SSShad M. Sargand

Shad M. Sargand

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shad M. Sargand has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of Rigid Pavement Rehabilitation Methods on I-86

    by Luis Juliàn Bendaña, Joel Ambrosino, Shad Sargand

    Experimental sections on Interstate 86 (I-86) in New York State were constructed and instrumented to evaluate the effectiveness of using various fracturing treatments applied to existing pavement before constructing unbonded concrete overlays. The treatments were untreated pavement, rubbilized pavement, and cracked and seated pavement. In each treatment, four slabs were instrumented with Linear Variable Differential Transformers (LVDTs), Vibrating Wire (VW) strain gauges, and Thermocouples (TCs) to collect long-term environmental data, and micromeasurement strain gauges to collect dynamic response data. A Weigh-in- Motion (WIM) unit and a weather station provided supplemental data on traffic and environmental conditions. Environmental data were recorded hourly and used to determine thermal effects on slab shape, strain, and stress. Dynamic response data were collected during nondestructive testing with falling weight deflectometers (FWD) in July 2006, November 2006, and March 2007. A comparison of the environmental effects on the slabs over the three treatments suggests that the untreated section experiences the largest strains and stresses, and is thus more likely to be subject to future distress in the form of topdown cracking. The dynamic response data were comparable for all sections, with the strains the least in the untreated section. However, the maximum dynamic strains were generally much lower than the maximum environmental strains, suggesting that the environmental factors will be more important in determining the relative longevity of the pavement over each treatment.

  • Finite Element Investigation of Corrugated Steel Pipe with Extreme Corrosion under Shallow Cover

    by Shad Sargand, Fouad Al, Husam Hussein, Issam Khoury

    Across the United States, a large number of corrugated steel pipes, installed three or four decades ago, are approaching the end of their useful | POSTER

  • Influence of Nonuniform Box Beam Dimensions and Bridge Transverse Slope on Environmentally Induced Stresses in Adjacent Box Beam Bridges

    by Rana Mutashar, Shad Sargand, Issam Khoury, Fouad T. Al Rikabi

    The service life of adjacent box beam bridges is curtailed by the corrosion of reinforcement in the girders and spalling of concrete. This damage is attributed primarily to infiltration of water and chemical agents through longitudinal cracks in the shear keys. However, there are two other possible factors that can lead to water penetration of the bridge structure and eventual failure in box beam bridges: nonuniform box beam dimensions and bridge transverse slope. No study has been conducted to evaluate the effects of these two factors on induced stresses in adjacent box beam bridges. Typically, box girders are placed together with a transverse slope to facilitate drainage, which creates contact areas along just the bottom edges of adjacent girders. Additionally, for girders with nonuniform dimensions, even if within beam dimension tolerance, the contact between adjacent beams may be created at isolated spots. Measurements made at a box beam fabrication site verified inconsistency of beam dimensions. Three-dimensional finite-element models of composite and noncomposite single-span skew-adjacent box beam bridges were created to determine the stresses induce at the contact areas under environmental load conditions. The finite-element model was calibrated and validated in terms of the stresses in tie bars using experimental temperature profiles (uniform with and without temperature gradient). Two models were analyzed; the first model represented the contact areas generated due to drainage slope and the second one represented nonuniform beam dimensions using realistic input data. Under uniform and temperature gradient conditions, the models showed that contact stresses exceeded the concrete design strength at certain spots along the beams’ length. For girders with full flat contact, the contact stresses were noted to be less than the concrete strength. Additionally, the results of the analysis showed the contact stresses were reduced when modeling a bridge with a reinforced concrete deck. Moreover, the skew geometry showed a significant effect on the distribution of stresses at contact zones. Furthermore, the finite-element failure mode was compared with past research in terms of the locations of the greatest deterioration, and good agreement was found. Based on the results, it is recommended in this study to construct box beam bridges with enough spacing between the beams to ensure that no contact occurs between them; it is also recommended to manufacture box beams with high levels of accuracy.


  • Load Capacity of Corrugated Steel Pipe with Extreme Corrosion under Shallow Cover

    by Shad M. Sargand, Issam Khoury, Husam H. Hussein, Teruhisa Masada

    Across the United States, a large number of corrugated steel pipes, installed three or four decades ago, are approaching the end of their useful service life. In many cases, these aging drainage structures are having significant degrees of metal loss over their inverts due to conveyance of abrasive surface water, which can be acidic in some regions. A metal culvert under Coopermill Road near Zanesville in Muskingum County, Ohio, was selected for replacement based on its advanced level of invert metal loss. Before its replacement, invert paving was done in the half of the culvert toward its outlet end. The other half toward the inlet end was left untreated. With the concrete fully cured, each half of the culvert was instrumented with strain gauges and string potentiometers. Each half was tested under an external load of up to 267 kN (60 kip) placed over the crown. The strains and deflections were measured from the sensors, and the corresponding stresses, thrusts, and bending moments were computed. Despite the highly deteriorated conditions, the culvert structure supported a load considerably larger than the legal limit of 80 kN (18 kip). The invert-paved section of the culvert responded to the load with smaller strains, deflections, and thrusts and moments. The stresses at the interface of the steel culvert and the poured concrete treatment were not very large.


