MZMansour Zenouzi

Mansour Zenouzi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mansour Zenouzi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Integration of Combined Heat and Power With Renewables and Energy Storage for Reducing Carbon Emission in Transition Pathway Toward Carbon Neutrality

    by Mansour Zenouzi, Yasin Naman, Gregory Kowalski

    Strong synergies exist between cogeneration and renewables for reducing emission of harmful gases in the transition period toward carbon neutrality. Integration of combined heat and power (CHP) with renewables and energy storage along with electrification of buildings is a pathway to create resilient and efficient solutions towards decarbonization. Optimizing the size of a CHP system to satisfy both electrical and thermal loads of a given facility while minimizing fuel consumption is a challenging problem. The thermal load consists of heating, cooling, or hot water production. Integration of renewable energy sources and energy storage presents additional design challenges. An interactive software was developed by the authors to quickly estimate the performance of different configurations of CHP and renewable energy sources and it was tested for an office complex of four commercial buildings found in National Renewable Energy Laboratory's dataset End-Use Load Profiles for the U.S. Building Stock. The software is intended to size CHP devices and calculate the Energy Utilization Factor (EUF), CO2 emissions, and the rate of Entropy Production. A heat pump module and solar photovoltaic with electrical power storage were introduced for this study. The objective of this paper is to compare different configurations of renewable or low-emission technologies and design an appropriate solution for a test data set for a Typical Metrological Year (TMY). The software requires energy inputs separated by cooling load, heating load, and electric demand as a time series and is used to optimize the plant size to match all the loads to the corresponding systems.


  • Open Access

    Electrostatic Charge on Smartphone Surfaces

    by John Voccio, Valeria Vivas Merino, Mansour Zenouzi, Andrew Seredinski, William Burgess, Nicholas Daly

    Mobile phones, tablets, and capacitive touchscreens, in general, are ubiquitous in modern society. In this study, the electrostatic charge present near the capacitive touchscreen surfaces was investigated. Results from a Faraday pail experiment indicate that smartphones present an electrostatic charge due to charging and that the magnitude of this charge can vary due to adding additional materials, such as those used as common screen protectors, or by triboelectric events, such as rubbing against another material, as is the case when removing a phone from a pants pocket, for example. Furthermore, this charge increases with lower ambient relative humidity. Understanding these electrostatic charge behaviors may prove useful in minimizing the possibility of either attracting or dispersing unwanted electrically charged particles, such as dust, viruses, or contaminated aerosols, especially in indoor environments with low relative humidity (RH < 40%).


  • Exergy Analysis-Potential of Salinity Gradient Energy Source

    by Arash Emdadi, Mansour Zenouzi, Amir Lak, Behzad Panahirad, Yunus Emami, Farshad Lak, Gregory J. Kowalski

    Mixing of fresh (river) water and salty water (seawater or saline brine) in a controlled environment produces an electrical energy known as salinity gradient energy (SGE). Two main conversion technologies of SGE are membrane-based processes: pressure retarded osmosis (PRO) and reverse electrodialysis (RED). Exergy calculations for a representative river-lake system are investigated using available data in the literature between 2000 and 2008 as a case study. An exergy analysis of an SGE system of sea-river is applied to calculate the maximum potential power for electricity generation. Seawater is taken as reference environment (global dead state) for calculating the exergy of fresh water since the sea is the final reservoir. Aqueous sodium chloride solution model is used to calculate the thermodynamic properties of seawater. This model does not consider seawater as an ideal solution and provides accurate thermodynamics properties of sodium chloride solution. The chemical exergy analysis considers sodium chloride (NaCl) as main salt in the water of this highly saline Lake with concentration of more than 200 g/L. The potential power of this system is between 150 and 329 MW depending on discharge of river and salinity gradient between the Lake and the River based on the exergy results. This result indicates a high potential for constructing power plant for SGE conversion. Semipermeable membranes with lifetime greater than 10 years and power density higher than 5 W/m2 would lead to faster development of this conversion technology.


  • Significance of Transient Exergy Terms in a New Tray Design Solar Desalination Device

    by Gregory J. Kowalski, Masoud Modaresifar, Mansour Zenouzi

    An investigation of the transient exergy property term, exergy storage, for a new desalination tray design was performed. It was illustrated that exergy destruction rates provide a means of comparing alternative energy solutions and a measure of their sustainability. To satisfy these objectives one needs accurate calculation of exergy destruction rates. It was confirmed that neglecting the exergy storage term is not a valid approximation for the hourly and daily averaged values of the second law analysis. For a solar desalination system neglecting the exergy storage terms introduced a maximum difference in the exergy destruction rate of 7.4% and a difference of 7.3% in the daily average. In the solar desalination process with energy recovery the second law performance is greater than that for the reverse osmosis (RO) process, the chief competitor, when the exergy storage terms are correctly included in the analysis. The results demonstrate that for variable energy sources such as renewable energy systems, the second law analysis provides a measure of the sustainability of competing system and that the exergy storage terms should be included in the analysis.


