Sanfeng Gu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sanfeng Gu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Danqi Feng
Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing, China
3 shared publications - Ming Deng
Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China
3 shared publications Hairui Fang
Institute of Advanced Sensor Technology, Northeast Electric Power University, Jilin 132012, China
2 shared publicationsShengxi Jiao
Institute of Advanced Sensor Technology, Northeast Electric Power University, Jilin 132012, China
2 shared publications- Tao Zhu
Chongqing University
2 shared publications Xinhao Nan
Key Laboratory of Optoelectronic Technology and Systems (Ministry of Education), Chongqing University, Chongqing, China
2 shared publications
Latest Publications
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6792-6798
Large-Range and Highly Sensitive Displacement Measurement With an Optical Carrier-Based Microwave Interferometry
In this paper, we proposed a wide-range and highly sensitive displacement measurement system based on the optical carrier-based microwave interferometry (OCMI), in which two kinds of optical carriers are used. Theoretical analyses have been carried out to investigate the effect of the initial phase caused by the length difference between the sensing arm and the reference one on the measurement sensitivity. It suggests that the smaller the initial phase induced by the arm length difference, the higher the measurement sensitivity is. Experimental results show that the system utilizing lasers as optical carriers can greatly reduce the initial phase and the measurement sensitivity is more than twice that of the system using broadband light source acting as carrier in a 3 GHz bandwidth. The measurement accuracy is 4 μm and the measurement range is more than 40 mm, as well as the stability is within ±2 μm. As a result, the proposed displacement measurement system possesses the merits of wide measurement range, high sensitivity and high accuracy, which offers great potentials in the fields of precise displacement measurement.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6792-6798
Large-Range and Highly Sensitive Displacement Measurement With an Optical Carrier-Based Microwave Interferometry
In this paper, we proposed a wide-range and highly sensitive displacement measurement system based on the optical carrier-based microwave interferometry (OCMI), in which two kinds of optical carriers are used. Theoretical analyses have been carried out to investigate the effect of the initial phase caused by the length difference between the sensing arm and the reference one on the measurement sensitivity. It suggests that the smaller the initial phase induced by the arm length difference, the higher the measurement sensitivity is. Experimental results show that the system utilizing lasers as optical carriers can greatly reduce the initial phase and the measurement sensitivity is more than twice that of the system using broadband light source acting as carrier in a 3 GHz bandwidth. The measurement accuracy is 4 μm and the measurement range is more than 40 mm, as well as the stability is within ±2 μm. As a result, the proposed displacement measurement system possesses the merits of wide measurement range, high sensitivity and high accuracy, which offers great potentials in the fields of precise displacement measurement.
- 13 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (21) , 6838-6843
Distributed Bending Sensing of Few-Mode Fiber Based on Optical Frequency Domain Reflectometry
A novel scheme to realize distributed bending sensing along the few mode fiber based on optical frequency domain reflectometry is proposed. The feasibility of the proposed method has been demonstrated both theoretically and experimentally on a two-mode fiber. The bending information is obtained by demodulating the changes of the effective refractive index and differential mode delay between LP 01 and LP 11 modes. The experimental results are in good agreement with those obtained by simulation when the bending diameter changes from 4 to 8 cm. We believe that this characterization method paves the way for developing high spatial resolution distributed bending sensor and can also be generalized to more modes case.
- 13 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 41 (21) , 6838-6843
Distributed Bending Sensing of Few-Mode Fiber Based on Optical Frequency Domain Reflectometry
A novel scheme to realize distributed bending sensing along the few mode fiber based on optical frequency domain reflectometry is proposed. The feasibility of the proposed method has been demonstrated both theoretically and experimentally on a two-mode fiber. The bending information is obtained by demodulating the changes of the effective refractive index and differential mode delay between LP 01 and LP 11 modes. The experimental results are in good agreement with those obtained by simulation when the bending diameter changes from 4 to 8 cm. We believe that this characterization method paves the way for developing high spatial resolution distributed bending sensor and can also be generalized to more modes case.
