MSMahesh Kumar Swami

Mahesh Kumar Swami

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mahesh Kumar Swami has a total of 27 co-authors. Here are the top co-authors by number of shared publications:

  • Ashok Bhakar

    Accelerator Physics and Synchrotrons Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India

    2 shared publications
  • H.S. Patel

    Laser Biomedical Applications and Instrumentation Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India

    2 shared publications
  • P.K. Gupta

    Laser Biomedical Applications and Instrumentation Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India

    2 shared publications
  • Pooja Gupta

    Raja Ramanna Centre for Advanced Technology Indore India

    2 shared publications
  • Sanjay Kumar Rai

    Indus Synchrotrons Utilization Division, Raja Ramanna Centre for Advanced Technology 1 , Indore 452013

    2 shared publications
  • A. Uppal

    Laser Biomedical Applications and Instrumentation Division, Raja Ramanna Centre for Advanced Technology, Indore 452013, India

    1 shared publication

Latest Publications

  • BL-02: a versatile X-ray scattering and diffraction beamline for engineering applications at Indus-2 synchrotron source

    by Pooja Gupta, P. N. Rao, M. K. Swami, A. Bhakar, Sohan Lal, S. R. Garg, C. K. Garg, P. K. Gauttam, S. R. Kane, V. K. Raghuwanshi, et al.

    A hard X-ray engineering applications beamline (BL-02) was commissioned recently and started operation in March 2019 at the Indian synchrotron source, Indus-2. This bending-magnet-based beamline is capable of operating in various beam modes, viz. white, pink and monochromatic beam. The beamline utilizes the X-ray diffraction technique in energy-dispersive and angle-dispersive modes to carry out experiments mainly focused on engineering problems, viz. stress measurement, texture measurement and determination of elastic constants in a variety of bulk as well as thin-film samples. An open-cradle six-circle diffractometer with ∼12 kg load capacity allows accommodation of a wide variety of engineering samples and qualifies the beamline as a unique facility at Indus-2. The high-resolution mode of this beamline is suitably designed so as to carry out line profile analysis for characterization of micro- and nano-structures. In the present article the beamline is described starting from the beamline design, layout, optics involved, various operational modes and experimental stations. Experiments executed to validate the beamline design parameters and to demonstrate the capabilities of the beamline are also described. The future facilities to be incorporated to enhance the capabilities of the beamline are also discussed.


  • Line profile analysis of synchrotron X-ray diffraction data of iron powder with bimodal microstructural profile parameters

    by Ashok Bhakar, Pooja Gupta, P. N. Rao, M. K. Swami, Pragya Tiwari, Tapas Ganguli, S. K. Rai

    Room-temperature synchrotron X-ray diffraction and subsequent detailed line profile analysis of Fe powder were performed for microstructural characterization. The peak shapes of the diffraction pattern of Fe were found to be super-Lorentzian in nature and the peak widths were anisotropically broadened. These peak profile features of the diffraction pattern are related to the microstructural parameters of the material. In order to elucidate these features of the diffraction pattern, detailed line (peak) profile analyses were performed using the Rietveld method, modified Williamson–Hall plots and whole powder pattern modelling (WPPM), and related microstructural parameters were determined. Profile fitting using the Rietveld and WPPM methods with a single microstructural (unimodal) model shows systematic deviation from the experimentally observed diffraction pattern. On the basis of Rietveld analysis and microstructural modelling it is revealed that the microstructure of Fe consists of two components (bimodal profile). The microstructural parameters of crystallite/domain size distribution, dislocation density, nature of dislocations and phase fraction were evaluated for both components. The results obtained using different methods are compared, and it is shown that diffraction peak profile analysis is capable of modelling such inhomogeneous bimodal microstructures.


  • Structural variation in a synchrotron-induced contamination layer (a-C:H) deposited on a toroidal Au mirror surface

    by P. K. Yadav, R. K. Gupta, M. K. Swami, M. H Modi

    A carbon layer deposited on an optical component is the result of complex interactions between the optical surface, adsorbed hydrocarbons, photons and secondary electrons (photoelectrons generated on the surface of optical elements). In the present study a synchrotron-induced contamination layer on a 340 mm × 60 mm Au-coated toroidal mirror has been characterized. The contamination layer showed a strong variation in structural properties from the centre of the mirror to the edge region (along the long dimension of the mirror) due to the Gaussian distribution of the incident photon beam intensity/power on the mirror surface. Raman scattering measurements were carried out at 12 equidistant (25 mm) locations along the length of the mirror. The surface contamination layer that formed on the Au surface was observed to be hydrogenated amorphous carbon film in nature. The effects of the synchrotron beam intensity/power distribution on the structural properties of the contamination layer are discussed. The I(D)/I(G) ratio, cluster size and disordering were found to increase whereas the sp 2:sp 3 ratio, G peak position and H content decreased with photon dose. The structural parameters of the contamination layer in the central region were estimated (thickness ≃ 400 Å, roughness ≃ 60 Å, density ≃ 72% of bulk graphitic carbon density) by soft X-ray reflectivity measurements. The amorphous nature of the layer in the central region was observed by grazing-incidence X-ray diffraction.


  • Controlled shaping of photonic nanojets using core shell microspheres

    by P. K. Kushwaha, H. S. Patel, M. K. Swami, P. K. Gupta

    Photonic nanojet (PNJ), the sub wavelength confinement of light by dielectric microspheres is finding applications in nanoscale imaging, spectroscopy and nano lithography. These applications require control over the length and lateral dimension of the nanojets. In the paper we present the results of numerical simulation to show that a core shell microspheres can be used to generate photonic nanojet with controllable length and confinement by varying the relative refractive index of the microspheres and the separation between the core and shell centers. We show that a length of up to 27λ can be achieved when the core microsphere has lower refractive index than the shell and lateral dimensions down to λ/3 with core microsphere having higher refractive index.


  • Size-dependent patterns in depolarization maps from turbid medium and tissue

    by Mahesh Kumar Swami, Harishankar Patel, Madhura R. Somyaji, Pankaj Kumar Kushwaha, Pradeep Kumar Gupta

    Mueller matrix measurements on turbid media can be used to quantify its polarization properties in terms of retardance, diattenuation, and depolarization. In particular, the depolarizing ability of such media, which is represented by the depolarization index, has been shown to be a useful diagnostic parameter. However, being a single valued metric, its dependence on a host of tissue optical parameters makes it difficult to interpret. In this paper, we show that a map of depolarization as a function of input polarization state parameters can be used to infer information about the size of scatterer and order of birefringent and depolarizing layers in turbid medium. The experiments carried out on different mice organ tissues indicate that the depolarization characteristics of tissue are closely represented by depolarization properties of intralipid. We also observed that these maps do not vary in the presence of absorption.