MDMing Deng

Ming Deng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ming Deng has a total of 42 co-authors. Here are the top co-authors by number of shared publications:

  • Danqi Feng

    Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing, China

    6 shared publications
  • Wei Sun

    State Key Laboratory of the Gas Disaster Detecting, Preventing and Emergency Controlling, Chongqing, China

    5 shared publications
  • Meng Li

    Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China

    4 shared publications
  • Sanfeng Gu

    Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China

    3 shared publications
  • Sanfeng Gu

    Key Laboratory of Optoelectronic Technology and Systems (Ministry of Education), Chongqing University, Chongqing, China

    3 shared publications
  • Xinhao Nan

    Key Laboratory of Optoelectronic Technology and Systems (Ministry of Education), Chongqing University, Chongqing, China

    3 shared publications

Latest Publications

  • Open Access

    An Innovative Semiparametric Density Model for the Statistical Characterization of Ground-Vehicle Radar Cross Sections

    by Zengcan Liu, Shuhao Wen, Houjun Sun, Ming Deng

    Accurately characterizing the statistical fluctuations of vehicle radar cross sections (RCSs) across polarization states and azimuthal sectors is essential for evaluating detection performance, conducting probabilistic simulations, and analyzing target features in millimeter-wave radar systems. Existing one-dimensional RCS statistical models, including Weibull, Chi-square, Lognormal, Rice, and Gaussian distributions, are often limited by their restricted functional expressiveness, making it difficult to simultaneously capture skewness, tail thickness, and azimuthal dependence under narrow angular-domain conditions. In addition, purely nonparametric approaches tend to produce spurious modes under finite-sample conditions and lack interpretable structural priors. To address these limitations, this paper proposes a Unimodal RCS Semiparametric Density Estimator (URCS-SDE) tailored for ground-vehicle targets. The proposed approach adopts kernel density estimation (KDE) as a data-driven baseline representation and incorporates physically plausible structural constraints through unimodal shape projection. Then a beta-type tail template is further introduced in the normalized amplitude domain to regulate boundary decay behavior. Finally, weighted least-squares calibration is performed on the histogram grid of the empirical probability density function (PDF), achieving a balanced trade-off between fitting accuracy and stability in both the peak and tail regions. Using multi-azimuth RCS measurements of two representative ground vehicles, the URCS-SDE is systematically compared with five classical parametric distributions and a representative regularized mixture density network (MDN) baseline. Performance is evaluated under both full-azimuth and directional-window conditions using the sum of squared errors (SSE), root mean squared error (RMSE), coefficient of determination (R-square) and held-out negative log-likelihood (NLL). The results show that the URCS-SDE consistently provides the most accurate and stable density estimates, especially in narrow angular windows. In addition, a threshold-based detection-support example derived from the fitted PDFs demonstrates that the advantage of the URCS-SDE transfers from density reconstruction to a directly engineering-relevant downstream quantity.

  • Highly Sensitive Multiparametric Sensors Based on Mach–Zehnder Interferometers via Twin-Core Yb-Doped Optical Fibers

    by Mengyao Zhang, Qiancheng Zhao, Jinyin Yan, Changyuan Yu, Gang-Ding Peng, Ming Deng, Tao Zhu

    An all-fiber Mach-Zehnder interferometer (MZI) sensor for measuring temperature (low and high), curvature, strain, refractive index, and taper curvature is proposed and experimentally demonstrated. This is the first time that the sensing properties of a twin-core fiber are combined with the fluorescence properties of ytterbium-doped fiber. The structure consists of a twin-core ytterbium-doped fiber with a central air hole sandwiched between two single-mode fibers. Based on the theoretical analysis, the sensing properties of the proposed all-fiber MZI-based sensor are analyzed. The experimental results show that the spectral interference of the proposed sensor has a favorable linear relationship to the curvature, temperature, and strain characteristics. Moreover, the curvature-intensity sensitivity of the twin-core YDF is greatly improved by the fiber tapering method. Furthermore, the emission characteristic of YDF also shows excellent sensitivity for the high-temperature sensing region. The study shows that our proposed MZI based on twin-core YDF offers great potential for practical multiparametric sensing.


