Jacob Filik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jacob Filik has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Mark Basham
The Rosalind Franklin Institute, Harwell Science & Innovation Campus, Didcot OX11 0QS, United Kingdom
3 shared publications - Sofia Diaz-Moreno
Diamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
3 shared publications - Andrew James
Physical Sciences Diamond Light Source Diamond House - Harwell Science and Innovation Campus Didcot OxfordshireOX11 0DE United Kingdom
2 shared publications - Christina Reinhard
Faculty of Science and Engineering, The University of Manchester, Oxford Road, Manchester M13 9PL, UK
2 shared publications - James J. Mudd
Diamond Light Source, Oxfordshire, UK
2 shared publications - John P. Sutter
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 1 February 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (1) , 12-27
The moving-beam diffraction geometry: the DIAD application of a diffraction scanning probe
Understanding the interactions between microstructure, strain, phase and material behavior is crucial in scientific fields such as energy storage, carbon sequestration and biomedical engineering. However, quantifying these correlations is challenging, as it requires the use of multiple instruments and techniques, often separated by space and time. The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is designed to address this challenge. DIAD allows its users to visualize internal structures (in two and three dimensions), identify compositional/phase changes and measure strain. It enables in situ and operando experiments that require spatially correlated information. DIAD provides two independent beams combined at one sample position, allowing `quasi-simultaneous' X-ray computed tomography and X-ray powder diffraction. A unique functionality of the DIAD configuration is the ability to perform `image-guided diffraction', where the micrometre-sized diffraction beam is scanned over the complete area of the imaging field of view without moving the specimen. This moving-beam diffraction geometry enables the study of fast-evolving and motion-susceptible processes and samples. Here, we discuss the novel moving-beam diffraction geometry, presenting the latest findings on the reliability of both the geometry calibration and the data-reduction routines used. We provide a comprehensive quantitative assessment of the moving-beam diffraction geometry implemented at the DIAD beamline, which will serve as a reference for beamline users. Our measurements confirm that diffraction is most sensitive to the moving-beam geometry for the conventional transmission geometry of the detector. The observed data confirm that the motion of the Kirkpatrick–Baez mirror coupled with a fixed-aperture slit results in a rigid translation of the beam probe, without affecting the angle of the incident-beam path to the sample. Our measurements demonstrate that a nearest-neighbor calibration can achieve the same accuracy as a self-calibrated geometry when the distance between the calibrated and probed sample regions is smaller than or equal to the beam spot size. The absolute error of the moving-beam diffraction geometry at DIAD with typical calibration setup remains below 0.01%, which is the accuracy we observe for the beamline with stable beam operation.
- 1 February 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (1) , 12-27
Open AccessThe moving-beam diffraction geometry: the DIAD application of a diffraction scanning probe
Understanding the interactions between microstructure, strain, phase and material behavior is crucial in scientific fields such as energy storage, carbon sequestration and biomedical engineering. However, quantifying these correlations is challenging, as it requires the use of multiple instruments and techniques, often separated by space and time. The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is designed to address this challenge. DIAD allows its users to visualize internal structures (in two and three dimensions), identify compositional/phase changes and measure strain. It enables in situ and operando experiments that require spatially correlated information. DIAD provides two independent beams combined at one sample position, allowing `quasi-simultaneous' X-ray computed tomography and X-ray powder diffraction. A unique functionality of the DIAD configuration is the ability to perform `image-guided diffraction', where the micrometre-sized diffraction beam is scanned over the complete area of the imaging field of view without moving the specimen. This moving-beam diffraction geometry enables the study of fast-evolving and motion-susceptible processes and samples. Here, we discuss the novel moving-beam diffraction geometry, presenting the latest findings on the reliability of both the geometry calibration and the data-reduction routines used. We provide a comprehensive quantitative assessment of the moving-beam diffraction geometry implemented at the DIAD beamline, which will serve as a reference for beamline users. Our measurements confirm that diffraction is most sensitive to the moving-beam geometry for the conventional transmission geometry of the detector. The observed data confirm that the motion of the Kirkpatrick–Baez mirror coupled with a fixed-aperture slit results in a rigid translation of the beam probe, without affecting the angle of the incident-beam path to the sample. Our measurements demonstrate that a nearest-neighbor calibration can achieve the same accuracy as a self-calibrated geometry when the distance between the calibrated and probed sample regions is smaller than or equal to the beam spot size. The absolute error of the moving-beam diffraction geometry at DIAD with typical calibration setup remains below 0.01%, which is the accuracy we observe for the beamline with stable beam operation.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
