Dawn E. Lehman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dawn E. Lehman has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Charles W. Roeder
Department of Civil and Environmental Engineering University of Washington Seattle Washington USA
9 shared publications - Laura N. Lowes
Research Assistant, Dept. of Civil and Environmental Engineering, University of Washington, Seattle, WA 98195
3 shared publications Aaron W. Olson
Assistant Professor, Dept. of Civil and Environmental Engineering, Univ. of Washington, 214C More Hall, Box 352700, Seattle, WA 98195
1 shared publicationAmanda Jellin
Department of Civil and Environmental Engineering, University of Washington, Seattle, WA 98195-2700
1 shared publication- Anna C. Birely
Assistant Professor, Zachry Dept. of Civil Engineering, Texas A&M Univ., 3136 TAMU, College Station, TX 77843. ORCID:
1 shared publication Bo-Shiuan Wang
Assistant Professor, Dept. of Civil and Environmental Engineering, Univ. of Washington, 214C More Hall, Box 352700, Seattle, WA 98195
1 shared publication
Latest Publications
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 139 (12)
Strength of Circular Concrete-Filled Tubes with and without Internal Reinforcement under Combined Loading
Concrete-filled tubes (CFTs) have been used in civil engineering practice as piles, caissons, columns, and bridge piers. Relative to conventional structural steel and reinforced concrete components, CFTs have several advantages. The steel tube serves as both reinforcement and formwork, eliminating the need for both, and provides large tensile and compressive capacities; the concrete fill restrains buckling of the steel tube, which increases the strength, stiffness, and deformability of the section. In some cases, internal reinforcement is used to enhance the strength and facilitate connection to adjacent members. Although these properties are well accepted, the use of CFTs in practice is awkward because design provisions among codes vary significantly and previous research has not considered internal reinforcement. An analytical research study was undertaken to evaluate and improve design provisions for CFTs with and without internal reinforcement under combined axial load and bending. A continuum...
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 139 (12)
Strength of Circular Concrete-Filled Tubes with and without Internal Reinforcement under Combined Loading
Concrete-filled tubes (CFTs) have been used in civil engineering practice as piles, caissons, columns, and bridge piers. Relative to conventional structural steel and reinforced concrete components, CFTs have several advantages. The steel tube serves as both reinforcement and formwork, eliminating the need for both, and provides large tensile and compressive capacities; the concrete fill restrains buckling of the steel tube, which increases the strength, stiffness, and deformability of the section. In some cases, internal reinforcement is used to enhance the strength and facilitate connection to adjacent members. Although these properties are well accepted, the use of CFTs in practice is awkward because design provisions among codes vary significantly and previous research has not considered internal reinforcement. An analytical research study was undertaken to evaluate and improve design provisions for CFTs with and without internal reinforcement under combined axial load and bending. A continuum...