- Open Access
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 15 (1) , 1-9
Highly Precise Magnetic Field Measurement Based RF-Assisted Sagnac Interferometer With Tapered Fiber
A radio frequency (RF)-assisted Sagnac interferometer based on a dual-loop optoelectronic oscillator (OEO) is experimentally demonstrated for high-precision magnetic field measurement, in which the tapered fiber covered with the magnetic fluid (MF) as the magnetic field sensing head is embedded in the Sagnac interferometer. The evanescent field of the tapered fiber can interact with the MF under the external magnetic field to cause the birefringence variation of the fundamental mode, leading to the change in the free spectral range (FSR) of the interferometer, which can be mapped to the oscillation frequency shift of the OEO in the microwave domain. By the above converting, the magnetic field measurement with high interrogation speed and resolution can be realized. In addition, the designed device shows a certain measurement directionality of the magnetic field due to two orthogonally polarized fundamental modes asymmetric to the magnetic field, obtaining a good conformity with the constructed theoretical models. The experimental results show the maximum magnetic field sensitivities of 159.4 Hz/mT in the range of 8.48-27.83 mT, and 350.8 Hz/mT in the range of 0-5.14 mT, corresponding to the light wave vector parallel and perpendicular to the magnetic field, respectively.
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 15 (1) , 1-9
Open AccessHighly Precise Magnetic Field Measurement Based RF-Assisted Sagnac Interferometer With Tapered Fiber
A radio frequency (RF)-assisted Sagnac interferometer based on a dual-loop optoelectronic oscillator (OEO) is experimentally demonstrated for high-precision magnetic field measurement, in which the tapered fiber covered with the magnetic fluid (MF) as the magnetic field sensing head is embedded in the Sagnac interferometer. The evanescent field of the tapered fiber can interact with the MF under the external magnetic field to cause the birefringence variation of the fundamental mode, leading to the change in the free spectral range (FSR) of the interferometer, which can be mapped to the oscillation frequency shift of the OEO in the microwave domain. By the above converting, the magnetic field measurement with high interrogation speed and resolution can be realized. In addition, the designed device shows a certain measurement directionality of the magnetic field due to two orthogonally polarized fundamental modes asymmetric to the magnetic field, obtaining a good conformity with the constructed theoretical models. The experimental results show the maximum magnetic field sensitivities of 159.4 Hz/mT in the range of 8.48-27.83 mT, and 350.8 Hz/mT in the range of 0-5.14 mT, corresponding to the light wave vector parallel and perpendicular to the magnetic field, respectively.
- 10 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (3) , 909-917
Highly Sensitive Magnetic Field Measurement With Taper-Based In-Line Mach-Zehnder Interferometer and Vernier Effect
A taper-based in-line Mach-Zehnder interferometer (MZI) coated with the magnetic fluids (MFs) is designed and experimentally verified for the highly sensitive magnetic field measurement. The effect of waist diameter on the characteristic parameters of transmission modes is numerically analyzed by the finite element method (FEM). The sensing MZI (S-MZI) with a waist diameter of ∼8.92 μm is fabricated, in which the multi-mode interference occurs between the fundamental mode (HE11) and cladding modes (HE21 and TM01 modes). The S-MZI has the average sensitivities of 1.180 and 1.305 nm/mT near 1550 nm as the magnetic field increases and decreases in the range of 10.15∼30.44 mT. In order to further improve the measurement sensitivity of the magnetic field, a cascaded MZI (C-MZI) based on the Vernier effect is proposed, which is composed of a reference MZI (R-MZI) without MFs connected in series with the above S-MZI. An evident envelope and shift influenced by the external magnetic field is observed in the transmission spectra of the C-MZI, resulting in the sensitivity being elevated by an amplification factor. The C-MZI shows the average sensitivities of −5.148 and −5.782 nm/mT near 1500 nm, respectively, being ∼4.77 and 4.83 times of those in the single S-MZI. Therefore, the proposed device may have broad applications in the magnetic field measurement in view of the advantages of high sensitivity, low cost, small volume, and simple fabrication.
