Sherri Hutchens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sherri Hutchens has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bin Hu
Graduate Research Assistant, Indoor Environment Center, Dept. of Architectural Engineering, The Pennsylvania State Univ., 104 Engineering Unit A, University Park, PA 16802
1 shared publication- Brandolyn Thran
Assistant Professor, Dept. of Architectural Engineering, Sejong Univ., 98 Gunja-Dong, Gwangjin-Gu, Seoul 143-747, Korea
1 shared publication - James D. Freihaut
Department of Architectural Engineering, Penn State College of Engineering, University Park, PA 16802, USA
1 shared publication - Joseph Firrantello
Envinity, Inc., 25 Decibel Rd Suite 205, State College, PA 16801, USA
1 shared publication Ponkamon Aumpansub
Graduate Research Assistant, Indoor Environment Center, Dept. of Architectural Engineering, The Pennsylvania State Univ., 104 Engineering Unit A, University Park, PA 16802
1 shared publication- William P. Bahnfleth
Department of Architectural Engineering and Director of the Indoor Environment Center, The Pennsylvania State University, University Park, PA, USA
1 shared publication
Latest Publications
- 1 June 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 13 (2) , 84-94
Effects of HVAC System and Building Characteristics on Exposure of Occupants to Short-Duration Point Source Aerosol Releases
This paper presents results from the simulation of localized, short-duration bioaerosol releases in a hypothetical building similar to a dormitory or barracks using public domain multizone air flow and contaminant dispersion modeling software. The primary purpose of the modeling was to generate example exposure data to be used in the development of a comprehensive microbial risk assessment methodology. However, these results are also of intrinsic interest for what they reveal about the contribution of various building characteristics to risk from airborne contaminants. A variety of parameters were varied, including building construction, heating, ventilating, and air-conditioning (HVAC) system design, and release characteristics, among others. Results of these simulations demonstrate the variability of exposure possible under different scenarios and, more particularly, the impact that HVAC design decisions can have on risk. Although a single building and restricted set of scenarios was investigated, several general conclusions could be drawn regarding factors, such as HVAC zoning and filter maintenance, that intrinsically contribute to vulnerability reduction.
- 1 June 2007
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 13 (2) , 84-94
Effects of HVAC System and Building Characteristics on Exposure of Occupants to Short-Duration Point Source Aerosol Releases
This paper presents results from the simulation of localized, short-duration bioaerosol releases in a hypothetical building similar to a dormitory or barracks using public domain multizone air flow and contaminant dispersion modeling software. The primary purpose of the modeling was to generate example exposure data to be used in the development of a comprehensive microbial risk assessment methodology. However, these results are also of intrinsic interest for what they reveal about the contribution of various building characteristics to risk from airborne contaminants. A variety of parameters were varied, including building construction, heating, ventilating, and air-conditioning (HVAC) system design, and release characteristics, among others. Results of these simulations demonstrate the variability of exposure possible under different scenarios and, more particularly, the impact that HVAC design decisions can have on risk. Although a single building and restricted set of scenarios was investigated, several general conclusions could be drawn regarding factors, such as HVAC zoning and filter maintenance, that intrinsically contribute to vulnerability reduction.