Miles Greiner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Miles Greiner has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Hadj-Nacer
Mechanical Engineering Department, University of Nevada, Reno, NV 89557, USA
5 shared publications - Ahti Suo-Anttila
Computational Engineering Analysis, Albuquerque, NM
2 shared publications Carlos Lopez
Sandia National Laboratories
2 shared publicationsDilesh Maharjan
Univ Nevada, Dept Mech Engn, Reno, NV 89557 USA
2 shared publicationsA Smith
Savannah River National LaboratoryAiken, SC, USA
1 shared publicationAhti Suo-Anttila
1 shared publication
Latest Publications
- Open Access
- 16 July 2021
- Published by ASME International
Temperature Prediction of a Used Nuclear Fuel Cask With Different Gas Backfills
After used nuclear fuel (UNF) assemblies are removed from the reactor, they are immediately stored in cooling pools to lower their radioactivity and heat generation rates. After a few years, they are transferred to dry storage casks for interim storage. During the transition from wet storage (pool) to dry storage (cask), different non-oxidizing gases, such as helium, nitrogen, or
- 16 July 2021
- Published by ASME International
Open AccessTemperature Prediction of a Used Nuclear Fuel Cask With Different Gas Backfills
After used nuclear fuel (UNF) assemblies are removed from the reactor, they are immediately stored in cooling pools to lower their radioactivity and heat generation rates. After a few years, they are transferred to dry storage casks for interim storage. During the transition from wet storage (pool) to dry storage (cask), different non-oxidizing gases, such as helium, nitrogen, or
- 1 September 2020
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 158
Implementation and experimental validation of a computational model to predict temperatures and heat transfer of a square array of heated rods enclosed in a pressure vessel filled with rarefied dry helium
- 1 September 2020
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 158
Implementation and experimental validation of a computational model to predict temperatures and heat transfer of a square array of heated rods enclosed in a pressure vessel filled with rarefied dry helium
- Open Access
- 6 September 2017
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 10 (2)
Validated Simulations of Heat Transfer From a Vertical Heated-Rod Array to a Helium-Filled Isothermal Enclosure
Measurements of heat transfer from an array of vertical heater rods to the walls of a square, helium-filled enclosure are performed for a range of enclosure temperatures, helium pressures, and rod heat generation rates. This configuration is relevant to a used nuclear fuel assembly within a dry storage canister. The measurements are used to assess the accuracy of computational fluid dynamics (CFD)/radiation simulations in the same configuration. The simulations employ the measured enclosure temperatures as boundary conditions and predict the temperature difference between the rods and enclosure. These temperature differences are as large as 72 °C for some experiments. The measured temperature of rods near the periphery of the array is sensitive to small, uncontrolled variations in their location. As a result, those temperatures are not as useful for validating the simulations as measurements from rods near the array center. The simulated rod temperatures exhibit random differences from the measurements that are as large as 5.7 °C, but the systematic (average) error is 1 °C or less. The random difference between the simulated and measured maximum array temperature is 2.1 °C, which is less than 3% of the maximum rod-to-wall temperature difference.
- 6 September 2017
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 10 (2)
Open AccessValidated Simulations of Heat Transfer From a Vertical Heated-Rod Array to a Helium-Filled Isothermal Enclosure
Measurements of heat transfer from an array of vertical heater rods to the walls of a square, helium-filled enclosure are performed for a range of enclosure temperatures, helium pressures, and rod heat generation rates. This configuration is relevant to a used nuclear fuel assembly within a dry storage canister. The measurements are used to assess the accuracy of computational fluid dynamics (CFD)/radiation simulations in the same configuration. The simulations employ the measured enclosure temperatures as boundary conditions and predict the temperature difference between the rods and enclosure. These temperature differences are as large as 72 °C for some experiments. The measured temperature of rods near the periphery of the array is sensitive to small, uncontrolled variations in their location. As a result, those temperatures are not as useful for validating the simulations as measurements from rods near the array center. The simulated rod temperatures exhibit random differences from the measurements that are as large as 5.7 °C, but the systematic (average) error is 1 °C or less. The random difference between the simulated and measured maximum array temperature is 2.1 °C, which is less than 3% of the maximum rod-to-wall temperature difference.