- 1 March 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 17 (2) , 221-231
Rapid Assessment of Gusset Plate Safety in Steel Truss Bridges
Research into the cause of the failure of the I-35W Bridge in Minneapolis, Minnesota, has indicated that some of the gusset plates were significantly overstressed. The Federal Highway Administration has recommended load rating all gusset plate connections in bridges around the country using their recommended load rating procedures, which are complex and require a large commitment of resources. Further, the procedures use approximate ultimate capacity and therefore do not address serviceability or bridge longevity, which require prediction of gusset plate yielding, not collapse. A triage evaluation procedure is proposed to enable rapid, yet conservative, identification of gusset plates that may be yielding under service loads and to eliminate gusset plates with adequate capacity from needing further or more sophisticated analysis. High-resolution finite element models of gusset plate connections from Washington State bridges and the connection identified as critical from the I-35W Bridge are used to develop the proposed procedure and evaluate the current recommendations. A complex interaction of stresses is generated in gusset plates by connecting members, and this interaction can initiate gusset plate yielding when the uniaxial stresses on Whitmore sections associated with those connecting members are well below yield. It is demonstrated that the onset of gusset plate yielding may be conservatively predicted by comparing the uniaxial stresses at Whitmore sections with . Additionally, a modification to the simple column analogy method recommended by FHWA for calculating the buckling capacity of gusset plates is proposed, and it is shown that gusset plate yielding occurs prior to buckling in all cases considered. The triage evaluation procedure is grounded in mechanics and conservative assumptions, enabling more rapid identification of problem gusset plates while also being reasonably conservative. The method is then applied to three bridges, from which 3 gusset plates out of 35 are identified as requiring additional investigation.- 1 March 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 17 (2) , 221-231
Rapid Assessment of Gusset Plate Safety in Steel Truss Bridges
Research into the cause of the failure of the I-35W Bridge in Minneapolis, Minnesota, has indicated that some of the gusset plates were significantly overstressed. The Federal Highway Administration has recommended load rating all gusset plate connections in bridges around the country using their recommended load rating procedures, which are complex and require a large commitment of resources. Further, the procedures use approximate ultimate capacity and therefore do not address serviceability or bridge longevity, which require prediction of gusset plate yielding, not collapse. A triage evaluation procedure is proposed to enable rapid, yet conservative, identification of gusset plates that may be yielding under service loads and to eliminate gusset plates with adequate capacity from needing further or more sophisticated analysis. High-resolution finite element models of gusset plate connections from Washington State bridges and the connection identified as critical from the I-35W Bridge are used to develop the proposed procedure and evaluate the current recommendations. A complex interaction of stresses is generated in gusset plates by connecting members, and this interaction can initiate gusset plate yielding when the uniaxial stresses on Whitmore sections associated with those connecting members are well below yield. It is demonstrated that the onset of gusset plate yielding may be conservatively predicted by comparing the uniaxial stresses at Whitmore sections with . Additionally, a modification to the simple column analogy method recommended by FHWA for calculating the buckling capacity of gusset plates is proposed, and it is shown that gusset plate yielding occurs prior to buckling in all cases considered. The triage evaluation procedure is grounded in mechanics and conservative assumptions, enabling more rapid identification of problem gusset plates while also being reasonably conservative. The method is then applied to three bridges, from which 3 gusset plates out of 35 are identified as requiring additional investigation.- 25 February 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 351-363
An Economical and Efficient Foundation Connection for Concrete Filled Steel Tube Piers and Columns
Concrete filled steel tubes (CFT) are economical and result in rapid construction. The steel tube serves as formwork and reinforcement to the concrete fill, and the fill increases the compressive strength and stiffness of the tube. The fill delays and restrains local buckling, and enhances ductility and resistance if composite action is achieved. Circular CFT provides better performance because the circular tube provides greater confinement of the concrete and composite interaction between the two materials. However, circular CFT is more difficult to connect to other structural elements, and recent research has provided a simple and economical connection to connect circular CFT piers or columns to reinforced concrete foundations, beams and pier caps. The connection does not require any reinforcement or dowels connecting the tube to the footing. A second variation of this connection permits sequencing of steel and concrete construction trades and connecting to precast concrete elements. A series of experiments have been completed to evaluate the inelastic seismic performance and establish design criteria for the connection. This work shows that the connection can develop the full capacity of the composite column, and provide great ductility and inelastic deformation capacity under seismic loading.
- 25 February 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 351-363
An Economical and Efficient Foundation Connection for Concrete Filled Steel Tube Piers and Columns
Concrete filled steel tubes (CFT) are economical and result in rapid construction. The steel tube serves as formwork and reinforcement to the concrete fill, and the fill increases the compressive strength and stiffness of the tube. The fill delays and restrains local buckling, and enhances ductility and resistance if composite action is achieved. Circular CFT provides better performance because the circular tube provides greater confinement of the concrete and composite interaction between the two materials. However, circular CFT is more difficult to connect to other structural elements, and recent research has provided a simple and economical connection to connect circular CFT piers or columns to reinforced concrete foundations, beams and pier caps. The connection does not require any reinforcement or dowels connecting the tube to the footing. A second variation of this connection permits sequencing of steel and concrete construction trades and connecting to precast concrete elements. A series of experiments have been completed to evaluate the inelastic seismic performance and establish design criteria for the connection. This work shows that the connection can develop the full capacity of the composite column, and provide great ductility and inelastic deformation capacity under seismic loading.
