Nitin Kumar Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nitin Kumar Sharma has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Saman Naghieh
Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK, S7N 5A9, Canada
3 shared publications - Xiongbiao Chen
Division of Biomedical Engineering, University of Saskatchewan, Canada
3 shared publications - M. D. Sarker
Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, S7N 5C5, Canada
2 shared publications - Abhinav Kumar
Division of Agricultural Engineering, IARI-ICAR, PUSA, New Delhi 110012, India
1 shared publication - Apoorv Rathi
Chair of Applied Mechanics, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen-Nuremberg, Bavaria 91058 Germany
1 shared publication Daniel X.B. Chen
57 campus Drive Saskatoon, SK S7N 5A9 Canada
1 shared publication
Latest Publications
- 13 May 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (9)
Micromechanisms of Cortical Bone Failure Under Different Loading Conditions
Bone being a hierarchical composite material has a structure varying from macro- to nanoscale. The arrangement of the components of bone material and the bonding between fibers and matrix gives rise to its unique material properties. In this study, the micromechanisms of cortical bone failure were examined under different loading conditions using scanning electron microscopy. The experimental tests were conducted in longitudinal and transverse directions of bone diaphysis under tensile as well as compressive loading. The results show that bone material has maximum stiffness under longitudinal tensile loading, while the strength is higher under transverse compressive loading. A reverse trend of compressive mechanical properties of bone is observed for longitudinal and transverse loading as compared to trends reported in the previous studies. Therefore, micromechanisms of cortical bone failure were analyzed for different loading conditions to reveal such type of behavior of cortical bone and to correlate bone microstructure with mechanical response of bone.
- 13 May 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (9)
Micromechanisms of Cortical Bone Failure Under Different Loading Conditions
Bone being a hierarchical composite material has a structure varying from macro- to nanoscale. The arrangement of the components of bone material and the bonding between fibers and matrix gives rise to its unique material properties. In this study, the micromechanisms of cortical bone failure were examined under different loading conditions using scanning electron microscopy. The experimental tests were conducted in longitudinal and transverse directions of bone diaphysis under tensile as well as compressive loading. The results show that bone material has maximum stiffness under longitudinal tensile loading, while the strength is higher under transverse compressive loading. A reverse trend of compressive mechanical properties of bone is observed for longitudinal and transverse loading as compared to trends reported in the previous studies. Therefore, micromechanisms of cortical bone failure were analyzed for different loading conditions to reveal such type of behavior of cortical bone and to correlate bone microstructure with mechanical response of bone.
- 1 October 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (1)
Assessment of Elastic-Plastic Fracture Behavior of Cortical Bone Using a Small Punch Testing Technique
The fracture properties of cortical bone are directly coupled to its complex hierarchical structure. The limited availability of bone material from many anatomic locations creates challenges for assessing the effect of bone heterogeneity and anisotropy on fracture properties. The small punch technique was employed to examine the fracture behavior of cortical bone in terms of area under the curve values obtained from load–load point displacement behavior. Fracture toughness of cortical bone was also determined in terms of J-toughness values obtained using a compact tension (CT) test. Area under the curve values obtained from the small punch test were correlated with the J-toughness values of cortical bone. The effects of bone density and compositional parameters on area under the curve and Jtoughness values were also analyzed using linear and multiple regression analysis. Area under the curve and J-toughness values are strongly and positively correlated. Bone density and %mineral content are positively correlated with both area under the curve and J-toughness values. The multiple regression analysis outcomes support these results. Overall, the findings support the hypothesis that area under the curve values obtained from small punch tests can be used to assess the fracture behavior of cortical bone.
- 1 October 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (1)
Assessment of Elastic-Plastic Fracture Behavior of Cortical Bone Using a Small Punch Testing Technique
The fracture properties of cortical bone are directly coupled to its complex hierarchical structure. The limited availability of bone material from many anatomic locations creates challenges for assessing the effect of bone heterogeneity and anisotropy on fracture properties. The small punch technique was employed to examine the fracture behavior of cortical bone in terms of area under the curve values obtained from load–load point displacement behavior. Fracture toughness of cortical bone was also determined in terms of J-toughness values obtained using a compact tension (CT) test. Area under the curve values obtained from the small punch test were correlated with the J-toughness values of cortical bone. The effects of bone density and compositional parameters on area under the curve and Jtoughness values were also analyzed using linear and multiple regression analysis. Area under the curve and J-toughness values are strongly and positively correlated. Bone density and %mineral content are positively correlated with both area under the curve and J-toughness values. The multiple regression analysis outcomes support these results. Overall, the findings support the hypothesis that area under the curve values obtained from small punch tests can be used to assess the fracture behavior of cortical bone.
- 5 March 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 141 (4)
Studies on the Stress-Strain Relationship Bovine Cortical Bone Based on Ramberg–Osgood Equation
Bone is a complex material that exhibits an amount of plasticity before bone fracture takes place, where the nonlinear relationship between stress and strain is of importance to understand the mechanism behind the fracture. This brief presents our study on the examination of the stress–strain relationship of bovine femoral cortical bone and the relationship representation by employing the Ramberg–Osgood (R–O) equation. Samples were taken and prepared from different locations (upper, middle, and lower) of bone diaphysis and were then subjected to the uniaxial tensile tests under longitudinal and transverse loading conditions, respectively. The stress–strain curves obtained from tests were analyzed via linear regression analysis based on the R–O equation. Our results illustrated that the R–O equation is appropriate to describe the nonlinear stress–strain behavior of cortical bone, while the values of equation parameters vary with the sample locations (upper, middle, and lower) and loading conditions (longitudinal and transverse).
- 5 March 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 141 (4)
Studies on the Stress-Strain Relationship Bovine Cortical Bone Based on Ramberg–Osgood Equation
Bone is a complex material that exhibits an amount of plasticity before bone fracture takes place, where the nonlinear relationship between stress and strain is of importance to understand the mechanism behind the fracture. This brief presents our study on the examination of the stress–strain relationship of bovine femoral cortical bone and the relationship representation by employing the Ramberg–Osgood (R–O) equation. Samples were taken and prepared from different locations (upper, middle, and lower) of bone diaphysis and were then subjected to the uniaxial tensile tests under longitudinal and transverse loading conditions, respectively. The stress–strain curves obtained from tests were analyzed via linear regression analysis based on the R–O equation. Our results illustrated that the R–O equation is appropriate to describe the nonlinear stress–strain behavior of cortical bone, while the values of equation parameters vary with the sample locations (upper, middle, and lower) and loading conditions (longitudinal and transverse).