MHM. Hanada

M. Hanada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


M. Hanada has a total of 83 co-authors. Here are the top co-authors by number of shared publications:

  • T. Inoue

    Japan Atomic Energy Research Institute, 801‐1 Mukoyama, Naka‐machi, Naka‐gun, Ibaraki‐ken, 311‐0193 Japan

    7 shared publications
  • K. Miyamoto

    Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502, Japan

    5 shared publications
  • K. Watanabe

    Japan Atomic Energy Research Institute, 801‐1 Mukoyama, Naka‐machi, Naka‐gun, Ibaraki‐ken, 311‐0193 Japan

    5 shared publications
  • M. Kashiwagi

    National Institute for Quantum and Radiological Science and Technology, Japan

    4 shared publications
  • Y. Ohara

    Japan Atomic Energy Research Institute 801-1, Mukoyama, Naka-machi, Naka-gun, Ibaraki-ken, 311-01, Japan

    3 shared publications
  • Y. Okumura

    Japan Atomic Energy Research Institute, 801-1 Mukoyama, Naka-machi, Naka-gun, Ibaraki-ken 311-0193, Japan

    3 shared publications

Latest Publications

  • Study of negative hydrogen ion beam optics using the 2D PIC method

    by K. Miyamoto, S. Okuda, A. Hatayama, M. Hanada, A. Kojima

    We have developed the integrated 2D PIC code for the analysis of the negative ion beam optics, in which an overall region from the source plasma to the accelerator is modeled. Thus, the negative ion trajectory can be solved self-consistently without any assumption of the plasma meniscus form initially. This code can reproduce the negative ion beam halo observed in an actual negative ion beam. It is confirmed that the surface produced negative ions which are extracted near the edge of the meniscus can be one of the reasons for the beam halo: these negative ions are over-focused due to the curvature of the meniscus. The negative ions are not focused by the electrostatic lens, and consequently become the beam halo.


  • Study of plasma meniscus formation and beam halo in negative hydrogen ion sources

    by S. Okuda, K. Miyamoto, T. Fukuyama, S. Nishioka, A. Hatayama, A. Fukano, M. Hanada, A. Kojima

    A meniscus of plasma-beam boundary in H− ion sources largely affects the extracted H− ion beam optics. Recently it is shown that the beam halo is mainly caused by the meniscus, i.e. ion emissive surface, close to the plasma grid (PG) where its curvature is large. The purpose of this study is to clarify the effect of H− surface production rate on plasma meniscus and beam halo formation with PIC (particle-in-cell) modeling. It is shown that the plasma meniscus and beam halo formation is strongly dependent on the amount of surface produced H− ions.


  • Compensation of beamlet repulsion in a large negative ion source with a multi aperture accelerator

    by M. Kashiwagi, T. Inoue, L. R. Grisham, M. Hanada, M. Kamada, M. Taniguchi, N. Umeda, K. Watanabe, Elizabeth Surrey, Alain Simonin

    Excess heat loads to accelerator grids limit extension of pulse length in operation of the large negative ion sources with multi aperture accelerator. Part of the heat loads is caused by interception of deflected beamlets due to their space charge repulsion. In this paper, a beamlet steering technique using aperture offset was examined for compensation of the beamlet deflections utilizing a three dimensional beam analysis simulating the D− negative ion source of JT‐60 U. The beamlet deflection was analyzed in detail using fifty beamlets, which were extracted from apertures arranged in a lattice pattern of 10×5. The simulation showed successful compensation of the beamlet deflection by aperture offsets defined according to the thin lens theory. Even if the beam energy was changed, the necessary aperture offset would not be changed maintaining the perveance and a ratio of extraction and acceleration voltage. In JT‐60 U, it was shown that the aperture offset of less than 1.0 mm would be enough to compensate the repulsion of all beamlets. When the magnetic field was applied for suppression of co‐extracted electrons, necessary aperture offset was estimated to be ±0.5 mm for 500 keV D− ion beam in JT‐60 U, in addition to the offset for the space charge repulsion. This result showed good agreements with the previous experimental results and design study of the JT‐60 U N‐NBI.


  • Acceleration of 100A/m2 Negative Hydrogen Ion Beams in a 1 MeV Vacuum Insulated Beam Source

    by M. Taniguchi, T. Inoue, M. Kashiwagi, M. Hanada, K. Watanabe, K. Seki, K. Sakamoto

    In the ITER NB, conventional gas insulated beam source (GIBS) cannot be utilized because of the radiation‐induced conductivity of the insulation gas. Thus a vacuum insulated beam source (VIBS), where the whole beam source is immersed in vacuum, has been developed at JAERI. Recently, voltage holding capability of the VIBS was drastically improved by the large stress ring, which reduces the electric field concentration at the triple junction. Up to now, a high current density H− beam of 102 A/m2 (140 mA) at 800 keV has been accelerated. The beam acceleration was quite stable and accomplished for several hundreds shots. The degradation of the voltage holding due to the beam acceleration and/or Cs seeding was not observed. Thus the development of vacuum insulated beam source has solved technical issues of high voltage insulation of 1 MV level under the presence of the H− ion beams.

