DDDat Duthinh

Dat Duthinh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dat Duthinh has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Adam L. Pintar

    National Institute of Standards and Technology, Engineering Laboratory, Gaithersburg, MD 20899; {dat.duthinh, jianghua.ke, marc.levitan, sejun.park, long.phan, liang.shi, emil.simiu, donghun.yeo}@nist.gov

    2 shared publications
  • DongHun Yeo

    National Institute of Standards and Technology, Engineering Laboratory, Gaithersburg, MD 20899; {dat.duthinh, jianghua.ke, marc.levitan, sejun.park, long.phan, liang.shi, emil.simiu, donghun.yeo}@nist.gov

    2 shared publications
  • Emil Simiu

    National Institute of Standards and Technology, Engineering Laboratory, Gaithersburg, MD 20899; {dat.duthinh, jianghua.ke, marc.levitan, sejun.park, long.phan, liang.shi, emil.simiu, donghun.yeo}@nist.gov

    2 shared publications
  • Bradley F. Coffman

    Structural Engineer, Structural Consultants and Associates, Sugar Land, TX 77478

    1 shared publication
  • Chiara Crosti

    Structural and Geotechnical Engineering Department, University of Rome, La Sapienza, via Eudossiana, 18, Rome00184, Italy

    1 shared publication
  • Emil Simiu

    Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, USA

    1 shared publication

Latest Publications

  • Recent and Current Wind Engineering Research at the National Institute of Standards and Technology

    by Dat Duthinh, Jianghua Ke, Marc L. Levitan, Sejun Park, Long T. Phan, Adam L. Pintar, Liang Shi, Emil Simiu, DongHun Yeo

    This paper presents a brief review of recent and current NIST research on wind effects on structures aimed to improve and modernize current standard provisions and design practices and achieve a more resilient built environment in regions subjected to significant wind loads. The review covers research on the development of the contiguous United States wind maps included in Standard ASCE 7-16 to replace earlier maps, according to which the extreme wind climate is the same throughout most of the U.S. territory: development of wind load factors for use in wind tunnel procedures and the need to change the ISO 80% percentage point for the design peak pressure coefficients by a 57% percentage point; estimation on non-Gaussian peaks using the peaks-over-threshold two-dimensional Poisson process; codification of pressures on components and cladding; development of computational wind engineering (CWE) algorithms aimed to achieve numerical tools for use in structural engineering practice within the next decade; progress in tornado hazard mapping and tornado resistant design; and joint wind, storm surge, and wave hazards and their combined effects on structures.

  • Wind Load Factors for Use in the Wind Tunnel Procedure

    by Emil Simiu, Adam L. Pintar, Dat Duthinh, DongHun Yeo

    Published standards may be incomplete because they provide no guidance on wind load factors appropriate for use with the wind tunnel procedure. The purpose of this paper is to contribute to such guidance. Based on a classical definition of wind load factors as functions of uncertainties in the micrometeorological, wind climatological, aerodynamics, and structural dynamics elements that determine wind loads, the paper presents a simple, straightforward approach that allows practitioners to use appropriate wind load factors applicable when those uncertainties are either the same as or different from those assumed in the standard. Illustrations of the approach are presented for a variety of cases of practical interest. In estimating design wind loads, the various uncertainties should not be accounted for in isolation, for example, by specifying peak pressure coefficients with percentage points higher than those corresponding to their expected values. Rather, to achieve risk-consistent designs, the uncertainties should be accounted for collectively, in terms of their joint effect on the design wind loading. The design wind effect is equal to the estimated expectation of the peak wind effect times a load factor that, in most cases, is not significantly different from the load factor explicitly or implicitly specified in the standard. Notably, the load factor is not affected significantly by errors associated with interpolations required in typical database-assisted design applications. However, if the available wind speed records are several times shorter than 20 to 30 years, for example, the wind load factors increase by approximately 15%.


  • Instability of steel gusset plates in compression

    by Chiara Crosti, Dat Duthinh

    As a result of the structural failure of the I-35W Bridge in Minneapolis in 2007, the Federal Highway Administration (FHWA) issued guidelines for the load rating of gusset plates and recommended that the capacity of these plates on non-redundant steel truss bridges be verified. The purpose of this study is to examine the buckling behaviour of steel gusset plates in greater detail, accounting for parameters that were not explicitly included in the guidelines, such as initial deformations of the gusset plate, stiffness of the framing members, load distribution from the framing members to the plate and load eccentricity. For this purpose, a finite-element model of a gusset plate was developed and verified against experimental measurements. Results show that, for in-plane compressive loads with no moment and no eccentricity, the FHWA guidelines for load rating are conservative and safe for initial out-of-plane deformations up to one plate thickness.


  • Wind Effects on Low-Rise Metal Buildings: Database-Assisted Design versus ASCE 7-05 Standard Estimates

    by Bradley F. Coffman, Joseph A. Main, Dat Duthinh, Emil Simiu

    Peak bending moments are compared for a set of steel portal frames of industrial buildings in an open terrain calculated using database-assisted design (DAD) techniques and ASCE 7-05 Standard plots. The comparisons indicate that, depending on the building dimensions, the peak bending moments at the knee based on DAD techniques are generally larger by 10–30% than their counterparts based on the ASCE 7-05 plots. (In one case with a relatively steep roof slope of 26.6° the discrepancies exceed 70%.) For the buildings considered, the discrepancies increase with increasing roof slope and with increasing eave height.