- 1 December 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 136 (12) , 1545-1553
Strength and Stiffness of Circular Concrete-Filled Tubes
Concrete-filled tubes (CFTs) are composite structural members that consist of a steel tube and concrete infill. CFTs optimize the contributions of both components by improving their geometric efficiency and fully using their inherent strengths. The concrete infill is confined by the steel tube, resulting in a triaxial state of compression that increases the strength and strain capacity of the concrete. The perimeter steel is at its optimal location, and the concrete infill delays local and global buckling of the tube. CFTs are easily and rapidly constructed and provide significant compression, bending, and shear resistance. They may be used for bridge piers and building columns. However, current design specifications for CFTs vary significantly, thereby limiting the current understanding and use of these components. This study addresses combined axial and flexural loading and determines the best models for predicting the stiffness and resistance of circular CFT. A database of 122 test specimens was compil...
- 1 December 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 136 (12) , 1545-1553
Strength and Stiffness of Circular Concrete-Filled Tubes
Concrete-filled tubes (CFTs) are composite structural members that consist of a steel tube and concrete infill. CFTs optimize the contributions of both components by improving their geometric efficiency and fully using their inherent strengths. The concrete infill is confined by the steel tube, resulting in a triaxial state of compression that increases the strength and strain capacity of the concrete. The perimeter steel is at its optimal location, and the concrete infill delays local and global buckling of the tube. CFTs are easily and rapidly constructed and provide significant compression, bending, and shear resistance. They may be used for bridge piers and building columns. However, current design specifications for CFTs vary significantly, thereby limiting the current understanding and use of these components. This study addresses combined axial and flexural loading and determines the best models for predicting the stiffness and resistance of circular CFT. A database of 122 test specimens was compil...
- Open Access
- 31 December 2009
- Published by American Institute of Steel Construction in Engineering Journal
- Vol. 46 (4) , 229-242
Composite Action in CFT Components and Connections
Concrete-filled steel tube (CFT) components provide an attractive alternative to conventional methods of construction. The steel tube serves as formwork and reinforcement to the concrete fill. The fill delays local buckling of the tube and increases the compressive strength, stiffness and ductility of the CFT member if composite action is achieved. As such, the benefits of using CFT components include their efficiency, economy and ability to provide rapid construction. The primary obstacles to using CFT components relate to achieving adequate shear-stress transfer between the two materials needed for composite behavior and to developing robust, constructible connections. There is considerable interaction between this stress transfer and the connections joining CFT members to other structural elements. In many cases, natural bond stress, primarily friction, is adequate to assure good structural performance of the CFT member, but in other cases mechanical interlock or bearing between the steel and concrete is required. While some mechanical transfer elements may supplement the natural bond transfer, others may destroy this beneficial effect. Additionally, natural bond may be dramatically enhanced by bending of the CFT member and by using appropriate connections to join other members to the CFT element. Therefore, proper quantification and understanding of natural, enhanced and mechanical sources of bond stress are needed to develop robust CFT structural components and their connections.
- 31 December 2009
- Published by American Institute of Steel Construction in Engineering Journal
- Vol. 46 (4) , 229-242
Open AccessComposite Action in CFT Components and Connections
Concrete-filled steel tube (CFT) components provide an attractive alternative to conventional methods of construction. The steel tube serves as formwork and reinforcement to the concrete fill. The fill delays local buckling of the tube and increases the compressive strength, stiffness and ductility of the CFT member if composite action is achieved. As such, the benefits of using CFT components include their efficiency, economy and ability to provide rapid construction. The primary obstacles to using CFT components relate to achieving adequate shear-stress transfer between the two materials needed for composite behavior and to developing robust, constructible connections. There is considerable interaction between this stress transfer and the connections joining CFT members to other structural elements. In many cases, natural bond stress, primarily friction, is adequate to assure good structural performance of the CFT member, but in other cases mechanical interlock or bearing between the steel and concrete is required. While some mechanical transfer elements may supplement the natural bond transfer, others may destroy this beneficial effect. Additionally, natural bond may be dramatically enhanced by bending of the CFT member and by using appropriate connections to join other members to the CFT element. Therefore, proper quantification and understanding of natural, enhanced and mechanical sources of bond stress are needed to develop robust CFT structural components and their connections.