- 10 January 2017
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (4) , 042002
Continuum and Kinetic Simulations of Heat Transfer Trough Rarefied Gas in Annular and Planar Geometries in the Slip Regime
Steady-state heat transfer through a rarefied gas confined between parallel plates or coaxial cylinders, whose surfaces are maintained at different temperatures, is investigated using the nonlinear Shakhov (S) model kinetic equation and Direct Simulation Monte Carlo (DSMC) technique in the slip regime. The profiles of heat flux and temperature are reported for different values of gas rarefaction parameter δ, ratios of hotter to cooler surface temperatures T, and inner to outer radii ratio R. The results of S-model kinetic equation and DSMC technique are compared to the numerical and analytical solutions of the Fourier equation subjected to the Lin and Willis temperature-jump boundary condition. The analytical expressions are derived for temperature and heat flux for both geometries with hotter and colder surfaces having different values of the thermal accommodation coefficient. The results of the comparison between the kinetic and continuum approaches showed that the Lin and Willis temperature-jump model accurately predicts heat flux and temperature profiles for small temperature ratio T=1.1 and large radius ratios R≥0.5; however, for large temperature ratio, a pronounced disagreement is observed.
- 10 January 2017
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (4) , 042002
Continuum and Kinetic Simulations of Heat Transfer Trough Rarefied Gas in Annular and Planar Geometries in the Slip Regime
Steady-state heat transfer through a rarefied gas confined between parallel plates or coaxial cylinders, whose surfaces are maintained at different temperatures, is investigated using the nonlinear Shakhov (S) model kinetic equation and Direct Simulation Monte Carlo (DSMC) technique in the slip regime. The profiles of heat flux and temperature are reported for different values of gas rarefaction parameter δ, ratios of hotter to cooler surface temperatures T, and inner to outer radii ratio R. The results of S-model kinetic equation and DSMC technique are compared to the numerical and analytical solutions of the Fourier equation subjected to the Lin and Willis temperature-jump boundary condition. The analytical expressions are derived for temperature and heat flux for both geometries with hotter and colder surfaces having different values of the thermal accommodation coefficient. The results of the comparison between the kinetic and continuum approaches showed that the Lin and Willis temperature-jump model accurately predicts heat flux and temperature profiles for small temperature ratio T=1.1 and large radius ratios R≥0.5; however, for large temperature ratio, a pronounced disagreement is observed.
- 12 February 2014
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 136 (2) , 021208
Development, Use, and Accuracy of a Homogenized Fuel Region Model for Thermal Analysis of a Truck Package Under Normal and Fire Accident Conditions
In the current work, a geometrically-accurate two-dimensional model is developed of an isolated fuel assembly within isothermal compartment walls. Finite difference thermal simulations are performed to determine the cladding temperature for a range of compartment wall temperatures and assembly heat generation rates. The results for zero-heat-generation-rate are used to determine a temperature-dependent effective thermal conductivity of the fuel region. The effective volumetric specific heat of the region is determined from a lumped capacity model. These effective properties are then applied to a two-dimensional model of a legal weight truck cask with homogenized (smeared) fuel regions. Steady-state normal conditions of transport simulations are performed for a range of fuel heat generation rates. The generation rate that brings the zircaloy cladding to its radial-hydride formation temperature, predicted by the homogenized model, is greater than that determined by simulations that employ an accurate-geometry fuel region model. Transient regulator fire accident simulations are then performed for a range of fire durations. The critical fire duration is defined as the minimum that brings the fuel cladding to its burst-rupture temperature. That duration is found to decrease as the fuel heat generation rate increases. The critical durations predicted by the homogenized fuel-region model are shorter than those predicted by the accurate-geometry model.
- 12 February 2014
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 136 (2) , 021208
Development, Use, and Accuracy of a Homogenized Fuel Region Model for Thermal Analysis of a Truck Package Under Normal and Fire Accident Conditions
In the current work, a geometrically-accurate two-dimensional model is developed of an isolated fuel assembly within isothermal compartment walls. Finite difference thermal simulations are performed to determine the cladding temperature for a range of compartment wall temperatures and assembly heat generation rates. The results for zero-heat-generation-rate are used to determine a temperature-dependent effective thermal conductivity of the fuel region. The effective volumetric specific heat of the region is determined from a lumped capacity model. These effective properties are then applied to a two-dimensional model of a legal weight truck cask with homogenized (smeared) fuel regions. Steady-state normal conditions of transport simulations are performed for a range of fuel heat generation rates. The generation rate that brings the zircaloy cladding to its radial-hydride formation temperature, predicted by the homogenized model, is greater than that determined by simulations that employ an accurate-geometry fuel region model. Transient regulator fire accident simulations are then performed for a range of fire durations. The critical fire duration is defined as the minimum that brings the fuel cladding to its burst-rupture temperature. That duration is found to decrease as the fuel heat generation rate increases. The critical durations predicted by the homogenized fuel-region model are shorter than those predicted by the accurate-geometry model.
