David L. Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David L. Johnson has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Robert A. Lynch
Department of Occupational and Environmental Health, University of Oklahoma College of Public Health, Oklahoma City, OK
3 shared publicationsKenneth R. Mead
Division of Applied Research and Technology, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH
2 shared publicationsMargaret L. Phillips
Department of Occupational and Environmental Health, University of Oklahoma College of Public Health, PO Box 26901, Oklahoma City, OK 72126-0901, USA
2 shared publicationsAnthony T. Van
Department of Occupational and Environmental Health, University of Oklahoma College of Public Health, PO Box 26901, Oklahoma City, OK 72126-0901, USA
1 shared publicationBradley S. Stevenson
University of Oklahoma
1 shared publication- Casey W. Cooper
University of Oklahoma College of Public Health
1 shared publication
Latest Publications
- Open Access
- 8 February 2019
- Published by Springer Nature in Aerobiologia
- Vol. 35 (3) , 411-420
A comparison of air sampling methods for Clostridium difficile endospore aerosol
- 8 February 2019
- Published by Springer Nature in Aerobiologia
- Vol. 35 (3) , 411-420
Open AccessA comparison of air sampling methods for Clostridium difficile endospore aerosol
- 1 October 2017
- Vol. 80 (3) , 34-49
Persistence of Bowl Water Contamination during Sequential Flushes of Contaminated Toilets.
Toilets contaminated with infectious organisms are a recognized contact disease transmission hazard. Previous studies indicate that toilet bowl water can remain contaminated for several flushes after the contamination occurs. This study characterized contamination persistence over an extended series of flushes using both indicator particles and viable bacteria. For this study, toilets were seeded with microbe-size microbial surrogates and with Pseudomonas fluorescens or Clostridium difficile bacteria and flushed up to 24 times. Bowl water samples collected after seeding and after each flush indicated the clearance per flush and residual bowl water contaminant concentration. Toilets exhibited 3 + log10 contaminant reductions with the first flush, only 1-2 logs with the second flush, and less than 1 log thereafter. Contamination still was present 24 flushes post contamination. Clearance was modeled accurately by a two-stage exponential decay process. This study shows that toilet bowl water will remain contaminated many flushes after initial contamination, posing a risk of recurring environmental contamination and associated infection incidence.
- 1 October 2017
- Vol. 80 (3) , 34-49
Persistence of Bowl Water Contamination during Sequential Flushes of Contaminated Toilets.
Toilets contaminated with infectious organisms are a recognized contact disease transmission hazard. Previous studies indicate that toilet bowl water can remain contaminated for several flushes after the contamination occurs. This study characterized contamination persistence over an extended series of flushes using both indicator particles and viable bacteria. For this study, toilets were seeded with microbe-size microbial surrogates and with Pseudomonas fluorescens or Clostridium difficile bacteria and flushed up to 24 times. Bowl water samples collected after seeding and after each flush indicated the clearance per flush and residual bowl water contaminant concentration. Toilets exhibited 3 + log10 contaminant reductions with the first flush, only 1-2 logs with the second flush, and less than 1 log thereafter. Contamination still was present 24 flushes post contamination. Clearance was modeled accurately by a two-stage exponential decay process. This study shows that toilet bowl water will remain contaminated many flushes after initial contamination, posing a risk of recurring environmental contamination and associated infection incidence.
- Open Access
- 6 July 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (6) , 711-723
Experimental Evaluation of Respirable Dust and Crystalline Silica Controls During Simulated Performance of Stone Countertop Fabrication Tasks With Powered Hand Tools
Workers who fabricate stone countertops using hand tools are at risk of silicosis from overexposure to respirable crystalline silica. This study explored the efficacy of simple engineering controls that can be used for dust suppression during use of hand tools by stone countertop fabricators. Controlled experiments were conducted to measure whether wet methods and on-tool local exhaust ventilation (LEV) reduced respirable dust (RD) exposures during use of various powered hand tools on quartz-rich engineered stone. RD samples collected during edge grinding with a diamond cup wheel and a silicon carbide abrasive wheel were analyzed gravimetrically as well as by X-ray diffraction to determine silica content. A personal optical aerosol monitor was used simultaneously with the RD samples and also for rapid assessment of controls for polishing, blade cutting, and core drilling. On-tool LEV and sheet-flow-wetting were effective in reducing exposures, especially when used in combination. Sheet-flow-wetting with LEV reduced geometric mean exposures by as much as 95%. However, typical water-spray-wetting on a grinding cup was less effective when combined with LEV than without LEV. Mean silica content of RD samples from grinding operations was 53%, and respirable mass and silica mass were very highly correlated (r = 0.980). Optical concentration measures were moderately well correlated with gravimetric measures (r = 0.817), but on average the optical measures during a single trial using the factory calibration were only one-fifth the simultaneous gravimetric measures. Sheet-flow-wetting combined with on-tool LEV is an effective engineering control for reducing RD exposures during engineered stone edge grinding and blade cutting. On the other hand, addition of LEV to some water-spray-wetted tools may reduce the effectiveness of the wet method.