- 10 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (3) , 909-917
Highly Sensitive Magnetic Field Measurement With Taper-Based In-Line Mach-Zehnder Interferometer and Vernier Effect
A taper-based in-line Mach-Zehnder interferometer (MZI) coated with the magnetic fluids (MFs) is designed and experimentally verified for the highly sensitive magnetic field measurement. The effect of waist diameter on the characteristic parameters of transmission modes is numerically analyzed by the finite element method (FEM). The sensing MZI (S-MZI) with a waist diameter of ∼8.92 μm is fabricated, in which the multi-mode interference occurs between the fundamental mode (HE11) and cladding modes (HE21 and TM01 modes). The S-MZI has the average sensitivities of 1.180 and 1.305 nm/mT near 1550 nm as the magnetic field increases and decreases in the range of 10.15∼30.44 mT. In order to further improve the measurement sensitivity of the magnetic field, a cascaded MZI (C-MZI) based on the Vernier effect is proposed, which is composed of a reference MZI (R-MZI) without MFs connected in series with the above S-MZI. An evident envelope and shift influenced by the external magnetic field is observed in the transmission spectra of the C-MZI, resulting in the sensitivity being elevated by an amplification factor. The C-MZI shows the average sensitivities of −5.148 and −5.782 nm/mT near 1500 nm, respectively, being ∼4.77 and 4.83 times of those in the single S-MZI. Therefore, the proposed device may have broad applications in the magnetic field measurement in view of the advantages of high sensitivity, low cost, small volume, and simple fabrication.
- 27 September 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (28) , 8350-8358
Highly sensitive dual-core photonic crystal fiber based on a surface plasmon resonance sensor with a silver nano-continuous grating
Two kinds of photonic crystal fiber (PCF) sensors based on surface plasmon resonance (SPR) with silver nano-continuous gratings (i) and (ii) are designed. The coupling characteristics and sensing properties are analyzed numerically by the finite element method (FEM). The results show that the proposed sensor based on silver nano-continuous grating (i) can achieve better performance than that of the sensors based on silver nano-continuous grating (ii) and plane silver film structures. When the segmented number is 50 and segmented angle is 0.5°, a wavelength sensitivity of the proposed sensor with silver nano-continuous grating (i) is obtained as high as 13,600 nm/RIU in the refractive index (RI) range from 1.330 to 1.365, corresponding to a maximum RI resolution of , which can have promising applications in medical and environmental monitoring and biochemical detection.- 27 September 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (28) , 8350-8358
Highly sensitive dual-core photonic crystal fiber based on a surface plasmon resonance sensor with a silver nano-continuous grating
Two kinds of photonic crystal fiber (PCF) sensors based on surface plasmon resonance (SPR) with silver nano-continuous gratings (i) and (ii) are designed. The coupling characteristics and sensing properties are analyzed numerically by the finite element method (FEM). The results show that the proposed sensor based on silver nano-continuous grating (i) can achieve better performance than that of the sensors based on silver nano-continuous grating (ii) and plane silver film structures. When the segmented number is 50 and segmented angle is 0.5°, a wavelength sensitivity of the proposed sensor with silver nano-continuous grating (i) is obtained as high as 13,600 nm/RIU in the refractive index (RI) range from 1.330 to 1.365, corresponding to a maximum RI resolution of , which can have promising applications in medical and environmental monitoring and biochemical detection.- 7 September 2018
- Published by Springer Nature in Plasmonics
- Vol. 14 (3) , 685-693
Analysis of Dual-Core Photonic Crystal Fiber Based on Surface Plasmon Resonance Sensor with Segmented Silver Film
- 7 September 2018
- Published by Springer Nature in Plasmonics
- Vol. 14 (3) , 685-693