- 15 July 2013
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 23 (4) , 300-319
Thermal measurements of a rail-cask-size pipe-calorimeter in jet fuel fires
Three large-scale fire tests were conducted in which a 2.4-m-(8-ft)-dia., 4.6-m-(15-ft)-long, 25-mm-(1-inch)-wall-thickness mild-steel pipe calorimeter was centered 1 m above a 7.9-m-dia. basin containing 7.57 m3 (2000 gal) of jet fuel. The wind conditions, calorimeter wall temperatures, and temperatures of foil radiant heat flux gages near the calorimeter were measured at several locations as functions of time during and after the fires. Video and still photography from several directions were used to monitor the calorimeter’s engulfment in flames. The objective of these tests was to determine how the fuel consumption rate, calorimeter coverage in flames and the calorimeter temperatures varied with wind conditions. These data can be used to benchmark computational and engineering models of heat transfer from large pool fires to thermally-massive objects. Those types of models are used to predict the response of rail-car-sized used-nuclear-fuel transport packages in severe accidents. The first two tests had average wind speeds of about 1 m/s and lasted for roughly 40 min. The third had 3-m/s winds and consumed the fuel in only 25 min. When winds blew toward a side or end of the calorimeter, the flames became thin and the radiant heat flux gage temperatures measured near those regions decreased. In the lower wind-speed tests, the calorimeter was more completely engulfed in flames and its temperatures were more uniform and reached higher average values compared to the high wind-speed test.
- 15 July 2013
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 23 (4) , 300-319
Thermal measurements of a rail-cask-size pipe-calorimeter in jet fuel fires
Three large-scale fire tests were conducted in which a 2.4-m-(8-ft)-dia., 4.6-m-(15-ft)-long, 25-mm-(1-inch)-wall-thickness mild-steel pipe calorimeter was centered 1 m above a 7.9-m-dia. basin containing 7.57 m3 (2000 gal) of jet fuel. The wind conditions, calorimeter wall temperatures, and temperatures of foil radiant heat flux gages near the calorimeter were measured at several locations as functions of time during and after the fires. Video and still photography from several directions were used to monitor the calorimeter’s engulfment in flames. The objective of these tests was to determine how the fuel consumption rate, calorimeter coverage in flames and the calorimeter temperatures varied with wind conditions. These data can be used to benchmark computational and engineering models of heat transfer from large pool fires to thermally-massive objects. Those types of models are used to predict the response of rail-car-sized used-nuclear-fuel transport packages in severe accidents. The first two tests had average wind speeds of about 1 m/s and lasted for roughly 40 min. The third had 3-m/s winds and consumed the fuel in only 25 min. When winds blew toward a side or end of the calorimeter, the flames became thin and the radiant heat flux gage temperatures measured near those regions decreased. In the lower wind-speed tests, the calorimeter was more completely engulfed in flames and its temperatures were more uniform and reached higher average values compared to the high wind-speed test.
- 1 December 2011
- Published by Taylor & Francis in Packaging, Transport, Storage & Security of Radioactive Material
- Vol. 22 (4) , 206-216
Modelling of polyurethane foam thermal degradation within annular region subject to fire conditions
Nuclear materials are placed in shielded, stainless steel packaging for storage or transport. These drum type packages often employ a layer of foam, honeycomb, wood or cement that is sandwiched between thin metal shells to provide impact and thermal protection during hypothetical accidents, as those prescribed in the Code of Federal Regulations (10 CFR 71·73). The present work discusses the modelling of the thermal degradation of polyurethane (PU) foam within an annular region during an 800°C fire. Measurements and analysis by Hobbs and Lemmon [M. L. Hobbs and G. H. Lemmon: ‘Polyurethane foam response to fire in practical geometries’, Polym. Degrad. Stab., 2004, 84, 183–197.] indicate that at elevated temperatures, PU foam exhibits a two-stage, endothermic degradation. The first stage produces a degraded solid and a combustible gas; the second stage reaction consumes the degraded solid and produces another combustible gas. As a result, during a prolonged fire, a gas filled void develops beside the outer metal shell and grows inward toward the inner shell and the containment vessel. As a result of the radial symmetry in the drum geometry, a one-dimensional finite difference model is constructed for the annular foam region. Heat flux is applied to the inner surface to model the decay heat of the containment vessel contents. Thermal radiation and convection boundary conditions with a specified environmental temperature are applied to the outer surface. The material and reaction rate properties determined by Hobbs and Lemmon are applied to the foam. The annular region temperature and composition are determined as functions of radius and time after the environmental conditions are changed from room temperature to those of an 800°C fire. The effects of surface to surface radiation between the package’s outer skin and the undegraded foam and the reaction rate reduction due to material damage during the reaction are evaluated for fires lasting 20 h. The peak package liner temperature caused by a 30 min fire is predicted to be 129°C, well below the short term limit for containment vessel seal (377°C).
