 120, 37-57
Revision of the NIST Standard for 223 Ra: New Measurements and Review of 2008 Data
After discovering a discrepancy in the transfer standard currently being disseminated by the National Institute of Standards and Technology (NIST), we have performed a new primary standardization of the alpha-emitter (223)Ra using Live-timed Anticoincidence Counting (LTAC) and the Triple-to-Double Coincidence Ratio Method (TDCR). Additional confirmatory measurements were made with the CIEMAT-NIST efficiency tracing method (CNET) of liquid scintillation counting, integral γ-ray counting using a NaI(Tl) well counter, and several High Purity Germanium (HPGe) detectors in an attempt to understand the origin of the discrepancy and to provide a correction. The results indicate that a -9.5 % difference exists between activity values obtained using the former transfer standard relative to the new primary standardization. During one of the experiments, a 2 % difference in activity was observed between dilutions of the (223)Ra master solution prepared using the composition used in the original standardization and those prepared using 1 mol·L(-1) HCl. This effect appeared to be dependent on the number of dilutions or the total dilution factor to the master solution, but the magnitude was not reproducible. A new calibration factor ("K-value") has been determined for the NIST Secondary Standard Ionization Chamber (IC "A"), thereby correcting the discrepancy between the primary and secondary standards.
- 1 March 2015
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 120, 37-57
Revision of the NIST Standard for 223 Ra: New Measurements and Review of 2008 Data
After discovering a discrepancy in the transfer standard currently being disseminated by the National Institute of Standards and Technology (NIST), we have performed a new primary standardization of the alpha-emitter (223)Ra using Live-timed Anticoincidence Counting (LTAC) and the Triple-to-Double Coincidence Ratio Method (TDCR). Additional confirmatory measurements were made with the CIEMAT-NIST efficiency tracing method (CNET) of liquid scintillation counting, integral γ-ray counting using a NaI(Tl) well counter, and several High Purity Germanium (HPGe) detectors in an attempt to understand the origin of the discrepancy and to provide a correction. The results indicate that a -9.5 % difference exists between activity values obtained using the former transfer standard relative to the new primary standardization. During one of the experiments, a 2 % difference in activity was observed between dilutions of the (223)Ra master solution prepared using the composition used in the original standardization and those prepared using 1 mol·L(-1) HCl. This effect appeared to be dependent on the number of dilutions or the total dilution factor to the master solution, but the magnitude was not reproducible. A new calibration factor ("K-value") has been determined for the NIST Secondary Standard Ionization Chamber (IC "A"), thereby correcting the discrepancy between the primary and secondary standards.
- 1 August 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 371-96
A Review of NIST Primary Activity Standards for 18F: 1982 to 2013
The new NIST activity standardization for (18)F, described in 2014 in Applied Radiation and Isotopes (v. 85, p. 77), differs from results obtained between 1998 and 2008 by 4 %. The new results are considered to be very reliable; they are based on a battery of robust primary measurement techniques and bring the NIST standard into accord with other national metrology institutes. This paper reviews all ten (18)F activity standardizations performed at NIST from 1982 to 2013, with a focus on experimental variables that might account for discrepancies. We have identified many possible sources of measurement bias and eliminated most of them, but we have not adequately accounted for the 1998-2008 results.
- 1 August 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 371-96
A Review of NIST Primary Activity Standards for 18F: 1982 to 2013
The new NIST activity standardization for (18)F, described in 2014 in Applied Radiation and Isotopes (v. 85, p. 77), differs from results obtained between 1998 and 2008 by 4 %. The new results are considered to be very reliable; they are based on a battery of robust primary measurement techniques and bring the NIST standard into accord with other national metrology institutes. This paper reviews all ten (18)F activity standardizations performed at NIST from 1982 to 2013, with a focus on experimental variables that might account for discrepancies. We have identified many possible sources of measurement bias and eliminated most of them, but we have not adequately accounted for the 1998-2008 results.