- 6 July 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (6) , 711-723
Open AccessExperimental Evaluation of Respirable Dust and Crystalline Silica Controls During Simulated Performance of Stone Countertop Fabrication Tasks With Powered Hand Tools
Workers who fabricate stone countertops using hand tools are at risk of silicosis from overexposure to respirable crystalline silica. This study explored the efficacy of simple engineering controls that can be used for dust suppression during use of hand tools by stone countertop fabricators. Controlled experiments were conducted to measure whether wet methods and on-tool local exhaust ventilation (LEV) reduced respirable dust (RD) exposures during use of various powered hand tools on quartz-rich engineered stone. RD samples collected during edge grinding with a diamond cup wheel and a silicon carbide abrasive wheel were analyzed gravimetrically as well as by X-ray diffraction to determine silica content. A personal optical aerosol monitor was used simultaneously with the RD samples and also for rapid assessment of controls for polishing, blade cutting, and core drilling. On-tool LEV and sheet-flow-wetting were effective in reducing exposures, especially when used in combination. Sheet-flow-wetting with LEV reduced geometric mean exposures by as much as 95%. However, typical water-spray-wetting on a grinding cup was less effective when combined with LEV than without LEV. Mean silica content of RD samples from grinding operations was 53%, and respirable mass and silica mass were very highly correlated (r = 0.980). Optical concentration measures were moderately well correlated with gravimetric measures (r = 0.817), but on average the optical measures during a single trial using the factory calibration were only one-fifth the simultaneous gravimetric measures. Sheet-flow-wetting combined with on-tool LEV is an effective engineering control for reducing RD exposures during engineered stone edge grinding and blade cutting. On the other hand, addition of LEV to some water-spray-wetted tools may reduce the effectiveness of the wet method.
- Open Access
- 17 October 2014
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 59 (1) , 122-126
Respirable Silica Dust Suppression During Artificial Stone Countertop Cutting
To assess the relative efficacy of three types of controls in reducing respirable silica exposure during artificial stone countertop cutting with a handheld circular saw. A handheld worm drive circular saw equipped with a diamond segmented blade was fitted with water supply to wet the blade as is typical. The normal wetted-blade condition was compared to (i) wetted-blade plus ‘water curtain’ spray and (ii) wetted-blade plus local exhaust ventilation (LEV). Four replicate 30-min trials of 6-mm deep, 3-mm wide cuts in artificial quartz countertop stone were conducted at each condition in a 24-m 3 unventilated tent. One dry cutting trial was also conducted for comparison. Respirable cyclone breathing zone samples were collected on the saw operator and analyzed gravimetrically for respirable mass and by X-ray diffraction for respirable quartz mass. Mean quartz content of the respirable dust was 58.5%. The ranges of 30-min mass and quartz task concentrations in mg m −3 were as follows—wet blade alone: 3.54–7.51 and 1.87–4.85; wet blade + curtain: 1.81–5.97 and 0.92–3.41; and wet blade + LEV: 0.20–0.69 and −3 mass and 44.6mg m −3 quartz. There was a statistically significant difference ( α = 0.05) between the wet blade + LEV and wet blade only conditions, but not between the wet blade + curtain and wet blade only conditions, for both respirable dust and respirable silica. Sawing with a wetted blade plus LEV reduced mean respirable dust and quartz task exposures by a factor of 10 compared to the wet blade only condition. We were unable to show a statistically significant benefit of a water curtain in the ejection path, but the data suggested some respirable dust suppression.
