ASAhti Suo-Anttila

Ahti Suo-Anttila

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ahti Suo-Anttila has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of Container Analysis Fire Environment (CAFE) Code for Memorial Tunnel Fire Ventilation Test Program

    by N. R. Chalasani, Miles Greiner, Ahti Suo-Anttila

    The Container Analysis Fire Environment (CAFE) computer code was developed at Sandia National Laboratories to predict the response of spent nuclear fuel (SNF) transport packages in large fires. CAFE’s fire model has been benchmarked using measurements from large, unconfined outdoor fires. In the current work CAFE simulations are benchmarked using data acquired in two fires from the Memorial Tunnel test series. The Memorial Tunnel, a decommissioned highway tunnel in West Virginia, is 850 m (2,800 ft) long, 4.38 m (14.3 ft) wide, and has a 3.2% slope. In both fires, the time-dependent air temperature and speed were measured at several locations throughout the tunnel during 50 MW fires. The first test used forced ventilation and the upper portal of the tunnel was sealed. Shortly after the fire started, air was forced into the tunnel at a location between the sealed portal and the fire, forcing the air flow toward the lower portal. The second test used natural ventilation, in that both portals were open and there was no forced flow. However, wind outside the tunnel appeared to cause a net flow inside, even before the fire started. While the Memorial Tunnel Fire test conditions and results were well documents, some details were not available to the current authors. This necessitated the used of some assumptions. CAFE simulations accurately reproduced many of the characteristics of the temporal and spatial variation of the measured air speed and temperature. The maximum simulated temperatures for the forced and naturally ventilated tests were, respectively, 26°F (14°C) and 201°F (94°C) below the corresponding measured values. This work will be used to assess the accuracy of CAFE in predicting the likely response of SNF packages in historic transportation tunnel fires.

  • Benchmark of a Fast-Running Computational Tool for Analysis of Massive Radioactive Material Packages in Fire Environments

    by Narendra Are, Miles Greiner, Ahti Suo-Anttila

    Federal regulations (10CFR71) require radioactive material transport packages to safely withstand a 30min fully engulfing fire. The three-dimensional Container Analysis Fire Environment (CAFE-3D ) computer code was developed at Sandia National Laboratories to simulate the response of massive packages to large fires for design and risk studies. These studies require rapid and accurate estimates of the package temperature distribution for a variety of package designs and fire environments. To meet these needs CAFE-3D links a finite element model that calculates the package response to the Isis-3D CFD fire model. ISIS-3D combines computational fluid dynamics with reaction chemistry and thermal radiation models to rapidly estimate the heat transfer from a fire. In the current work, parameters used in the fire model were determined. Simulations were then performed of a test that modeled the conditions of a truck-sized nuclear waste package in a regulatory fire under light wind conditions. CAFE-3D underestimated the ability of the wind to tilt the fire and deliver oxygen to the region above the fuel pool. However, it accurately and rapidly estimated the total heat transfer to the test object. CAFE-3D will become a more useful tool for estimating the response of transport packages to large fires once it has been benchmarked against a larger range of fire conditions.