- 1 August 2013
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 118, 359-74
Calibration of Traceable Solid Mock 131I Phantoms Used in an International SPECT Image Quantification Comparison
The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid (133)Ba sources were used as a long-lived surrogate for (131)I. For this study, we designed a set of solid cylindrical sources so that each site could have a set of phantoms (having nominal volumes of 2 mL, 4 mL, 6 mL, and 23 mL) with traceable activity calibrations so that the results could be properly compared. We also developed a technique using two different detection methods for individually calibrating the sources for (133)Ba activity based on a National standard. This methodology allows for the activity calibration of each (133)Ba source with a standard uncertainty on the activity of 1.4 % for the high-level 2-, 4-, and 6-mL sources and 1.7 % for the lower-level 23 mL cylinders. This level of uncertainty allows for these sources to be used for the intended comparison exercise, as well as in other SPECT image quantification studies.
- 1 August 2013
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 118, 359-74
Calibration of Traceable Solid Mock 131I Phantoms Used in an International SPECT Image Quantification Comparison
The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid (133)Ba sources were used as a long-lived surrogate for (131)I. For this study, we designed a set of solid cylindrical sources so that each site could have a set of phantoms (having nominal volumes of 2 mL, 4 mL, 6 mL, and 23 mL) with traceable activity calibrations so that the results could be properly compared. We also developed a technique using two different detection methods for individually calibrating the sources for (133)Ba activity based on a National standard. This methodology allows for the activity calibration of each (133)Ba source with a standard uncertainty on the activity of 1.4 % for the high-level 2-, 4-, and 6-mL sources and 1.7 % for the lower-level 23 mL cylinders. This level of uncertainty allows for these sources to be used for the intended comparison exercise, as well as in other SPECT image quantification studies.
- 1 September 2012
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 70 (9) , 2227-2231
The NIST radioactivity measurement assurance program for the radiopharmaceutical industry
- 1 September 2012
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 70 (9) , 2227-2231
The NIST radioactivity measurement assurance program for the radiopharmaceutical industry
- 1 July 2010
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 68 (7-8) , 1523-1528
Standardization of radium-223 by liquid scintillation counting
- 1 July 2010
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 68 (7-8) , 1523-1528
Standardization of radium-223 by liquid scintillation counting
- 1 September 2008
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 113 (5) , 265-80
Standardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods
A solution containing (68)Ge in equilibrium with its daughter, (68)Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and (3)H-standard efficiency tracing with the CIEMAT(1)/NIST (CNET) method. The LTAC technique is much less dependent on level scheme data and model-dependent parameters and was thus able to provide a reference activity concentration value for the master solution with a combined standard uncertainty of about 0.3 %. The other two methods gave activity concentration values with respective differences from the reference value of +1.2 % and -1.5 %, which were still within the experimental uncertainties. Measurements made on the NIST "4π"γ secondary standard ionization chamber allowed for the determination of calibration factors for that instrument, allowing future calibrations to be made for (68)Ge/(68)Ga without the need for a primary measurement. The ability to produce standardized solutions of (68)Ge presents opportunities for the development of a number of NIST-traceable calibration sources with very low (<1 %) relative standard uncertainties that can be used in diagnostic medical imaging.
- 1 September 2008
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 113 (5) , 265-80
Standardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods
A solution containing (68)Ge in equilibrium with its daughter, (68)Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and (3)H-standard efficiency tracing with the CIEMAT(1)/NIST (CNET) method. The LTAC technique is much less dependent on level scheme data and model-dependent parameters and was thus able to provide a reference activity concentration value for the master solution with a combined standard uncertainty of about 0.3 %. The other two methods gave activity concentration values with respective differences from the reference value of +1.2 % and -1.5 %, which were still within the experimental uncertainties. Measurements made on the NIST "4π"γ secondary standard ionization chamber allowed for the determination of calibration factors for that instrument, allowing future calibrations to be made for (68)Ge/(68)Ga without the need for a primary measurement. The ability to produce standardized solutions of (68)Ge presents opportunities for the development of a number of NIST-traceable calibration sources with very low (<1 %) relative standard uncertainties that can be used in diagnostic medical imaging.
- 1 June 2008
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 66 (6-7) , 988-993
Radionuclide calibrator measurements of 18F in a 3ml plastic syringe
- 1 June 2008
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 66 (6-7) , 988-993
Radionuclide calibrator measurements of 18F in a 3ml plastic syringe