- 17 October 2014
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 59 (1) , 122-126
Open AccessRespirable Silica Dust Suppression During Artificial Stone Countertop Cutting
To assess the relative efficacy of three types of controls in reducing respirable silica exposure during artificial stone countertop cutting with a handheld circular saw. A handheld worm drive circular saw equipped with a diamond segmented blade was fitted with water supply to wet the blade as is typical. The normal wetted-blade condition was compared to (i) wetted-blade plus ‘water curtain’ spray and (ii) wetted-blade plus local exhaust ventilation (LEV). Four replicate 30-min trials of 6-mm deep, 3-mm wide cuts in artificial quartz countertop stone were conducted at each condition in a 24-m 3 unventilated tent. One dry cutting trial was also conducted for comparison. Respirable cyclone breathing zone samples were collected on the saw operator and analyzed gravimetrically for respirable mass and by X-ray diffraction for respirable quartz mass. Mean quartz content of the respirable dust was 58.5%. The ranges of 30-min mass and quartz task concentrations in mg m −3 were as follows—wet blade alone: 3.54–7.51 and 1.87–4.85; wet blade + curtain: 1.81–5.97 and 0.92–3.41; and wet blade + LEV: 0.20–0.69 and −3 mass and 44.6mg m −3 quartz. There was a statistically significant difference ( α = 0.05) between the wet blade + LEV and wet blade only conditions, but not between the wet blade + curtain and wet blade only conditions, for both respirable dust and respirable silica. Sawing with a wetted blade plus LEV reduced mean respirable dust and quartz task exposures by a factor of 10 compared to the wet blade only condition. We were unable to show a statistically significant benefit of a water curtain in the ejection path, but the data suggested some respirable dust suppression.
- 18 June 2013
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 47 (9) , 1047-1057
Aerosol Generation by Modern Flush Toilets
A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei “bioaerosols” were assessed. Monodisperse 0.25–1.9-μm fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m3 water closet (WC). Bowl water seeding was approximately 1012 particles/mL. Droplet nuclei were sampled onto 0.2-μm pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets 99% <5 μm. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms—splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei. Copyright 2013 American Association for Aerosol Research
- 18 June 2013
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 47 (9) , 1047-1057
Aerosol Generation by Modern Flush Toilets
A microbe-contaminated toilet will produce bioaerosols when flushed. We assessed toilet plume aerosol from high efficiency (HET), pressure-assisted high efficiency (PAT), and flushometer (FOM) toilets with similar bowl water and flush volumes. Total and droplet nuclei “bioaerosols” were assessed. Monodisperse 0.25–1.9-μm fluorescent microspheres served as microbe surrogates in separate trials in a mockup 5 m3 water closet (WC). Bowl water seeding was approximately 1012 particles/mL. Droplet nuclei were sampled onto 0.2-μm pore size mixed cellulose ester filters beginning 15 min after the flush using open-face cassettes mounted on the WC walls. Pre- and postflush bowl water concentrations were measured. Filter particle counts were analyzed via fluorescent microscopy. Bowl headspace droplet count size distributions were bimodal and similar for all toilet types and flush conditions, with 95% of droplets 99% <5 μm. Up to 145,000 droplets were produced per flush, with the high-energy flushometer producing over three times as many as the lower energy PAT and over 12 times as many as the lowest energy HET despite similar flush volumes. The mean numbers of fluorescent droplet nuclei particles aerosolized and remaining airborne also increased with flush energy. Fluorescent droplet nuclei per flush decreased with increasing particle size. These findings suggest two concurrent aerosolization mechanisms—splashing for large droplets and bubble bursting for the fine droplets that form droplet nuclei. Copyright 2013 American Association for Aerosol Research
- 1 March 2013
- Published by Elsevier in American Journal of Infection Control
- Vol. 41 (3) , 254-258
Lifting the lid on toilet plume aerosol: A literature review with suggestions for future research
- 1 March 2013
- Published by Elsevier in American Journal of Infection Control
- Vol. 41 (3) , 254-258
Lifting the lid on toilet plume aerosol: A literature review with suggestions for future research
- 1 March 2009
- Published by Elsevier in American Journal of Infection Control
- Vol. 37 (2) , 94-100
Containment effectiveness of expedient patient isolation units
- 1 March 2009
- Published by Elsevier in American Journal of Infection Control
- Vol. 37 (2) , 94-100
Containment effectiveness of expedient patient isolation units
- 4 August 2008
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 5 (10) , 656-663
Professional Judgment and the Interpretation of Viable Mold Air Sampling Data