- 24 June 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-13
Seismic Performance of Pile-Wharf Connections
Pile-supported marginal wharves are a critical infrastructure component of ports. Experience from previous earthquakes indicates that the connection between the pile and the wharf deck is a major source of damage during and earthquake. Previous studies indicate that although connections designed using current guidelines can maintain cyclic drift demands, they sustain damage and initiate strength deterioration, even at low levels of drift. Therefore, there is an interest in improving the performance of precast pile connections. A study to improve the performance of pile-wharf connections, part of the NEES-GC Seismic Risk Mitigation of Ports, was undertaken to develop damage-resistant connection. The results of the study and associated performance tools are summarized. To mitigate the pile and deck damage, several structural concepts were evaluated including (1) intentional debonding of the headed reinforcing bars, (2) supplemental rotation capacity through the addition of a cotton duck bearing pad and (3) supplemental material to sustain the lateral deformations while minimizing deck damage. The test results show minimal damage and strength loss relative to current practice and achieving performance-based design objectives. These results have been combined with prior test results on connections. By separating the connection responses by categories, individual connection-rotation based fragility curves have been developed for three repair-specific damage states. These curves would be appropriate for performance-based evaluation of older, current, or innovative connections in port construction.
- 24 June 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-13
Seismic Performance of Pile-Wharf Connections
Pile-supported marginal wharves are a critical infrastructure component of ports. Experience from previous earthquakes indicates that the connection between the pile and the wharf deck is a major source of damage during and earthquake. Previous studies indicate that although connections designed using current guidelines can maintain cyclic drift demands, they sustain damage and initiate strength deterioration, even at low levels of drift. Therefore, there is an interest in improving the performance of precast pile connections. A study to improve the performance of pile-wharf connections, part of the NEES-GC Seismic Risk Mitigation of Ports, was undertaken to develop damage-resistant connection. The results of the study and associated performance tools are summarized. To mitigate the pile and deck damage, several structural concepts were evaluated including (1) intentional debonding of the headed reinforcing bars, (2) supplemental rotation capacity through the addition of a cotton duck bearing pad and (3) supplemental material to sustain the lateral deformations while minimizing deck damage. The test results show minimal damage and strength loss relative to current practice and achieving performance-based design objectives. These results have been combined with prior test results on connections. By separating the connection responses by categories, individual connection-rotation based fragility curves have been developed for three repair-specific damage states. These curves would be appropriate for performance-based evaluation of older, current, or innovative connections in port construction.
- 26 April 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
A Practical Model for Beam-Column Connection Behavior in Reinforced Concrete Frames
Traditional as well as performance-based seismic design requires accurate simulation of building response to determine component deformation and load demands. This is particularly challenging for reinforced concrete structures in which concrete cracking prior to yield may change component stiffnesses substantially and for existing concrete structures in which inadequate design details may result in component strength loss prior to yield. In this study analytical models, which are practical for use in design and compatible with commercial software such as SAP2000, are developed for one type of concrete component: planar interior beam-column joints. A dataset comprising 45 joint sub-assemblage tests is used for model development. First, a simple, center-line model is proposed for elastic analysis in which the beam-column joint region is modeled as semi-rigid. Experimental data are used to determine the joint stiffness that minimizes the error in predicted inter-story drift and the new ASCE 41 recommendations are evaluated. A second model is developed for use in a nonlinear pushover-type analysis. For this model, joint flexibility and beam flexural response are represented by plastic hinges at beam ends. A simple empirically-based model is used to determine, on the basis of joint shear stress demand and bond stress demand within the joint, if system response will be ductile or brittle. A joint shear strain limit determines when strength loss will occur in brittle joints. For ductile joints, the behavior of the sub-assemblage is dominated by the nonlinear response of the beams.