- 1 December 2011
- Published by Taylor & Francis in Packaging, Transport, Storage & Security of Radioactive Material
- Vol. 22 (4) , 206-216
Modelling of polyurethane foam thermal degradation within annular region subject to fire conditions
Nuclear materials are placed in shielded, stainless steel packaging for storage or transport. These drum type packages often employ a layer of foam, honeycomb, wood or cement that is sandwiched between thin metal shells to provide impact and thermal protection during hypothetical accidents, as those prescribed in the Code of Federal Regulations (10 CFR 71·73). The present work discusses the modelling of the thermal degradation of polyurethane (PU) foam within an annular region during an 800°C fire. Measurements and analysis by Hobbs and Lemmon [M. L. Hobbs and G. H. Lemmon: ‘Polyurethane foam response to fire in practical geometries’, Polym. Degrad. Stab., 2004, 84, 183–197.] indicate that at elevated temperatures, PU foam exhibits a two-stage, endothermic degradation. The first stage produces a degraded solid and a combustible gas; the second stage reaction consumes the degraded solid and produces another combustible gas. As a result, during a prolonged fire, a gas filled void develops beside the outer metal shell and grows inward toward the inner shell and the containment vessel. As a result of the radial symmetry in the drum geometry, a one-dimensional finite difference model is constructed for the annular foam region. Heat flux is applied to the inner surface to model the decay heat of the containment vessel contents. Thermal radiation and convection boundary conditions with a specified environmental temperature are applied to the outer surface. The material and reaction rate properties determined by Hobbs and Lemmon are applied to the foam. The annular region temperature and composition are determined as functions of radius and time after the environmental conditions are changed from room temperature to those of an 800°C fire. The effects of surface to surface radiation between the package’s outer skin and the undegraded foam and the reaction rate reduction due to material damage during the reaction are evaluated for fires lasting 20 h. The peak package liner temperature caused by a 30 min fire is predicted to be 129°C, well below the short term limit for containment vessel seal (377°C).
- 23 November 2011
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 22 (1) , 45-70
Benchmarking of Container Analysis Fire Environment simulation using the memorial tunnel fire ventilation tests
Previously, the US Nuclear Regulatory Commission performed simulations using fire dynamics simulator (FDS) software to predict the response of spent nuclear fuel transport packages in severe naturally ventilated tunnel fires. The long-range objective of the authors’ current project is to predict the response of such a package to those tunnel fires using different computational methods. The first stage of the project, which is the subject of this article, is to determine the accuracy of Container Analysis Fire Environment (CAFE) computer simulations in predicting gas speed and temperature measurements made in forced-ventilated and naturally ventilated fires from the Memorial tunnel test series performed for the Massachusetts Highway Department in the 1990s. The CAFE simulations accurately predict the average heat release rate in both types of tests. Gas speeds and temperatures are obtained from the simulations at the same locations as for the measurements. For the forced-ventilated test, CAFE predicts those quantities more accurately upstream of the fire than downstream. In addition, the predictions are less accurate for the naturally ventilated test than they are for the forced-ventilated experiment. However, the accuracy of the CAFE prediction in the naturally ventilated test is on par with that from FDS.