Although mold air sampling is technically straightforward, interpreting the results to decide if there is an indoor source is not. Applying formal statistical tests to mold sampling data is an error-prone practice due to the extreme data variability. With neither established exposure limits nor useful statistical techniques, indoor air quality investigators often must rely on their professional judgment, but the lack of a consensus "decision strategy" incorporating explicit decision criteria requires professionals to establish their own personal set of criteria when interpreting air sampling data. This study examined the level of agreement among indoor air quality practitioners in their evaluation of airborne mold sampling data and explored differences in inter-evaluator assessments. Eighteen investigators independently judged 30 sets of viable mold air sampling results to indicate: "definite indoor mold source," "likely indoor mold source," "not enough information to decide," "likely no indoor mold source," or "definitely no indoor mold source." Kappa coefficient analysis indicated weak inter-observer reliability, and comparison of evaluator mean scores showed clear inter-evaluator differences in their overall scoring patterns. The responses were modeled on indicator "traits" of the data sets using a generalized, linear mixed model approach and showed several traits to be associated with respondents' ratings, but they also demonstrated distinct and divergent inter-evaluator response patterns. Conclusions were that there was only weak overall agreement in evaluation of the mold sampling data, that particular traits of the data were associated with the conclusions reached, and that there were substantial inter-evaluator differences that were likely due to differences in the personal decision criteria employed by the individual evaluators. The overall conclusion was that there is a need for additional work to rigorously explore the constellation of decision criteria, the weightings employed by individual practitioners, and the rationale under which criteria are adopted as first steps toward the larger goal of developing a consensus mold decision strategy.
- 4 August 2008
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 5 (10) , 656-663
Professional Judgment and the Interpretation of Viable Mold Air Sampling Data
Although mold air sampling is technically straightforward, interpreting the results to decide if there is an indoor source is not. Applying formal statistical tests to mold sampling data is an error-prone practice due to the extreme data variability. With neither established exposure limits nor useful statistical techniques, indoor air quality investigators often must rely on their professional judgment, but the lack of a consensus "decision strategy" incorporating explicit decision criteria requires professionals to establish their own personal set of criteria when interpreting air sampling data. This study examined the level of agreement among indoor air quality practitioners in their evaluation of airborne mold sampling data and explored differences in inter-evaluator assessments. Eighteen investigators independently judged 30 sets of viable mold air sampling results to indicate: "definite indoor mold source," "likely indoor mold source," "not enough information to decide," "likely no indoor mold source," or "definitely no indoor mold source." Kappa coefficient analysis indicated weak inter-observer reliability, and comparison of evaluator mean scores showed clear inter-evaluator differences in their overall scoring patterns. The responses were modeled on indicator "traits" of the data sets using a generalized, linear mixed model approach and showed several traits to be associated with respondents' ratings, but they also demonstrated distinct and divergent inter-evaluator response patterns. Conclusions were that there was only weak overall agreement in evaluation of the mold sampling data, that particular traits of the data were associated with the conclusions reached, and that there were substantial inter-evaluator differences that were likely due to differences in the personal decision criteria employed by the individual evaluators. The overall conclusion was that there is a need for additional work to rigorously explore the constellation of decision criteria, the weightings employed by individual practitioners, and the rationale under which criteria are adopted as first steps toward the larger goal of developing a consensus mold decision strategy.
- 22 February 2008
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 5 (4) , 271-277
An Efficient Analytical Method for Particle Counting in Evaluating Airborne Infectious Isolation Containment Using Fluorescent Microspheres
The containment performance of patient isolation enclosures, particularly expedient surge capacity enclosures, must be verified to protect health care providers and staff, other patients, and hospital visitors. Tracer gas methods are often used, but requirements for special equipment and training limit the technique's utility. A technologically simple yet accurate and precise particle-based technique is needed to measure the low count concentrations of escaping airborne particles that might be present outside an isolation enclosure. Reported here is the performance of such a technique employing micrometer-sized fluorescent polystyrene latex microspheres as a surrogate for pathogenic bioaerosols. Particles are released into the isolation enclosure, air is sampled inside and outside the room to capture airborne particles on 25 mm diameter filters, and the number of particles deposited on a filter is quantified using an optimized random field counting approach. The technique accurately estimates the number of surrogate bioaerosol particles on the filter, allowing calculation of the airborne particle concentrations inside and outside the enclosure, and the containment efficiency. This technique can be employed using generally available equipment and inexpensive supplies and also can minimize the number of particle counts that must be performed. The method is shown to be specific, sensitive, and accurate.