A multi-modal high pressure and high temperature reaction cell for combined x-ray spectroscopy, scattering, and imaging
A free-standing and compact reaction cell for combined in situ/operando x-ray spectroscopy, scattering, and imaging measurements at high pressures and high temperatures is described. The cell permits measurements under realistic operating conditions (up to 50 bar and 1000 °C), under static and flow conditions (up to 100 ml/min), over a wide range of hard x-ray energies, variable detection modes (transmission, fluorescence, and scattering), and at all angles of rotation. An operando XAS, x-ray fluorescence, x-ray computed tomography, and x-ray diffraction computed tomography case study on the reduction of a heterogeneous catalyst is presented to illustrate the performance of the reaction cell.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessA multi-modal high pressure and high temperature reaction cell for combined x-ray spectroscopy, scattering, and imaging
A free-standing and compact reaction cell for combined in situ/operando x-ray spectroscopy, scattering, and imaging measurements at high pressures and high temperatures is described. The cell permits measurements under realistic operating conditions (up to 50 bar and 1000 °C), under static and flow conditions (up to 100 ml/min), over a wide range of hard x-ray energies, variable detection modes (transmission, fluorescence, and scattering), and at all angles of rotation. An operando XAS, x-ray fluorescence, x-ray computed tomography, and x-ray diffraction computed tomography case study on the reduction of a heterogeneous catalyst is presented to illustrate the performance of the reaction cell.
- Open Access
- 1 August 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1276-1284
Web-CONEXS: an inroad to theoretical X-ray absorption spectroscopy
Accurate analysis of the rich information contained within X-ray spectra usually calls for detailed electronic structure theory simulations. However, density functional theory (DFT), time-dependent DFT and many-body perturbation theory calculations increasingly require the use of advanced codes running on high-performance computing (HPC) facilities. Consequently, many researchers who would like to augment their experimental work with such simulations are hampered by the compounding of nontrivial knowledge requirements, specialist training and significant time investment. To this end, we present Web-CONEXS, an intuitive graphical web application for democratizing electronic structure theory simulations. Web-CONEXS generates and submits simulation workflows for theoretical X-ray absorption and X-ray emission spectroscopy to a remote computing cluster. In the present form, Web-CONEXS interfaces with three software packages: ORCA, FDMNES and Quantum ESPRESSO, and an extensive materials database courtesy of the Materials Project API. These software packages have been selected to model diverse materials and properties. Web-CONEXS has been conceived with the novice user in mind; job submission is limited to a subset of simulation parameters. This ensures that much of the simulation complexity is lifted and preliminary theoretical results are generated faster. Web-CONEXS can be leveraged to support beam time proposals and serve as a platform for preliminary analysis of experimental data.
- 1 August 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1276-1284
Open AccessWeb-CONEXS: an inroad to theoretical X-ray absorption spectroscopy
Accurate analysis of the rich information contained within X-ray spectra usually calls for detailed electronic structure theory simulations. However, density functional theory (DFT), time-dependent DFT and many-body perturbation theory calculations increasingly require the use of advanced codes running on high-performance computing (HPC) facilities. Consequently, many researchers who would like to augment their experimental work with such simulations are hampered by the compounding of nontrivial knowledge requirements, specialist training and significant time investment. To this end, we present Web-CONEXS, an intuitive graphical web application for democratizing electronic structure theory simulations. Web-CONEXS generates and submits simulation workflows for theoretical X-ray absorption and X-ray emission spectroscopy to a remote computing cluster. In the present form, Web-CONEXS interfaces with three software packages: ORCA, FDMNES and Quantum ESPRESSO, and an extensive materials database courtesy of the Materials Project API. These software packages have been selected to model diverse materials and properties. Web-CONEXS has been conceived with the novice user in mind; job submission is limited to a subset of simulation parameters. This ensures that much of the simulation complexity is lifted and preliminary theoretical results are generated faster. Web-CONEXS can be leveraged to support beam time proposals and serve as a platform for preliminary analysis of experimental data.
- Open Access
- 29 January 2024
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 26 (6) , 753-763
Project M: investigating the effect of additives on calcium carbonate crystallisation through a school citizen science program
Crystallisation pathways of calcium carbonate are strongly influenced by the presence of additives. Through X-ray diffraction, samples made by the Project M Scientists reveal the effect of amino acid and related additives on the crystal structures of calcite and vaterite.
