Robust multipoint water‐fat separation using fat likelihood analysis
Open Access
- 12 August 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (4) , 1065-1076
Abstract
Fat suppression is an essential part of routine MRI scanning. Multiecho chemical‐shift based water‐fat separation methods estimate and correct for Bo field inhomogeneity. However, they must contend with the intrinsic challenge of water‐fat ambiguity that can result in water‐fat swapping. This problem arises because the signals from two chemical species, when both are modeled as a single discrete spectral peak, may appear indistinguishable in the presence of Bo off‐resonance. In conventional methods, the water‐fat ambiguity is typically removed by enforcing field map smoothness using region growing based algorithms. In reality, the fat spectrum has multiple spectral peaks. Using this spectral complexity, we introduce a novel concept that identifies water and fat for multiecho acquisitions by exploiting the spectral differences between water and fat. A fat likelihood map is produced to indicate if a pixel is likely to be water‐dominant or fat‐dominant by comparing the fitting residuals of two different signal models. The fat likelihood analysis and field map smoothness provide complementary information, and we designed an algorithm (Fat Likelihood Analysis for Multiecho Signals) to exploit both mechanisms. It is demonstrated in a wide variety of data that the Fat Likelihood Analysis for Multiecho Signals algorithm offers highly robust water‐fat separation for 6‐echo acquisitions, particularly in some previously challenging applications. Magn Reson Med, 2011.Keywords
This publication has 26 references indexed in Scilit:
- JIGSAW: Joint Inhomogeneity Estimation via Global Segment Assembly for Water–Fat SeparationIEEE Transactions on Medical Imaging, 2011
- Water–fat separation with bipolar multiecho sequencesMagnetic Resonance in Medicine, 2008
- Multiresolution field map estimation using golden section search for water‐fat separationMagnetic Resonance in Medicine, 2008
- Two‐point dixon fat–water separation: Improving reliability and accuracy in phase correction algorithmsJournal of Magnetic Resonance Imaging, 2008
- Relaxation effects in the quantification of fat using gradient echo imagingMagnetic Resonance Imaging, 2008
- Joint estimation of water/fat images and field inhomogeneity mapMagnetic Resonance in Medicine, 2008
- A single breath‐hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overloadJournal of Magnetic Resonance Imaging, 2003
- Method for efficient fast spin echo Dixon imagingMagnetic Resonance in Medicine, 2002
- Multipoint dixon technique for water and fat proton and susceptibility imagingJournal of Magnetic Resonance Imaging, 1991
- Simple proton spectroscopic imaging.Radiology, 1984