  • Thin-Walled Steel Fiber Reinforced Concrete Pipes Performance under Three-Edge Bearing Load

    by Fouad T. Al Rikabi, Shad M. Sargand, Joh Kurdziel, Husam H. Hussein

    Steel fibers have been used recently in concrete pipe mix in attempt to reduce or eliminate the need for steel reinforced cage, which could reduce the production cost significantly and enhance the concrete pipe resistance for shear and radial failures. However, producing pipe with wall thickness specified by ASTM C76 may not be practical as buried pipes could carry more loads through soil structure interaction. The objective of this study is to evaluate the performance of concrete pipe with diameter of 1200 mm and reduced thickness to 50% of that specified by ASTM standard. The pipe was reinforced using hooked end steel fibers with a dosage of 9 kg/m3. The pipe was instrumented using string transducers to measure the horizontal and vertical deflections. Also, strain gauges mounted on the inner crown, inner springline, outer springline, and inner invert were used to monitor the strain response. The pipe was tested under three-edge bearing load in accordance with ASTM standard. The tested pipe experienced flexural failure as the cracks propagated longitudinally at the high-tension zones. Other failure modes such as radial and shear associated with large pipe diameters were not observed. Also, the tested pipe surpassed the minimum deflection ratio specified for the flexible pipe, which is 2% of the internal diameter. The presence of steel fiber increased the strain capacity of the concrete pipe prior to cracks appearing on pipe wall surface. The tested pipe could be used for the gravity pipe applications.


  • Accelerated Degradation Test on Coating Materials for Steel Pipes

    by Johnnatan Garcia-Ruiz, Shad Sargand, Teruhisa Masada

    Between 2015 and 2016, as part of a study assessing the Ohio Department of Transportation's conduit service life prediction methodology, a team of researchers from Ohio University evaluated the resistance to abrasion of different coating materials, used to extend the service life of corrugated steel pipes (CSP). Specimens of polymeric coated, bituminous coated, aluminized, and galvanized steel plates were subjected to an accelerated degradation test. The test was performed based on the ASTM A926-03(2014) standard, using a variation proposed to overcome its limited industry use due to limited availability of the required equipment. The variation consisted on using a modified Los Angeles abrasion machine instead of the unavailable machine required by the standard. Although the mentioned limitation led to the standard being withdrawn from the ASTM later in 2016; the modified equipment used in this study produced results that suggests it could be an alternative method for any research group in the industry wanting to evaluate the resistance of protective coatings used on CSP. In this test, the polymeric coating proved to be the most durable treatment, followed in order by bituminous coating, aluminized coating, and galvanized coating.


  • Material Properties of Synthetic Fiber–Reinforced Concrete under Freeze-Thaw Conditions

    by Fouad T. Al Rikabi, Shad M. Sargand, Issam Khoury, Husam H. Hussein

    For decades, synthetic fibers have been utilized to improve the performance of concrete structures by enhancing the flexural strength, modulus of elasticity, and other mechanical properties of concrete. However, there are uncertainties about how synthetic fibers affect the coefficient of thermal expansion (CTE), dynamic modulus of elasticity, and flexural strength of the concrete under freeze-thaw cycles. This study was an investigation of the effect of temperature change on the mechanical properties of fiber-reinforced concrete, including CTE, dynamic modulus of elasticity, and flexural strength. Two types of synthetic fiber, polypropylene (PP) and polyvinyl alcohol (PVA) fibers, with three dosages for each type, 6, 7, and 9  kg/m3 , were studied. The CTE was obtained using the severe temperature range specified by AASHTO specifications for measuring thermal effects in concrete bridge superstructures. Up to 300 freeze-thaw cycles were applied to specimens, while mass loss, dynamic modulus of elasticity, flexural strength, and CTE were measured in accordance with ASTM protocols. Adding fiber to concrete enhanced the flexural strength, increased the flexibility, decreased the dynamic modulus of elasticity, and increased the CTE. Specimens reinforced with PP fiber showed more flexural strength and flexibility than those reinforced with PVA fiber. Polyvinyl alcohol fiber–reinforced specimens exhibited greater CTE values compared with those reinforced with PP fiber. The added synthetic fiber enhanced the concrete’s resistance to freeze-thaw cycles. The optimum fiber dosage appears to be 7  kg/m3 , which generally had the best performance in terms of flexural strength, dynamic modulus of elasticity, and CTE while best preserving structural integrity under repeated freezing and thawing.


  • Minimizing Ends’ Cracks of Skewed Pre-Tensioned Box Beam Concrete Girders

    by Rana Mutashar, Shad Sargand, Anwer Al-Jhayyish, Issam Khoury

    Precast pre-stressed box beam bridges are extensively used in short and medium span bridge design throughout the United States. Recently, skewed geometry and heavy pre-stressed box beams were developed. Field inspection of such beams indicated most of them experience vertical and inclined cracks within end regions of the box beam. The range of crack widths was within the limit that is required to be repaired before being used in the bridge construction. The depth of cracks was found to be very close to the tie rods and beam’s reinforcement. Field observation also indicated that cracks were more intensive at the acute corner than the obtuse corner. The beams with cracks form a durability concern, especially when the water and chemical agents filtrate through the cracks and reach the tie rods and strands. Therefore, a three-dimensional nonlinear finite element model was developed to simulate the behavior of the box girders after releasing strands. Case study girders surveyed during site visits were used for modeling and validating finite elements. The beams were modeled with actual material properties, geometry, and strands cutting sequence. The finite element results were validated with measured data in terms of crack locations and upward deflection. Two of the most appropriate crack-controlling techniques found in the literature were evaluated with finite element analysis: modification of beam design and debonding strands. The results of this study showed the modified girder design technique significantly minimize cracks at the top of the end zones if two strands with full pre-stressing forces were added around the vertical centerline of the top flange. A 35% level of strands’ debonding technique appeared to be effective in minimizing the maximum tensile strain at the beam’s ends. Debonding exterior strands was more effective on reducing tensile strain than debonding interior strands. The box beam with two strands at the top flange is recommended for implementation by skewed box beam design.