ESEric P. Steinberg

Eric P. Steinberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eric P. Steinberg has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of Temperature Distributions on Thermally Induced Behavior of UHPC Shear Key Connections of an Adjacent Precast Prestressed Concrete Box Beam Bridge

    by Ali A. Semendary, Eric P. Steinberg, Kenneth K. Walsh, Elné Barnard

    Recently, there has been a rapid increase in using ultrahigh-performance concrete (UHPC) in bridge connections due to its high compressive strength, pre- and postcracking tensile strengths, superior bond, and durability characteristics. However, the behavior of field-cast UHPC connections under temperature effects is not yet fully understood. Furthermore, the temperature distribution that produces the largest thermally induced stresses in UHPC connections is unknown. In this study, the thermally induced stresses in field-cast UHPC shear key connections in an adjacent precast prestressed concrete box beam bridge were investigated using field data as well as a three-dimensional finite-element (FE) model. The FE model was validated using field data and exhibited the ability to capture the behavior of the bridge. A new temperature distribution was noticed based on the data analysis. This temperature distribution has not yet been considered by professional bridge design specifications, although it produced the largest thermally induced stresses in UHPC connections and at the beam–key interface. The observed temperature distribution should be considered in the design of UHPC shear keys for these types of bridges.


  • Shape Optimization of UHPC Shear Keys for Precast, Prestressed, Adjacent Box-Girder Bridges

    by Husam H. Hussein, Shad M. Sargand, Eric P. Steinberg

    Adjacent box-girder bridges are a popular choice for short- to intermediate-span bridges in several states because they are easy, quick to build, and cost-effective. Although longitudinal shear keys filled with grout between the girders and transverse posttensioning (TPT) ties ensure a monolithic behavior for the bridge, the durability of longitudinal shear keys still concerns researchers and engineers. Ultrahigh-performance concrete (UHPC) has been adopted as a new grout material for connections between bridge components. However, there is not yet any guidance or specification on the design of UHPC shear key configuration for adjacent box-girder bridge connections. The aim of this study was to use experimental results and finite-element (FE) modeling of direct shear, flexural, and direct tension tests to optimize a UHPC shear key configuration. These models were calibrated and validated with laboratory experimental results previously published by the authors. The models, along with different shear key configurations, were used to investigate the load transfer through previously proposed connections. After comparing the simulated shear keys in terms of the maximum load capacity, the optimized shear key shape (Type OPT) was designed to obtain a desired balance between economy and strength effects. The results demonstrated the contribution of the shear key configuration to the joint strength, and suggest that Type OPT shear key significantly increased load transfer, resulting in an enhanced serviceability. Therefore, use of Type OPT shear keys in a bridge may reduce the number of transverse shear reinforcement bars required, which in turn would improve the constructability of the bridge and reduce material and construction costs.


  • Live-Load Moment-Distribution Factors for an Adjacent Precast Prestressed Concrete Box Beam Bridge with Reinforced UHPC Shear Key Connections

    by Ali A. Semendary, Eric P. Steinberg, Kenneth K. Walsh, Elné Barnard

    In this study, the live-load moment-distribution factors (LLMDFs) were evaluated for an adjacent precast prestressed concrete box beam bridge. The bridge used a new shear key configuration, which was grouted with ultrahigh performance concrete (UHPC) and contained noncontact lap-splice dowel bars. The bridge did not contain transverse tie rods, transverse posttensioning, intermediate diaphragms, or a composite deck. As newly developed shear key connections, the LLMDFs are not addressed in the current professional bridge design specifications. Therefore, the LLMDFs were evaluated using static truck load testing. A three-dimensional finite-element model was created and validated by using field results. After validation, the truck load designed by professional bridge standards was applied to the model, and the LLMDFs were evaluated. The results indicate that LLMDFs based on the professional bridge design specifications were conservative compared with the field results. Furthermore, the predicted LLMDFs by means of the professional bridge design specifications were also conservative when the finite-element model was loaded with a truck designed by these specifications and assuming full connectivity for the beams to act as a unit.


  • Evaluation of Ultra-High Performance Concrete Grout Performance under Longitudinal Shear

    by Husam H. Hussein, Shad M. Sargand, Fouad T. Al Rikabi, Eric P. Steinberg

    Precast pre-stressed adjacent box girders have become a preferred choice for constructing bridges of short to intermediate spans in several states. However, their shear keys often experience longitudinal cracks under a large number of load and thermal cycles. Ultra-high performance concrete (UHPC) has been recently proposed as an alternate grout material to fabricate shear keys that will not develop longitudinal cracks and enhance transverse load transfer between high strength concrete (HSC) girders. Due to the difference in the thermal expansion coefficients of HSC and UHPC, thermal cycles may induce longitudinal shear stresses at the interface between HSC and UHPC materials. The objective of the present research was to evaluate the performance of UHPC in shear keys using a longitudinal shear test to determine the cracking threshold and ultimate shear strength in the longitudinal direction. The test results showed that the average maximum shear capacity for the UHPC shear key exceeds that determined from past research for any other grout material and any shear key configuration. The enhanced shear strength of the UHPC shear key may have an impact on the analysis and design of UHPC connections in bridges to better withstand the thermal stresses between UHPC and HSC composite structures.


