    Robust multipoint water‐fat separation using fat likelihood analysis

    by Huanzhou Yu, Scott B. Reeder, Ann Shimakawa, Charles A. McKenzie, Jean H. Brittain

    Fat suppression is an essential part of routine MRI scanning. Multiecho chemical‐shift based water‐fat separation methods estimate and correct for Bo field inhomogeneity. However, they must contend with the intrinsic challenge of water‐fat ambiguity that can result in water‐fat swapping. This problem arises because the signals from two chemical species, when both are modeled as a single discrete spectral peak, may appear indistinguishable in the presence of Bo off‐resonance. In conventional methods, the water‐fat ambiguity is typically removed by enforcing field map smoothness using region growing based algorithms. In reality, the fat spectrum has multiple spectral peaks. Using this spectral complexity, we introduce a novel concept that identifies water and fat for multiecho acquisitions by exploiting the spectral differences between water and fat. A fat likelihood map is produced to indicate if a pixel is likely to be water‐dominant or fat‐dominant by comparing the fitting residuals of two different signal models. The fat likelihood analysis and field map smoothness provide complementary information, and we designed an algorithm (Fat Likelihood Analysis for Multiecho Signals) to exploit both mechanisms. It is demonstrated in a wide variety of data that the Fat Likelihood Analysis for Multiecho Signals algorithm offers highly robust water‐fat separation for 6‐echo acquisitions, particularly in some previously challenging applications. Magn Reson Med, 2011.


  • Open Access

    Estimation of liver T*2 in transfusion‐related iron overload in patients with weighted least squares T*2 IDEAL

    by Shreyas S. Vasanawala, Huanzhou Yu, Ann Shimakawa, Michael Jeng, Jean H. Brittain

    MRI imaging of hepatic iron overload can be achieved by estimating T2* values using multiple‐echo sequences. The purpose of this work is to develop and clinically evaluate a weighted least squares algorithm based on T2* Iterative Decomposition of water and fat with Echo Asymmetry and Least‐squares estimation (IDEAL) technique for volumetric estimation of hepatic T2* in the setting of iron overload. The weighted least squares T2* IDEAL technique improves T2* estimation by automatically decreasing the impact of later, noise‐dominated echoes. The technique was evaluated in 37 patients with iron overload. Each patient underwent (i) a standard 2D multiple‐echo gradient echo sequence for T2* assessment with nonlinear exponential fitting, and (ii) a 3D T2* IDEAL technique, with and without a weighted least squares fit. Regression and Bland–Altman analysis demonstrated strong correlation between conventional 2D and T2* IDEAL estimation. In cases of severe iron overload, T2* IDEAL without weighted least squares reconstruction resulted in a relative overestimation of T2* compared with weighted least squares. Magn Reson Med, 2011.