  • Predicted Performance of an Integrated Solar Thermal and Photovoltaic System With Hybrid Turbine-Fuel Cell Cogeneration System

    by Gregory J. Kowalski, Mansour Zenouzi

    A general approach, the HLRP technique, for determining the performance of a hybrid turbine-fuel cell cogeneration system with a renewable energy sources is presented for a domestic residence. The hybrid-cogeneration system provides the electric power as well as satisfying heating loads. In this paper a system level analysis that includes practical values of heat exchangers, pumps, and storage equipment is presented. The use of the ratio of the thermal load to required power parameter (HLRP), which has been used by the authors to scale energy systems, allows the performance to be quickly determined and preliminary carbon dioxide production rates and cost effects to be estimated. The present paper includes solar energy systems as renewable energy to illustrate the development of this technique and its integration with the hybrid fuel cell cogeneration system. Practical values of solar collector efficiency and storage tank and battery storage efficiency are included. The analysis focused on matching the transient characteristics of the power and thermal loads with those of the renewable energy system. The results demonstrate that for a typical winter day in the location studied there are not large variations in the energy utilization factors for the four different systems investigated. There is a 23% reduction in the carbon dioxide produced using the solar thermal or combined system as compared to the no renewable energy or photovoltaic systems. The information provided by the performance graphs is used to estimate costs for each system and to easily determine which system is the most efficient for satisfying energy requirements and reducing green house gas emissions. The results provide site planners and physical plant operators with initial information that can be used to design new facilities or effectively integrate large plant expansion that include renewable energy systems in a manner that will minimize energy requirements and reduce pollution effects.

  • Renewable Energy and Hybrid Turbine-Fuel Cell Cogeneration System’s Predicted Performance

    by Gregory J. Kowalski, Mansour Zenouzi

    A normalized, general approach for determining the combined performance of a hybrid turbine-fuel cell cogeneration system with a renewable energy source, such as a solar thermal system is presented. The hybrid-cogeneration system provides required electric power as well as satisfying simultaneous heating loads. In this paper a system level analysis that includes practical values of heat exchangers, pumps, and storage equipment is presented. The use of the ratio of the thermal load to required power parameter (HLRP), which has been previously used by the authors to scale energy systems, allows the performance to be quickly determined and preliminary carbon dioxide production rates and cost effects to be estimated. The present paper will focus on a solar thermal system as renewable energy to illustrate the development of this technique and its integration with the hybrid fuel cell cogeneration system. Practical values of solar collector efficiency and storage tank efficiency are included. The analysis will focus on matching the transient characteristics of the power and thermal loads with those of the renewable energy system. Performance measures used to evaluate the investigated designs include the energy utilization factor and the carbon dioxide produced per unit power output. The information provided by the performance graphs can be used to estimate costs for each system and to easily determine which system is the most efficient for satisfying energy requirements and reducing green house gas emissions. The results provide site planners and physical plant operators with initial information that can be used to design new facilities or effectively integrate large plant expansion that include renewable energy systems in a manner that will minimize energy requirements and reduce pollution effects.

  • Selection of Distributed Power-Generating Systems Based on Electric, Heating, and Cooling Loads

    by Gregory J. Kowalski, Mansour Zenouzi

    A generalized thermodynamic model is developed to describe combined cooling, heating, and power generating systems. This model is based on reversible power generation and refrigeration devices with practical, irreversible heat exchanger processes. It provides information on a system’s performance and allows easy comparisons among different systems at different loading conditions. Using both the first and second laws as well as the carbon dioxide production rate allows one to make a first-order system assessment of its energy usage and environment impact. The consistency of the exergy destruction rate and the first law performance ensures that the thermodynamic system boundaries are correctly and completely defined. The importance of the total thermal load to the required power ratio (HLRP) as a scaling parameter is demonstrated. A number of trends for limited conditions can be delineated even though the reported results confirmed that generalized trends are not identifiable because of the systems’ complexities. The results demonstrate that the combined vapor compression∕absorption refrigeration has higher first law utilization factors and lower carbon dioxide production rate for systems with high refrigeration to total thermal load ratios for all HLRP values. Fuel cell systems outperform engine systems for large refrigeration load applications. An illustration of combining these results to an economic analysis is presented.