Jun Kawai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jun Kawai has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Albin Sandelin
University of Copenhagen
2 shared publications - Alistair R. R. Forrest
Harry Perkins Institute of Medical Research, QEII Medical Centre and Centre for Medical Research, The University of Western Australia, Nedlands, Perth, WA 6009, Australia
2 shared publications - Christine Anne Wells
Department of Anatomy and Physiology, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Grattan Street, Parkville, Melbourne, Victoria 3010, Australia
2 shared publications - David Arthur Hume
Mater Research Institute-University of Queensland, Translational Research Institute, Woolloongabba, Brisbane, Qld 4102, Australia
2 shared publications - Harukazu Suzuki
RIKEN Center for Integrative Medical Sciences, Yokohama, Japan
2 shared publications - Hideya Kawaji
Research Center for Genome & Medical Sciences, Tokyo Metropolitan Institute of Medical Science, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 28 April 2026
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (6) , 858-867
Forensic Analysis of Fountain Pen Calligraphy– II . Real Evidence Analysis at the Public Prosecutor's Office
The present study is a report of the real forensic analysis of characters written by fountain pen(s) on two sheets of paper. One sheet is the calligraphy written by the victim of the Sayama incident. The other is number characters written with a fountain pen found on the lintel of the suspect's house. Chromium is detected between 65 and 112 ppm from Chinese characters of the victim's calligraphy. Chromium is not detected, that is, less than the detection limit (< 1 ppm), from the number characters written with the lintel pen. These ppm concentration values are the results of Soil‐FP (fundamental parameter) mode of the hand‐held X‐ray fluorescence (HH‐XRF) spectrometer used, which were around 100 ppm from the Chinese characters of model calligraphy written with Cr‐containing ink (Pilot Jet Blue ink), but less than 1 ppm for model calligraphy written with non‐Cr ink (Pilot Blue Black ink) as published in X‐Ray Spectrometry (DOI: 10.1002/xrs.70087 ). The real items of evidence were measured at the Public Prosecutor's Office in Tokyo by the same HH‐XRF spectrometer. The present XRF results prove that Mr. Ishikawa, who served 31 years in prison, was innocent, as he claimed until his death on March 11, 2025. The fountain pen of the victim was filled with Cr‐contained ink, but the pen which detectives found at the lintel of Ishikawa's house was filled with non‐Cr ink.
- 28 April 2026
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (6) , 858-867
Open AccessForensic Analysis of Fountain Pen Calligraphy– II . Real Evidence Analysis at the Public Prosecutor's Office
The present study is a report of the real forensic analysis of characters written by fountain pen(s) on two sheets of paper. One sheet is the calligraphy written by the victim of the Sayama incident. The other is number characters written with a fountain pen found on the lintel of the suspect's house. Chromium is detected between 65 and 112 ppm from Chinese characters of the victim's calligraphy. Chromium is not detected, that is, less than the detection limit (< 1 ppm), from the number characters written with the lintel pen. These ppm concentration values are the results of Soil‐FP (fundamental parameter) mode of the hand‐held X‐ray fluorescence (HH‐XRF) spectrometer used, which were around 100 ppm from the Chinese characters of model calligraphy written with Cr‐containing ink (Pilot Jet Blue ink), but less than 1 ppm for model calligraphy written with non‐Cr ink (Pilot Blue Black ink) as published in X‐Ray Spectrometry (DOI: 10.1002/xrs.70087 ). The real items of evidence were measured at the Public Prosecutor's Office in Tokyo by the same HH‐XRF spectrometer. The present XRF results prove that Mr. Ishikawa, who served 31 years in prison, was innocent, as he claimed until his death on March 11, 2025. The fountain pen of the victim was filled with Cr‐contained ink, but the pen which detectives found at the lintel of Ishikawa's house was filled with non‐Cr ink.
- 17 February 2026
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (4) , 634-638
Forensic Analysis of Fountain Pen Calligraphy‐I. A Model Study
The present study demonstrates that the X‐ray fluorescence (XRF) analysis of written characters on a sheet of paper (a model calligraphy) can identify the fountain pen. That is to say, the XRF analysis has the potential to prove the innocence of a person who served 31 years in prison (Sayama Incidence). He had maintained his innocence until his death. The XRF spectra in the present report were submitted to court before his death. A fountain pen was found in his house, and the pen was the evidence of murder committed by him. This is because the victim had the same kind of fountain pen. She wrote a calligraphy in a high school class and submitted it to the teacher, but she went missing late afternoon of that very day. The evidence has been kept in the Public Prosecutors Office. The defense attorney team has been permitted to examine the evidence, but the forensic analysis should be inside the Prosecutors Office. A handheld X‐ray fluorescence (HH‐XRF) spectrometer is selected. The calligraphy on a paper is mostly transparent for X‐rays, and several blank tests, as well as the backing of the calligraphy, are important in the present analysis. The calligraphy was sealed in a plastic bag when the XRF spectra were measured from outside of the plastic bag. The HH‐XRF can accomplish the necessary analyses non‐destructively within 1h including a control and several blank samples with a sufficient sensitivity of detection and sufficient accuracy of the quantification.