  • Acceleration of 1 MeV, 100 mA Class H− ion beams in a proof-of-principle accelerator for ITER

    by T. Inoue, M. Taniguchi, M. Dairaku, M. Hanada, M. Kashiwagi, T. Morishita, K. Watanabe, T. Imai

    Development of an electrostatic accelerator for 1 MeV, 1 ampere class H− ion beams has been carried out as a Proof-of-Principle (PoP) of high current accelerators required in neutral beam system of fusion reactors such as ITER. A unique feature of such fusion oriented accelerators is to utilize vacuum insulation not only inside but also outside of the accelerator for high voltage insulation, since conventional gas insulation is not applicable due to excess radiation induced conductivity in the gas. The PoP accelerator is surrounded by an insulator stack as a vacuum boundary with a vacuum gap of 50 mm all around the accelerator. One of the key technologies to achieve insulation of MV voltage was reduction of electric field strength at triple junction of the insulator (made of FRP, fiber reinforced plastic) stack. By lowering the stress to 1.7 kV/mm, the accelerator sustained 1 MV stably for more than 2 hours. By tuning the ion source with/without cesium under stable accelerator operation, the PoP accelerator generated H− ion beams of 70 mA at 1 MeV, and 110 mA (80 A/m2) at 900 keV stably for several hundreds shots (pulse length, 0.5–1 s limited by the target). The dark current flowed inside/on the surface of the FRP insulator due to photoelectron effect was estimated to be less than μA in case of 0.1 A electron beam acceleration (maximum current observed in the experiment). This is in the same order to that due to conductivity of the insulator material. So far, high voltage breakdown due to photoelectron has never been observed.


  • Development of a large volume negative-ion source for ITER neutral beam injector

    by K. Watanabe, T. Amemiya, M. Hanada, T. Iga, T. Imai, T. Inoue, M. Kashiwagi, M. Kuriyama, T. Morishita, Y. Okumura, et al.

    Development of the negative-ion sources has been conducted to realize a high power neutral beam injector for International Thermonuclear Experimental Reactor (ITER). A high negative-ion current density of 31 mA/cm2 (H−) at a very low pressure of 0.1 Pa has been produced in a cesium seeded multicusp plasma generator which has the same concept of the ITER source. For a vacuum insulated accelerator, a voltage holding experiment of long distance vacuum gaps up to ∼1.8 m has been performed. It was clarified that the transition region of product pressure distance (pd) from the vacuum breakdown to the gas discharge is about 0.2 Pa m which is high enough from the operating region of the ITER source. A prototype vacuum insulated accelerator was fabricated based on the experiment and tested. A high-energy H− beam acceleration up to 970 keV, 37 mA, and 1 s has been successfully demonstrated.


  • Beam transmission in the ITER neutral beam injectors

    by A. Krylov, E. Di Pietro, E. Dlugach, T. Inoue, M. Hanada, R. Hemsworth, K. Miyamoto, A. Panasenkov

  • Radiation induced conductivity and voltage holding characteristics of insulation gas for the ITER NBI

    by Y. Fujiwara, M. Hanada, T. Inoue, K. Miyamoto, N. Miyamoto, Y. Ohara, Y. Okumura, K. Watanabe

    An irradiation experiment on insulation gas was carried out to evaluate ionization current and voltage holding characteristics with the gamma-rays from Co-60. The gases of air, SF6, C2F6, CO2, and mixture of air and SF6 were investigated using parallel-disk electrodes all the absorbed dose rate of up to 0.45 Gy/s. Ionization current increased linearly with gap length between electrodes, gas pressure, absorbed dose rate, and molecular weight. An experimental formula to estimate ionization current was obtained on the basis of experimental results. Degradation of breakdown voltage with gamma-rays was at most about 10%; however, the degree of the degradation did not depend strongly on absorbed dose rate.


    • 1 November 1997
      • Vol. 24  (14) , 2111-6

    [Preoperative chemoradiation therapy for advanced rectal cancer].

    by T Tsujinaka, M Murotani, K Iihara, M Takami, T Takada, M Kitada, Y Tsukahara, T Shibata, T Niinobu, M Ogawa, et al.

    Preoperative concurrent chemoradiation therapy with 5-fluorouracil and cisplatin was applied for advanced rectal cancer. Eligible criteria were as follows: no previous treatment, 4 more than hemicircular occupation, T3 or more invasion to adjacent organs or lymph node metastasis on CT scan, tumor fixation by digital examination. Eleven patients were enrolled with this regimen consisting of 5-FU; 500mg/day x5/w x4, CDDP; 10mg/day X 5/w x4 and radiation; 2Gy x 5/w x 4. As a toxicity, grade 2 leukopenia in 2 cases, grade 2 GI symptoms in one case and radiation dermatitis was observed in 8 cases. As a local response, there were PR in 10 cases and NC in 1 case. Surgical resection was performed on 8 patients. Histological responses in the resected specimens were grade 2, 5 cases; grade 1b, 1 case; and grade la, 2 cases. Operative radicalities were grade A, 3 cases; grade B, 3 cases; and grade C, 2 cases. Preoperative chemoradiation is one of the effective options in multimodal treatment for advanced rectal cancer.

  • Beam acceleration test in negative-ion based NBI system for JT-60U

    by K. Watanabe, N. Akino, M. Araki, N. Ebisawa, Y. Fujiwara, M. Hanada, A. Honda, T. Inoue, T. Itoh, M. Kawai, et al.

    Beam extraction and acceleration test in the Negative Ion Based Neutral Beam Injector for JT‐60U has been started using one ion source that is designed to produce a 500 keV, 22 A D− ion beam. Deuterium negative ions are produced in a cesium‐seeded semi‐cylindrical plasma generator and accelerated by a multi‐aperture three‐stage electrostatic accelerator. In the preliminary experiment of beam acceleration, the D− ion beam of 13.5 A was successfully accelerated to 400 keV for a pulse duration of 0.12 s. The negative ion beam power was 5.4 MW. The operating gas pressure in the plasma generator was as low as 0.22 Pa. The highest energy beam of 460 keV, 2.4 A, 0.44 s was also obtained. The ratio of extracted electron current to extracted negative ion current is estimated Ie/ID−<1. It was confirmed that the electron leak from the extractor to the accelerator is suppressed efficiently by the effects of biassing, electron trapping gap and magnetic field.