- 29 January 2024
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 26 (6) , 753-763
Open AccessProject M: investigating the effect of additives on calcium carbonate crystallisation through a school citizen science program
Crystallisation pathways of calcium carbonate are strongly influenced by the presence of additives. Through X-ray diffraction, samples made by the Project M Scientists reveal the effect of amino acid and related additives on the crystal structures of calcite and vaterite.
- Open Access
- 28 July 2022
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 55 (4) , 1011-1028
Calculating temperature-dependent X-ray structure factors of α-quartz with an extensible Python 3 package
The design of X-ray optics based on diffraction from crystals depends on the accurate calculation of the structure factors of their Bragg reflections over a wide range of temperatures. In general, the temperature dependence of the lattice parameters, the atomic positions and the atomic thermal vibrations is both anisotropic and nonlinear. Implemented here is a software package for precise and flexible calculation of structure factors for dynamical diffraction. α-Quartz is used as an example because it presents the challenges mentioned above and because it is being considered for use in high-resolution X-ray spectroscopy. The package is designed to be extended easily to other crystals by adding new material files, which are kept separate from the package's stable core. Python 3 was chosen as the language to allow the easy integration of this code into existing packages. The importance of a correct anisotropic treatment of the atomic thermal vibrations is demonstrated by comparison with an isotropic Debye model. Discrepancies between the two models can be as much as 5% for strong reflections and considerably larger (even to the level of 100%) for weak reflections. A script for finding Bragg reflections that backscatter X-rays of a given energy within a given temperature range is demonstrated. The package and example scripts are available on request. Also discussed, in detail, are the various conventions related to the proper description of chiral quartz.
- 28 July 2022
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 55 (4) , 1011-1028
Open AccessCalculating temperature-dependent X-ray structure factors of α-quartz with an extensible Python 3 package
The design of X-ray optics based on diffraction from crystals depends on the accurate calculation of the structure factors of their Bragg reflections over a wide range of temperatures. In general, the temperature dependence of the lattice parameters, the atomic positions and the atomic thermal vibrations is both anisotropic and nonlinear. Implemented here is a software package for precise and flexible calculation of structure factors for dynamical diffraction. α-Quartz is used as an example because it presents the challenges mentioned above and because it is being considered for use in high-resolution X-ray spectroscopy. The package is designed to be extended easily to other crystals by adding new material files, which are kept separate from the package's stable core. Python 3 was chosen as the language to allow the easy integration of this code into existing packages. The importance of a correct anisotropic treatment of the atomic thermal vibrations is demonstrated by comparison with an isotropic Debye model. Discrepancies between the two models can be as much as 5% for strong reflections and considerably larger (even to the level of 100%) for weak reflections. A script for finding Bragg reflections that backscatter X-rays of a given energy within a given temperature range is demonstrated. The package and example scripts are available on request. Also discussed, in detail, are the various conventions related to the proper description of chiral quartz.
- Open Access
- 22 October 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1985-1995
Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source
The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.
- 22 October 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (6) , 1985-1995
Open AccessBeamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source
The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.
- Open Access
- 3 September 2018
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 31 (5) , 21-26
Software Mapping Project with Nanopositioning Capabilities
- 3 September 2018
- Published by Taylor & Francis in Synchrotron Radiation News
- Vol. 31 (5) , 21-26
Open AccessSoftware Mapping Project with Nanopositioning Capabilities
- Open Access
- 1 June 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (4) , 998-1009
The Spectroscopy Village at Diamond Light Source
This manuscript presents the current status and technical details of the Spectroscopy Village at Diamond Light Source. The Village is formed of four beamlines: I18, B18, I20-Scanning and I20-EDE. The village provides the UK community with local access to a hard X-ray microprobe, a quick-scanning multi-purpose XAS beamline, a high-intensity beamline for X-ray absorption spectroscopy of dilute samples and X-ray emission spectroscopy, and an energy-dispersive extended X-ray absorption fine-structure beamline. The optics of B18, I20-scanning and I20-EDE are detailed; moreover, recent developments on the four beamlines, including new detector hardware and changes in acquisition software, are described.