- 26 April 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
A Practical Model for Beam-Column Connection Behavior in Reinforced Concrete Frames
Traditional as well as performance-based seismic design requires accurate simulation of building response to determine component deformation and load demands. This is particularly challenging for reinforced concrete structures in which concrete cracking prior to yield may change component stiffnesses substantially and for existing concrete structures in which inadequate design details may result in component strength loss prior to yield. In this study analytical models, which are practical for use in design and compatible with commercial software such as SAP2000, are developed for one type of concrete component: planar interior beam-column joints. A dataset comprising 45 joint sub-assemblage tests is used for model development. First, a simple, center-line model is proposed for elastic analysis in which the beam-column joint region is modeled as semi-rigid. Experimental data are used to determine the joint stiffness that minimizes the error in predicted inter-story drift and the new ASCE 41 recommendations are evaluated. A second model is developed for use in a nonlinear pushover-type analysis. For this model, joint flexibility and beam flexural response are represented by plastic hinges at beam ends. A simple empirically-based model is used to determine, on the basis of joint shear stress demand and bond stress demand within the joint, if system response will be ductile or brittle. A joint shear strain limit determines when strength loss will occur in brittle joints. For ductile joints, the behavior of the sub-assemblage is dominated by the nonlinear response of the beams.
- 14 October 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Test of a Full Scale Concentrically Braced Frame with Multi-Story X-Bracing
This paper summarizes the results of a full scale, 2-story braced frame test that was performed at the NCREE Laboratory in Taiwan as part of a small group NEES research project, NSF CMS 0619161, "NEESR-SG International Hybrid Simulation of Tomorrow's Braced Frames," on concentrically braced frames. This is the first in a series of four large-scale tests that will be performed in Taiwan. The first test specimen is a full scale, 2-story, single bay braced frame in a multi-story X-brace configuration. The test has several goals. It will provide a first experimental examination of the multi-story X-brace system and of the midspan gusset plate connections. It will serve as a basis for calibrating nonlinear analytical models of braced frame behavior under development as part of the research. At the same time, it is a confirmation study for past research on corner gusset plate connections performed at the University of Washington. If conditions permit, the frame will be used for a second test with wide flange braces. Details, data and photos of the test frame during construction, preparation and testing are provided on the NCREE website: http://exp.ncree.org/cbf/. This paper was written immediately after completion of the test on December 11, 2007 and includes a summary of the design and analysis of the frame and the initial test results.
- 14 October 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Test of a Full Scale Concentrically Braced Frame with Multi-Story X-Bracing
This paper summarizes the results of a full scale, 2-story braced frame test that was performed at the NCREE Laboratory in Taiwan as part of a small group NEES research project, NSF CMS 0619161, "NEESR-SG International Hybrid Simulation of Tomorrow's Braced Frames," on concentrically braced frames. This is the first in a series of four large-scale tests that will be performed in Taiwan. The first test specimen is a full scale, 2-story, single bay braced frame in a multi-story X-brace configuration. The test has several goals. It will provide a first experimental examination of the multi-story X-brace system and of the midspan gusset plate connections. It will serve as a basis for calibrating nonlinear analytical models of braced frame behavior under development as part of the research. At the same time, it is a confirmation study for past research on corner gusset plate connections performed at the University of Washington. If conditions permit, the frame will be used for a second test with wide flange braces. Details, data and photos of the test frame during construction, preparation and testing are provided on the NCREE website: http://exp.ncree.org/cbf/. This paper was written immediately after completion of the test on December 11, 2007 and includes a summary of the design and analysis of the frame and the initial test results.