  • Modeling the Shear Connection in Adjacent Box-Beam Bridges with Ultrahigh-Performance Concrete Joints. I: Model Calibration and Validation

    by Husam H. Hussein, Kenneth K. Walsh, Shad M. Sargand, Fouad T. Al Rikabi, Eric P. Steinberg

    Recent research on ultrahigh-performance concrete (UHPC) for connection elements in highway bridges indicates an improvement in the performance of the overall bridge superstructure. However, there is limited information on the effect of the material and bond strength of the UHPC on the load transfer mechanism between adjacent box girders. A three-dimensional finite-element (FE) model was developed to study the interface between UHPC and high-strength concrete (HSC) highway bridge connections. The UHPC-HSC interface was modeled using traction-separation, damage initiation criteria, and damage evolution while taking into account adhesion, friction, and the nonlinear material behavior. Material properties were determined directly from laboratory testing, and the interface parameters were identified through model calibration using direct tension test results and friction coefficients reported in the previous work. The model was validated by simulating the laboratory tests conducted at the Federal Highway Administration (FHWA) Turner-Fairbank Highway Research Center (TFHRC), and good agreement between numerical and experimental results was obtained. Finally, numerical simulations of two adjacent box-girder models using the proposed interface parameters and other interface models from past research were compared, and the results highlight the importance of using a high-fidelity model to accurately represent the system behavior.


  • Early-Age Behavior of an Adjacent Prestressed Concrete Box-Beam Bridge Containing UHPC Shear Keys with Transverse Dowels

    by Ali A. Semendary, Kenneth K. Walsh, Eric P. Steinberg

    Adjacent precast prestressed concrete box-beam bridges have been used in the United States for many years and have performed well. However, the shear keys between adjacent box beams are susceptible to cracking, which can cause reflective cracks in an overlay or composite deck. The shear-key cracks have been observed shortly after casting and have developed as a result of thermal load, shrinkage, live load, or a combination of these factors. Little research has been done to investigate the early-age field behavior of these bridges. In this study, the early-age behavior of a bridge containing partial-depth shear keys grouted with ultra-high-performance concrete (UHPC) and equally spaced dowel bars was investigated. The bridge, which is the first adjacent box-beam bridge in the United States utilizing reinforced UHPC shear keys, was instrumented and monitored. This paper presents the early-age field results of the bridge during the first week after construction. The bridge performed well, with no cracking in the shear keys based on field observations and data analysis. Furthermore, it is shown that the transverse dowels play a role in helping to carry the transverse stresses in the key at the early age, before the UHPC has gained sufficient strength.


  • Evaluation of Transverse Tie Rods in a 50-Year-Old Adjacent Prestressed Concrete Box Beam Bridge

    by Eric P. Steinberg, Ali A. Semendary

    Adjacent prestressed concrete box beam bridges are one of the most popular bridges in the United States for short to medium spans. Recently, there has been concern about the structural capacity of these bridges as they age and show signs of deterioration. Unfortunately, limited research has been performed on the transverse ties because they are typically used for pulling the adjacent beam together during construction. Therefore, they are typically neglected in the overall performance of the bridge. Little, if any, information is known of the behavior and contribution of the transverse ties to load transfer and the ultimate capacity after failure of the longitudinal shear key joints. Instrumenting installed transverse tie rods has not been done in the past due to difficultly in accessing the rods, and no technique has been established to perform the installation of a sensor in the tie rods. In addition, instrumenting a tie rod that has already been installed from the fascia beam would only allow th...


  • Laboratory Evaluation of Ultrahigh-Performance Concrete Shear Key for Prestressed Adjacent Precast Concrete Box Girder Bridges

    by Husam H. Hussein, Shad M. Sargand, Fouad T. Al Rikabi, Eric P. Steinberg

    Precast adjacent box girder bridges have become a preferred solution in several states due to their simple structure, economy, and ease of construction. However, longitudinal cracks often appear along the shear keys between adjacent box girders. With its superior strength and durability, ultrahigh-performance concrete (UHPC) has been used as an alternative grout material to reduce shear key cracking and enhance load transfer. The objective of the present research was to evaluate the performance of UHPC in shear keys using direct shear, direct tension, and flexural tests. Also, this study determined the effectiveness and functionality of shear reinforcement bars by applying direct shear load on specimens with shear reinforcement. In the direct shear test, a steel frame was placed around the specimens to allow the shear key to experience pure shear force. The direct shear test established the cracking threshold and ultimate shear strength of each shear key with and without shear reinforcement bars. The test results show that the average maximum shear capacity for the UHPC shear key without shear reinforcement bars exceeded that determined from past research for any grout material and any shear key configuration. Furthermore, the average maximum shear capacity increased by a factor of 1.81 with shear reinforcement bars. The enhanced shear strength of the UHPC shear key may have an impact on the analysis and design of UHPC connections in bridges.


  • Interfacial Properties of Ultrahigh-Performance Concrete and High-Strength Concrete Bridge Connections

    by Husam H. Hussein, Kenneth K. Walsh, Shad M. Sargand, Eric P. Steinberg

    Recently, ultra-high performance concrete (UHPC) has been utilized in highway bridge connections, where its superior strength and durability help to reduce joint cracking and enhance transverse load transfer. According to the load and resistance factor design (LRFD) bridge design procedure specified by AASHTO, the strength of the connections is dependent on the adhesion and friction between the connected materials. The objective of the present research is to identify the adhesion value between UHPC and high-strength concrete (HSC) with varying degrees of roughness. To this end, UHPC-HSC specimens were tested in direct tension according to ASTM protocols, and the maximum tensile stress at failure was obtained. Test results show that the average maximum tensile stress for the UHPC-HSC specimens with a smooth interface exceeds that determined from past research for any degree of roughness. Furthermore, the average maximum tensile stress increases with the degree of roughness. The results from the dir...