  • Highly Sensitive Magnetic Field Measurement Based on Radio Frequency Assisted Polarization Interferometer and Harmonic Vernier Effect

    by Danqi Feng, Haiyang Wang, Wentao Zhong, Ming Deng

    We have proposed and experimentally demonstrated a novel approach for magnetic field measurement using a radio frequency-assisted polarization interferometer combined with the harmonic Vernier Effect. Based on the polarization dependence of the electro-optical modulator, the orthogonal light beams have different time delays, which makes radiofrequency-assisted polarization interference feasible to happen. When feeding the modulated signal into one interferometer, Vernier Effect can emerge. By adjusting the time delay of the interferometer, various harmonic orders of the Vernier Effect can be achieved, thereby enhancing the sensitivity. The sensing head is the magneto-optic crystal, where the Fraday effect occurs with the magnetic field. With the applied magnetic field, the valley of the Vernier envelope begin to split. We can obtain the magnetic field by measuring the split spacing. Experimental results indicate that the magnetic field sensitivity reaches 329 kHz/Oe. The proposed scheme boasts higher sensitivity and greater system simplicity, making it a valuable reference for certain magnetic field measurement applications.

  • Faraday Rotation Angle Measurement Based on Coupled Optoelectronic Oscillator with Temperature Compensation

    by Danqi Feng, Yuwei Liu, Haiyang Wang, Ming Deng

    We have proposed and experimentally demonstrated a high-precision and temperature-compensated Faraday rotation angle measurement based on Coupled Optoelectronic Oscillator (COEO). The COEO contains two positive feedback loops. The magnetic-optics crystal is positioned outside the laser loop and in the OEO loop, where the Faraday Effect occurs. The polarization of the light from the laser loop will be rotated. Combined with the polarizer, the intensity of the photocurrent, which is the driving signal of the MZM, fluctuates according to the Faraday rotation angle. The variation of the active mode-locked modulation signal will change the loss of the laser loop, as well as the oscillation optical mode and the laser wavelength. Serving as the optical source of the OEO loop, the wavelength shift will induce the oscillation frequency shift. The oscillation frequency has a linear relationship with the Faraday rotation angle. Benefitting from the matching of two loops, the system can mitigate temperature disturbances, making it suitable for dual-parameter sensing applications. The experimental results show that the sensitivities of the Faraday rotation angle and temperature are 375.73 Hz/deg and 1.6 kHz/°C. The max errors for rotation angle and temperature are 0.29 ° and 0.39 °C, respectively.


  • Large-Range and Highly Sensitive Displacement Measurement With an Optical Carrier-Based Microwave Interferometry

    by Zhonghao Li, Sanfeng Gu, Danqi Feng, Xinhao Nan, Ming Deng, Tao Zhu

    In this paper, we proposed a wide-range and highly sensitive displacement measurement system based on the optical carrier-based microwave interferometry (OCMI), in which two kinds of optical carriers are used. Theoretical analyses have been carried out to investigate the effect of the initial phase caused by the length difference between the sensing arm and the reference one on the measurement sensitivity. It suggests that the smaller the initial phase induced by the arm length difference, the higher the measurement sensitivity is. Experimental results show that the system utilizing lasers as optical carriers can greatly reduce the initial phase and the measurement sensitivity is more than twice that of the system using broadband light source acting as carrier in a 3 GHz bandwidth. The measurement accuracy is 4 μm and the measurement range is more than 40 mm, as well as the stability is within ±2 μm. As a result, the proposed displacement measurement system possesses the merits of wide measurement range, high sensitivity and high accuracy, which offers great potentials in the fields of precise displacement measurement.