- 14 October 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Improved Seismic Design of Concentrically Braced Frames and Gusset Plate Connections
Special concentrically braced frames (SCBFs) are economical and provide substantial lateral resistance and stiffness. They are frequently used in seismic design, since recent issues with steel moment resisting frames have increased their cost and raised doubts about their performance. Unfortunately SCBFs are not as well understood as many other structural system, because they rely on inelastic post-buckling of the brace during extreme seismic events. As a result, several research studies have been undertaken to better understand and improve SCBF seismic behavior. A research study has been in progress at the University of Washington (UW) to improve the seismic performance of SCBF gusset plate connections. To date more than 20 large-scale SCBF frames with gusset plate connections have been tested, and extensive analysis has been performed. This work is summarized, and the broad general conclusions from the experimental work are noted and demonstrated. The importance of connection stiffness and gusset plate welding and the relative performance of bolted vs. welded and tapered vs. rectangular gusset plates are shown. The results lead to recommended changes in the current design methods. In particular a modified method for assuring end rotational capacity for brace buckling is proposed. This method provides lighter more compact gusset plates, which develop greater inelastic deformation capacity from the frame and less secondary damage to framing members.
- 14 October 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 1-10
Improved Seismic Design of Concentrically Braced Frames and Gusset Plate Connections
Special concentrically braced frames (SCBFs) are economical and provide substantial lateral resistance and stiffness. They are frequently used in seismic design, since recent issues with steel moment resisting frames have increased their cost and raised doubts about their performance. Unfortunately SCBFs are not as well understood as many other structural system, because they rely on inelastic post-buckling of the brace during extreme seismic events. As a result, several research studies have been undertaken to better understand and improve SCBF seismic behavior. A research study has been in progress at the University of Washington (UW) to improve the seismic performance of SCBF gusset plate connections. To date more than 20 large-scale SCBF frames with gusset plate connections have been tested, and extensive analysis has been performed. This work is summarized, and the broad general conclusions from the experimental work are noted and demonstrated. The importance of connection stiffness and gusset plate welding and the relative performance of bolted vs. welded and tapered vs. rectangular gusset plates are shown. The results lead to recommended changes in the current design methods. In particular a modified method for assuring end rotational capacity for brace buckling is proposed. This method provides lighter more compact gusset plates, which develop greater inelastic deformation capacity from the frame and less secondary damage to framing members.
- 1 June 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 134 (6) , 890-901
Improved Seismic Performance of Gusset Plate Connections
Current design practices use a strength-based design approach to design gusset plate connections in special concentrically braced frames (SCBFs), in which the expected tensile and compressive capacities of the brace are used to design the gusset plate and the weld used to connect the brace to the frame. To achieve brace end rotation, the gusset plate is sized using a linear offset rule, and large, uneconomical gusset plate connections may result. A research program was undertaken to improve the economy and performance of gusset plate connections. A new approach is proposed in which the gusset plate design is based on a balanced design approach in which the yield mechanisms of the brace are balanced with the yield mechanisms of the connection and the failure modes of the system to achieve a target yielding hierarchy and suppress unwanted failure modes. Full-scale one-story, one-bay frames were designed and tested to investigate the seismic performance of current and proposed design methods. In the test pro...
- 1 June 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 134 (6) , 890-901
Improved Seismic Performance of Gusset Plate Connections
Current design practices use a strength-based design approach to design gusset plate connections in special concentrically braced frames (SCBFs), in which the expected tensile and compressive capacities of the brace are used to design the gusset plate and the weld used to connect the brace to the frame. To achieve brace end rotation, the gusset plate is sized using a linear offset rule, and large, uneconomical gusset plate connections may result. A research program was undertaken to improve the economy and performance of gusset plate connections. A new approach is proposed in which the gusset plate design is based on a balanced design approach in which the yield mechanisms of the brace are balanced with the yield mechanisms of the connection and the failure modes of the system to achieve a target yielding hierarchy and suppress unwanted failure modes. Full-scale one-story, one-bay frames were designed and tested to investigate the seismic performance of current and proposed design methods. In the test pro...