- 1 June 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (4) , 998-1009
Open AccessThe Spectroscopy Village at Diamond Light Source
This manuscript presents the current status and technical details of the Spectroscopy Village at Diamond Light Source. The Village is formed of four beamlines: I18, B18, I20-Scanning and I20-EDE. The village provides the UK community with local access to a hard X-ray microprobe, a quick-scanning multi-purpose XAS beamline, a high-intensity beamline for X-ray absorption spectroscopy of dilute samples and X-ray emission spectroscopy, and an energy-dispersive extended X-ray absorption fine-structure beamline. The optics of B18, I20-scanning and I20-EDE are detailed; moreover, recent developments on the four beamlines, including new detector hardware and changes in acquisition software, are described.
- Top Cited PapersOpen Access
- 8 May 2017
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 50 (3) , 959-966
Processing two-dimensional X-ray diffraction and small-angle scattering data in DAWN 2
A software package for the calibration and processing of powder X-ray diffraction and small-angle X-ray scattering data is presented. It provides a multitude of data processing and visualization tools as well as a command-line scripting interface for on-the-fly processing and the incorporation of complex data treatment tasks. Customizable processing chains permit the execution of many data processing steps to convert a single image or a batch of raw two-dimensional data into meaningful data and one-dimensional diffractograms. The processed data files contain the full data provenance of each process applied to the data. The calibration routines can run automatically even for high energies and also for large detector tilt angles. Some of the functionalities are highlighted by specific use cases.
- 8 May 2017
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 50 (3) , 959-966
Top Cited PapersOpen AccessProcessing two-dimensional X-ray diffraction and small-angle scattering data in DAWN 2
A software package for the calibration and processing of powder X-ray diffraction and small-angle X-ray scattering data is presented. It provides a multitude of data processing and visualization tools as well as a command-line scripting interface for on-the-fly processing and the incorporation of complex data treatment tasks. Customizable processing chains permit the execution of many data processing steps to convert a single image or a batch of raw two-dimensional data into meaningful data and one-dimensional diffractograms. The processed data files contain the full data provenance of each process applied to the data. The calibration routines can run automatically even for high energies and also for large detector tilt angles. Some of the functionalities are highlighted by specific use cases.
- 10 September 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (24) , 5723-5729
Morphological analysis of vibrational hyperspectral imaging data
This study demonstrates the use of standard morphological image processing techniques to reduce the hyperspectral image data of samples, containing discrete particles or domains, to a single average spectrum per particle. The processing is automated and successful even when the particles are in contact. Focal Plane Array, Fourier transform infrared (FTIR) absorbance images of biological cells are used as an example dataset. The large number of spectra in the image (∼40 000) can be intelligently averaged to ∼100 mean spectra, approximately one per cell, greatly simplifying further analysis. As well as reducing the data, the morphological analysis provides useful information, such as the size of each cell, and allows every spectrum associated with each cell to be identified and analysed independently of the full dataset. Using these methods, combined with principal components analysis, consistent spectral differences are found between the spectra of the whole cells and a cell region approximately corresponding to the nucleus. These spectral differences compare well with previous IR measurements on whole CALU-1 cells and their isolated nuclei, but with a simpler sample preparation. The algorithm created to analyse the CALU-1 cells has been applied to a second cell line (NL20), which has a very different growth morphology, to demonstrate that this processing method is applicable to varied samples with little or no modification.
- 10 September 2012
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (24) , 5723-5729
Morphological analysis of vibrational hyperspectral imaging data
This study demonstrates the use of standard morphological image processing techniques to reduce the hyperspectral image data of samples, containing discrete particles or domains, to a single average spectrum per particle. The processing is automated and successful even when the particles are in contact. Focal Plane Array, Fourier transform infrared (FTIR) absorbance images of biological cells are used as an example dataset. The large number of spectra in the image (∼40 000) can be intelligently averaged to ∼100 mean spectra, approximately one per cell, greatly simplifying further analysis. As well as reducing the data, the morphological analysis provides useful information, such as the size of each cell, and allows every spectrum associated with each cell to be identified and analysed independently of the full dataset. Using these methods, combined with principal components analysis, consistent spectral differences are found between the spectra of the whole cells and a cell region approximately corresponding to the nucleus. These spectral differences compare well with previous IR measurements on whole CALU-1 cells and their isolated nuclei, but with a simpler sample preparation. The algorithm created to analyse the CALU-1 cells has been applied to a second cell line (NL20), which has a very different growth morphology, to demonstrate that this processing method is applicable to varied samples with little or no modification.