  • Open Access

    A Polarimetric Fiber Ring Laser Incorporating a Coupled Optoelectronic Oscillator and Its Application to Magnetic Field Sensing

    by Danqi Feng, Yangxu Tang, Run Lei, Ziqing Feng, Ming Deng

    A novel configuration for a polarimetric fiber ring laser incorporating a coupled optoelectronic oscillator (COEO) is proposed and experimentally demonstrated, and its application to magnetic field sensing is studied. The COEO-based polarimetric fiber ring laser has two mutually coupled loops: the fiber ring laser loop and the OEO loop. In the fiber ring laser loop, longitudinal modes break up into orthogonal polarization modes because of birefringence. The frequency of the polarization mode beat (PMB) signals is determined by the cavity birefringence. In the OEO loop, a microwave signal with its frequency equal to the PMB signal is generated. By feeding the oscillation mode to modulate the optical loop, mode-locking can be achieved, rendering the mode spacing of the laser equal to the frequency of the oscillating OEO mode. We can estimate the birefringence variation by measuring the oscillating frequency of the COEO. To validate the proposed sensing system, a circular birefringence change is introduced in a magneto-optic crystal via the Faraday rotation effect. Then, the magnetic field sensing is implemented. Such configuration can achieve single longitudinal oscillation and realize high-speed and high-precision measurements.


  • Open Access

    Highly Precise Magnetic Field Measurement Based RF-Assisted Sagnac Interferometer With Tapered Fiber

    by Sanfeng Gu, Danqi Feng, Yangxu Tang, Zhonghao Li, Xinhao Nan, Tianqi Wang, Ming Deng

    A radio frequency (RF)-assisted Sagnac interferometer based on a dual-loop optoelectronic oscillator (OEO) is experimentally demonstrated for high-precision magnetic field measurement, in which the tapered fiber covered with the magnetic fluid (MF) as the magnetic field sensing head is embedded in the Sagnac interferometer. The evanescent field of the tapered fiber can interact with the MF under the external magnetic field to cause the birefringence variation of the fundamental mode, leading to the change in the free spectral range (FSR) of the interferometer, which can be mapped to the oscillation frequency shift of the OEO in the microwave domain. By the above converting, the magnetic field measurement with high interrogation speed and resolution can be realized. In addition, the designed device shows a certain measurement directionality of the magnetic field due to two orthogonally polarized fundamental modes asymmetric to the magnetic field, obtaining a good conformity with the constructed theoretical models. The experimental results show the maximum magnetic field sensitivities of 159.4 Hz/mT in the range of 8.48-27.83 mT, and 350.8 Hz/mT in the range of 0-5.14 mT, corresponding to the light wave vector parallel and perpendicular to the magnetic field, respectively.


  • Open Access

    High-Precision Magnetic Field Sensor Based on Fiber Bragg Grating and Dual-Loop Optoelectronic Oscillator

    by Wei Sun, Xiangyu Liu, Ming Deng

    A novel fiber-optic magnetic field sensor with high interrogation speed and resolution by using an etched fiber Bragg grating (FBG) in conjunction with a dual-loop optoelectronic oscillator (OEO) is proposed and experimentally demonstrated. A commercial FBG is firstly dipped into mixed hydrofluoric acid solution to remove the cladding layer and then is embedded with the magnetic fluid (MF) as a sensing element. The central wavelength reflected from the FBG is related to the overall time delay of the dual-loop OEO, which determines the oscillating frequency of the OEO. Therefore, the magnetic field can be estimated by measuring the oscillating frequency shift of OEO. The experimental results show that the oscillating frequency linearly increases with the increment of the magnetic field, achieving the sensitivity of 16.3 Hz/Oe with a R -square of 0.991 in the range of 5 mT–10 mT. In addition, the maximum error is within ±0.05 mT in the range of 7 mT–8 mT, which offers potentials in many fields where the high-precision magnetic field measurement is required.