- 22 February 2008
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 5 (4) , 271-277
An Efficient Analytical Method for Particle Counting in Evaluating Airborne Infectious Isolation Containment Using Fluorescent Microspheres
The containment performance of patient isolation enclosures, particularly expedient surge capacity enclosures, must be verified to protect health care providers and staff, other patients, and hospital visitors. Tracer gas methods are often used, but requirements for special equipment and training limit the technique's utility. A technologically simple yet accurate and precise particle-based technique is needed to measure the low count concentrations of escaping airborne particles that might be present outside an isolation enclosure. Reported here is the performance of such a technique employing micrometer-sized fluorescent polystyrene latex microspheres as a surrogate for pathogenic bioaerosols. Particles are released into the isolation enclosure, air is sampled inside and outside the room to capture airborne particles on 25 mm diameter filters, and the number of particles deposited on a filter is quantified using an optimized random field counting approach. The technique accurately estimates the number of surrogate bioaerosol particles on the filter, allowing calculation of the airborne particle concentrations inside and outside the enclosure, and the containment efficiency. This technique can be employed using generally available equipment and inexpensive supplies and also can minimize the number of particle counts that must be performed. The method is shown to be specific, sensitive, and accurate.
- Open Access
- 1 January 2004
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 48 (1) , 13-20
Method-induced Misclassification for a Respirable Dust Sampled Using ISO/ACGIH/CEN Criteria
The single cut measurement of exposure to respirable dust is the accepted method of exposure classification in occupational hygiene. We previously showed that actual pulmonary tissue dose may be substantially different from the dose expected, or the indicated dose, based on measurements using current single cut methodologies. We now examine exposure misclassification of workers based on any single cut respirable dust measurement using the internationally accepted ISO/ACGIH/CEN single cut respirable dust measurement criteria. Hypothetical aerosols with 12 generalized size distributions typical of the method of aerosol generation (condensation, aged condensation, mechanical low energy, mechanical high energy and mixtures thereof) were assumed. Using previously reported models for sampler penetration and pulmonary deposition, Monte Carlo simulations of actual mass dose to pulmonary tissues in comparison to the dose estimate from an ideal respirable aerosol sampler were carried out. Measurement-based indicated doses were used to classify exposures into five exposure categories and these classifications were compared with the ‘true’ classifications from the dose-based exposure estimates. Misclassification rates were generally severe and were greatest for aerosols with mass median aerodynamic diameter (MMAD) < 1 µm (∼100%) and MMAD 5–15 µm (65–95%). Misclassification rates were moderate ( 15 µm. Misclassification rates for oral and nasal breathing at 750 and 1500 ml tidal volume and 15 breaths/min were similar for each aerosol examined.
- 1 January 2004
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 48 (1) , 13-20
Open AccessMethod-induced Misclassification for a Respirable Dust Sampled Using ISO/ACGIH/CEN Criteria
The single cut measurement of exposure to respirable dust is the accepted method of exposure classification in occupational hygiene. We previously showed that actual pulmonary tissue dose may be substantially different from the dose expected, or the indicated dose, based on measurements using current single cut methodologies. We now examine exposure misclassification of workers based on any single cut respirable dust measurement using the internationally accepted ISO/ACGIH/CEN single cut respirable dust measurement criteria. Hypothetical aerosols with 12 generalized size distributions typical of the method of aerosol generation (condensation, aged condensation, mechanical low energy, mechanical high energy and mixtures thereof) were assumed. Using previously reported models for sampler penetration and pulmonary deposition, Monte Carlo simulations of actual mass dose to pulmonary tissues in comparison to the dose estimate from an ideal respirable aerosol sampler were carried out. Measurement-based indicated doses were used to classify exposures into five exposure categories and these classifications were compared with the ‘true’ classifications from the dose-based exposure estimates. Misclassification rates were generally severe and were greatest for aerosols with mass median aerodynamic diameter (MMAD) < 1 µm (∼100%) and MMAD 5–15 µm (65–95%). Misclassification rates were moderate ( 15 µm. Misclassification rates for oral and nasal breathing at 750 and 1500 ml tidal volume and 15 breaths/min were similar for each aerosol examined.