- 17 February 2026
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (4) , 634-638
Forensic Analysis of Fountain Pen Calligraphy‐I. A Model Study
The present study demonstrates that the X‐ray fluorescence (XRF) analysis of written characters on a sheet of paper (a model calligraphy) can identify the fountain pen. That is to say, the XRF analysis has the potential to prove the innocence of a person who served 31 years in prison (Sayama Incidence). He had maintained his innocence until his death. The XRF spectra in the present report were submitted to court before his death. A fountain pen was found in his house, and the pen was the evidence of murder committed by him. This is because the victim had the same kind of fountain pen. She wrote a calligraphy in a high school class and submitted it to the teacher, but she went missing late afternoon of that very day. The evidence has been kept in the Public Prosecutors Office. The defense attorney team has been permitted to examine the evidence, but the forensic analysis should be inside the Prosecutors Office. A handheld X‐ray fluorescence (HH‐XRF) spectrometer is selected. The calligraphy on a paper is mostly transparent for X‐rays, and several blank tests, as well as the backing of the calligraphy, are important in the present analysis. The calligraphy was sealed in a plastic bag when the XRF spectra were measured from outside of the plastic bag. The HH‐XRF can accomplish the necessary analyses non‐destructively within 1h including a control and several blank samples with a sufficient sensitivity of detection and sufficient accuracy of the quantification.
- 17 December 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (4) , 359-365
Sample Thickness Effect on Quantitative Analysis by Hand‐Held X‐Ray Fluorescence Spectrometers
Commercially available hand‐held X‐ray fluorescence (HH‐XRF) spectrometers have their own quantitative analysis software. When the elements Se and Cd in soil samples are measured and quantified, the calculated concentrations sometimes fail by a factor of 1/2 for Cd, although the values obtained for Se are accurate. This is because of the escape depth length of fluorescent X‐rays. Easy ways to overcome this problem are presented; two point calibration, or at least one point and one blank is enough. Problems associated with mercury evaporation from the sample is also discussed. Filter paper analysis is used as an example for the present work, and a five‐filter pile of ash‐less paper is concluded to have better sensitivity than a single paper filter analysis.
- 17 December 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (4) , 359-365
Sample Thickness Effect on Quantitative Analysis by Hand‐Held X‐Ray Fluorescence Spectrometers
Commercially available hand‐held X‐ray fluorescence (HH‐XRF) spectrometers have their own quantitative analysis software. When the elements Se and Cd in soil samples are measured and quantified, the calculated concentrations sometimes fail by a factor of 1/2 for Cd, although the values obtained for Se are accurate. This is because of the escape depth length of fluorescent X‐rays. Easy ways to overcome this problem are presented; two point calibration, or at least one point and one blank is enough. Problems associated with mercury evaporation from the sample is also discussed. Filter paper analysis is used as an example for the present work, and a five‐filter pile of ash‐less paper is concluded to have better sensitivity than a single paper filter analysis.
- 17 December 2024
- Published by Springer Nature
- p. 107-127
Other Spectroscopies: Terahertz and X-Ray Methods
- 17 December 2024
- Published by Springer Nature
- p. 107-127
Other Spectroscopies: Terahertz and X-Ray Methods
- Open Access
- 15 September 2024
- Published by Iron and Steel Institute of Japan in Tetsu-to-Hagane
- Vol. 110 (12) , 981-987
Polarization X-Ray Fluorescence Analysis by Milliwatt X-ray Tube
X-ray spectra scattered to 90°were measured for various scatterers of 5-mm thick B4C, acrylic, titanium, iron, zirconium, and lead plates, and their combinations such as B4C(5 mm thick) on acrylic plate (1 or 5 mm thick). The degree of polarization was estimated from the observed X-ray spectra at 0°and 90°. Using the best scatterer as an X-ray polarizer for each samples, polarization X-ray fluorescence (XRF) spectra of various samples such as cabtyre cable, book cover made of synthetic-resin, and steel making slag, compared with non-polarization XRF spectra. Toxic elements in some samples were more sensitive for polarized XRF, while other samples were more sensitive for non-polarized XRF. The reasons for such contradicted experimental results were discussed. Most of the measurements were performed by 15 mW X-ray tube power for polarization XRF, and by 3 mW for non-polarized XRF. The meanings of lowest power XRF measurements in the literature were also discussed. This kind of low power experiments may open the possibility of easy way of experiments, and non-invasive XRF analysis for cultural heritage.
- 15 September 2024
- Published by Iron and Steel Institute of Japan in Tetsu-to-Hagane
- Vol. 110 (12) , 981-987
Open AccessPolarization X-Ray Fluorescence Analysis by Milliwatt X-ray Tube
X-ray spectra scattered to 90°were measured for various scatterers of 5-mm thick B4C, acrylic, titanium, iron, zirconium, and lead plates, and their combinations such as B4C(5 mm thick) on acrylic plate (1 or 5 mm thick). The degree of polarization was estimated from the observed X-ray spectra at 0°and 90°. Using the best scatterer as an X-ray polarizer for each samples, polarization X-ray fluorescence (XRF) spectra of various samples such as cabtyre cable, book cover made of synthetic-resin, and steel making slag, compared with non-polarization XRF spectra. Toxic elements in some samples were more sensitive for polarized XRF, while other samples were more sensitive for non-polarized XRF. The reasons for such contradicted experimental results were discussed. Most of the measurements were performed by 15 mW X-ray tube power for polarization XRF, and by 3 mW for non-polarized XRF. The meanings of lowest power XRF measurements in the literature were also discussed. This kind of low power experiments may open the possibility of easy way of experiments, and non-invasive XRF analysis for cultural heritage.
- 3 April 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (1) , 54-57
Escape peaks of Ge detector in X‐ray fluorescence (XRF)
- 3 April 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (1) , 54-57
Escape peaks of Ge detector in X‐ray fluorescence (XRF)
- 16 December 2022
- Published by Springer Nature
- p. 63-105
Chemical Effects of Multiply Ionized Satellites
- 16 December 2022
- Published by Springer Nature
- p. 63-105
Chemical Effects of Multiply Ionized Satellites
- 16 December 2022
- Published by Springer Nature
- p. 135-161
Small-Size and Low-Power X-Ray Instruments