- 23 November 2011
- Published by SAGE Publications in Journal of Fire Protection Engineering
- Vol. 22 (1) , 45-70
Benchmarking of Container Analysis Fire Environment simulation using the memorial tunnel fire ventilation tests
Previously, the US Nuclear Regulatory Commission performed simulations using fire dynamics simulator (FDS) software to predict the response of spent nuclear fuel transport packages in severe naturally ventilated tunnel fires. The long-range objective of the authors’ current project is to predict the response of such a package to those tunnel fires using different computational methods. The first stage of the project, which is the subject of this article, is to determine the accuracy of Container Analysis Fire Environment (CAFE) computer simulations in predicting gas speed and temperature measurements made in forced-ventilated and naturally ventilated fires from the Memorial tunnel test series performed for the Massachusetts Highway Department in the 1990s. The CAFE simulations accurately predict the average heat release rate in both types of tests. Gas speeds and temperatures are obtained from the simulations at the same locations as for the measurements. For the forced-ventilated test, CAFE predicts those quantities more accurately upstream of the fire than downstream. In addition, the predictions are less accurate for the naturally ventilated test than they are for the forced-ventilated experiment. However, the accuracy of the CAFE prediction in the naturally ventilated test is on par with that from FDS.
- Open Access
- 1 January 2010
- Published by ASME International
- p. 561-571
Validation of Container Analysis Fire Environment (CAFE) Code for Memorial Tunnel Fire Ventilation Test Program
The Container Analysis Fire Environment (CAFE) computer code was developed at Sandia National Laboratories to predict the response of spent nuclear fuel (SNF) transport packages in large fires. CAFE’s fire model has been benchmarked using measurements from large, unconfined outdoor fires. In the current work CAFE simulations are benchmarked using data acquired in two fires from the Memorial Tunnel test series. The Memorial Tunnel, a decommissioned highway tunnel in West Virginia, is 850 m (2,800 ft) long, 4.38 m (14.3 ft) wide, and has a 3.2% slope. In both fires, the time-dependent air temperature and speed were measured at several locations throughout the tunnel during 50 MW fires. The first test used forced ventilation and the upper portal of the tunnel was sealed. Shortly after the fire started, air was forced into the tunnel at a location between the sealed portal and the fire, forcing the air flow toward the lower portal. The second test used natural ventilation, in that both portals were open and there was no forced flow. However, wind outside the tunnel appeared to cause a net flow inside, even before the fire started. While the Memorial Tunnel Fire test conditions and results were well documents, some details were not available to the current authors. This necessitated the used of some assumptions. CAFE simulations accurately reproduced many of the characteristics of the temporal and spatial variation of the measured air speed and temperature. The maximum simulated temperatures for the forced and naturally ventilated tests were, respectively, 26°F (14°C) and 201°F (94°C) below the corresponding measured values. This work will be used to assess the accuracy of CAFE in predicting the likely response of SNF packages in historic transportation tunnel fires.
- 1 January 2010
- Published by ASME International
- p. 561-571
Open AccessValidation of Container Analysis Fire Environment (CAFE) Code for Memorial Tunnel Fire Ventilation Test Program
The Container Analysis Fire Environment (CAFE) computer code was developed at Sandia National Laboratories to predict the response of spent nuclear fuel (SNF) transport packages in large fires. CAFE’s fire model has been benchmarked using measurements from large, unconfined outdoor fires. In the current work CAFE simulations are benchmarked using data acquired in two fires from the Memorial Tunnel test series. The Memorial Tunnel, a decommissioned highway tunnel in West Virginia, is 850 m (2,800 ft) long, 4.38 m (14.3 ft) wide, and has a 3.2% slope. In both fires, the time-dependent air temperature and speed were measured at several locations throughout the tunnel during 50 MW fires. The first test used forced ventilation and the upper portal of the tunnel was sealed. Shortly after the fire started, air was forced into the tunnel at a location between the sealed portal and the fire, forcing the air flow toward the lower portal. The second test used natural ventilation, in that both portals were open and there was no forced flow. However, wind outside the tunnel appeared to cause a net flow inside, even before the fire started. While the Memorial Tunnel Fire test conditions and results were well documents, some details were not available to the current authors. This necessitated the used of some assumptions. CAFE simulations accurately reproduced many of the characteristics of the temporal and spatial variation of the measured air speed and temperature. The maximum simulated temperatures for the forced and naturally ventilated tests were, respectively, 26°F (14°C) and 201°F (94°C) below the corresponding measured values. This work will be used to assess the accuracy of CAFE in predicting the likely response of SNF packages in historic transportation tunnel fires.