Peter Usenik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peter Usenik has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Aleš Fidler
Department of Endodontics and Operative Dentistry, Faculty of Medicine University of Ljubljana Ljubljana Slovenia
2 shared publications - Boštjan Likar
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
2 shared publications - Franjo Pernuš
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
2 shared publications Boštjan Likar
University of Ljubljana, Faculty of Electrical Engineering, Tržaška 25, SI-1000 Ljubljana, Slovenia
1 shared publicationFranjo Pernuš
University of Ljubljana, Faculty of Electrical Engineering, Tržaška 25, SI-1000 Ljubljana, Slovenia
1 shared publicationMiran Bürmen
University of Ljubljana, Faculty of Electrical Engineering, Tržaška 25, SI-1000 Ljubljana, Slovenia
1 shared publication
Latest Publications
- 1 October 2014
- Published by Elsevier in Journal of Dentistry
- Vol. 42 (10) , 1242-1247
Near-infrared hyperspectral imaging of water evaporation dynamics for early detection of incipient caries
- 1 October 2014
- Published by Elsevier in Journal of Dentistry
- Vol. 42 (10) , 1242-1247
Near-infrared hyperspectral imaging of water evaporation dynamics for early detection of incipient caries
- 1 September 2012
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 66 (9) , 1067-1074
Automated Classification and Visualization of Healthy and Diseased Hard Dental Tissues by Near-Infrared Hyperspectral Imaging
Dental caries remains one of the most prevalent chronic diseases of modern society. The initial stages of dental caries are characterized by demineralization of enamel, resulting in subclinical lesions, which are difficult to diagnose. If detected early enough, such demineralization can be arrested and reversed by noninvasive means through well-established preventive measures, such as fluoride therapy, anti-bacterial therapy, or low intensity laser irradiation. Near-infrared (NIR) hyperspectral imaging is a promising new technique for early detection of dental caries based on distinct spectral features of healthy and diseased dental tissues. In this study, we apply NIR hyperspectral imaging to classify and visualize healthy and diseased dental tissues including enamel, dentin, calculus, enamel caries, and dentin caries. For this purpose, a standardized teeth database was constructed consisting of 12 extracted human teeth with different degrees of caries lesions imaged by an NIR hyperspectral system, X-ray, and digital color camera. The color and X-ray images of teeth were presented to a clinician expert for localization of the dental tissues and classification of pathological changes, thereby obtaining the gold standard. Principal component analysis (PCA) was used for multivariate local modeling of healthy and diseased dental tissues. Finally, the dental tissues were classified by employing multiple discriminant analysis. Good agreement was observed between the resulting cross-validated classification and the gold standard with the classification sensitivity and specificity exceeding 79.8% and 93.8%, respectively. This study clearly shows that the proposed automated classification and visualization method based on NIR hyperspectral imaging has considerable diagnostic potential.
- 1 September 2012
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 66 (9) , 1067-1074
Automated Classification and Visualization of Healthy and Diseased Hard Dental Tissues by Near-Infrared Hyperspectral Imaging
Dental caries remains one of the most prevalent chronic diseases of modern society. The initial stages of dental caries are characterized by demineralization of enamel, resulting in subclinical lesions, which are difficult to diagnose. If detected early enough, such demineralization can be arrested and reversed by noninvasive means through well-established preventive measures, such as fluoride therapy, anti-bacterial therapy, or low intensity laser irradiation. Near-infrared (NIR) hyperspectral imaging is a promising new technique for early detection of dental caries based on distinct spectral features of healthy and diseased dental tissues. In this study, we apply NIR hyperspectral imaging to classify and visualize healthy and diseased dental tissues including enamel, dentin, calculus, enamel caries, and dentin caries. For this purpose, a standardized teeth database was constructed consisting of 12 extracted human teeth with different degrees of caries lesions imaged by an NIR hyperspectral system, X-ray, and digital color camera. The color and X-ray images of teeth were presented to a clinician expert for localization of the dental tissues and classification of pathological changes, thereby obtaining the gold standard. Principal component analysis (PCA) was used for multivariate local modeling of healthy and diseased dental tissues. Finally, the dental tissues were classified by employing multiple discriminant analysis. Good agreement was observed between the resulting cross-validated classification and the gold standard with the classification sensitivity and specificity exceeding 79.8% and 93.8%, respectively. This study clearly shows that the proposed automated classification and visualization method based on NIR hyperspectral imaging has considerable diagnostic potential.
- 28 June 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (8) , 957-966
Automated tracking and analysis of phospholipid vesicle contours in phase contrast microscopy images
In this article, we propose a method for automated tracking and analysis of vesicle contours in video sequences acquired by phase contrast microscopy. The contour is determined in each frame of the selected video sequence by detecting the transition between the interior and exterior of the vesicle that is reflected in the image intensity gradients. The resulting contour points are represented in the polar coordinate system, i.e., with uniform angular sampling and with coordinates that originate from the vesicle center of mass, enabling the analysis of the vesicle shape and its membrane fluctuations. By analyzing artificial images with known ground-truth contours, the accuracy and precision of the proposed method was estimated to be 34.1 and 26.9 nm for image signal-to-noise ratio of 23 dB and pixel size of 35 nm, respectively. The proposed method was evaluated on quasi-spherical vesicles made up of different proportions of 1-Palmitoyl-2-Oleoyl-sn-Glycero-3-Phosphocholine (POPC) and cholesterol and exposed to different temperatures. The results show that the method is robust and efficient in terms of speed and quantitative description of vesicle fluctuations. The magnitude of vesicle membrane fluctuations increased with temperature, while the bending rigidity of the membrane was increasing for temperatures up to 20°C and decreasing for higher temperatures irrespective of the vesicle molecular structure.
- 28 June 2011
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (8) , 957-966
Automated tracking and analysis of phospholipid vesicle contours in phase contrast microscopy images
In this article, we propose a method for automated tracking and analysis of vesicle contours in video sequences acquired by phase contrast microscopy. The contour is determined in each frame of the selected video sequence by detecting the transition between the interior and exterior of the vesicle that is reflected in the image intensity gradients. The resulting contour points are represented in the polar coordinate system, i.e., with uniform angular sampling and with coordinates that originate from the vesicle center of mass, enabling the analysis of the vesicle shape and its membrane fluctuations. By analyzing artificial images with known ground-truth contours, the accuracy and precision of the proposed method was estimated to be 34.1 and 26.9 nm for image signal-to-noise ratio of 23 dB and pixel size of 35 nm, respectively. The proposed method was evaluated on quasi-spherical vesicles made up of different proportions of 1-Palmitoyl-2-Oleoyl-sn-Glycero-3-Phosphocholine (POPC) and cholesterol and exposed to different temperatures. The results show that the method is robust and efficient in terms of speed and quantitative description of vesicle fluctuations. The magnitude of vesicle membrane fluctuations increased with temperature, while the bending rigidity of the membrane was increasing for temperatures up to 20°C and decreasing for higher temperatures irrespective of the vesicle molecular structure.