Miroslav Husák
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Miroslav Husák has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Kromka
Institute of Physics of the Czech Academy of Sciences Prague Czech Republic
3 shared publications - Alexandr Laposa
Department of Microelectronics, Czech Technical University in Prague, Technicka 2,166 27 Prague, Czech Republic
2 shared publications - Jiri Jakovenko
Czech Technical University
2 shared publications - Jiri Kroutil
Department of Microelectronics, Czech Technical University in Prague, Technicka 2,166 27 Prague, Czech Republic
2 shared publications - Marian Varga
Institute of Electrical Engineering, Slovak Academy of Sciences
2 shared publications - Michal Kočí
Department of Semiconductors, Institute of Physics of the Czech Academy of Sciences, Cukrovarnická 10/112, Prague 6 162 00, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 21 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (9) , 14703-14715
Highly Sensitive Gas and Ethanol Vapor Sensors Based on Carbon Heterostructures for Room Temperature Detection
Graphene oxides (GOs) and hydrogen-terminated nanocrystalline diamonds (H-NCD) have attracted considerable attention due to their unique electronic structure and extraordinary physical and chemical properties in various applications, including gas sensing. Currently, there is a significant focus on air quality and the presence of pollutants (NH3, NO2, etc.), as well as volatile organic compounds (VOC) such as ethanol vapor from industry. This study examines the synthesis of GO, reduced graphene oxide (rGO), thiol-functionalized graphene oxide (SH-GO), and H-NCD thin films and their combination in heterostructures. The materials were analyzed for their ability to detect NO2, NH3, and ethanol vapor at room temperature (22 °C). Among the tested materials, the SH-GO/H-NCD heterostructure exhibited the highest sensitivity, with approximately 630% for ethanol vapor, 41% for NH3 and -19% for NO2. The SH-GO/H-NCD heterostructure also demonstrated reasonable response (272 s) and recovery (34 s) times. Cross-selectivity measurements revealed that the heterostructure's response to ethanol vapor at 100 ppm remained dominant and was minimally affected by the presence of NH3 (100 ppm) or CO2 (100 ppm). The response variations were -1.3% for NO2 and 2.4% for NH3, respectively. These findings suggest that this heterostructure has the potential to be used as an active layer in low-temperature gas sensors. Furthermore, this research proposes a primary mechanism that explains the enhanced sensor response of the heterostructure compared with bare GOs and H-NCD layers.
- 21 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (9) , 14703-14715
Open AccessHighly Sensitive Gas and Ethanol Vapor Sensors Based on Carbon Heterostructures for Room Temperature Detection
Graphene oxides (GOs) and hydrogen-terminated nanocrystalline diamonds (H-NCD) have attracted considerable attention due to their unique electronic structure and extraordinary physical and chemical properties in various applications, including gas sensing. Currently, there is a significant focus on air quality and the presence of pollutants (NH3, NO2, etc.), as well as volatile organic compounds (VOC) such as ethanol vapor from industry. This study examines the synthesis of GO, reduced graphene oxide (rGO), thiol-functionalized graphene oxide (SH-GO), and H-NCD thin films and their combination in heterostructures. The materials were analyzed for their ability to detect NO2, NH3, and ethanol vapor at room temperature (22 °C). Among the tested materials, the SH-GO/H-NCD heterostructure exhibited the highest sensitivity, with approximately 630% for ethanol vapor, 41% for NH3 and -19% for NO2. The SH-GO/H-NCD heterostructure also demonstrated reasonable response (272 s) and recovery (34 s) times. Cross-selectivity measurements revealed that the heterostructure's response to ethanol vapor at 100 ppm remained dominant and was minimally affected by the presence of NH3 (100 ppm) or CO2 (100 ppm). The response variations were -1.3% for NO2 and 2.4% for NH3, respectively. These findings suggest that this heterostructure has the potential to be used as an active layer in low-temperature gas sensors. Furthermore, this research proposes a primary mechanism that explains the enhanced sensor response of the heterostructure compared with bare GOs and H-NCD layers.
- Open Access
- 3 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (28) , 34206-34214
Improved Gas Sensing Capabilities of MoS2/Diamond Heterostructures at Room Temperature
Molybdenum disulfide (MoS2) and nanocrystalline diamond (NCD) have attracted considerable attention due to their unique electronic structure and extraordinary physical and chemical properties in many applications, including sensor devices in gas sensing applications. Combining MoS2 and H-terminated NCD (H-NCD) in a heterostructure design can improve the sensing performance due to their mutual advantages. In this study, the synthesis of MoS2 and H-NCD thin films using appropriate physical/chemical deposition methods and their analysis in terms of gas sensing properties in their individual and combined forms are demonstrated. The sensitivity and time domain characteristics of the sensors were investigated for three gases: oxidizing NO2, reducing NH3, and neutral synthetic air. It was observed that the MoS2/H-NCD heterostructure-based gas sensor exhibits improved sensitivity to oxidizing NO2 (0.157%·ppm-1) and reducing NH3 (0.188%·ppm-1) gases compared to pure active materials (pure MoS2 achieves responses of 0.018%·ppm-1 for NO2 and -0.0072%·ppm-1 for NH3, respectively, and almost no response for pure H-NCD at room temperature). Different gas interaction model pathways were developed to describe the current flow mechanism through the sensing area with/without the heterostructure. The gas interaction model independently considers the influence of each material (chemisorption for MoS2 and surface doping mechanism for H-NCD) as well as the current flow mechanism through the formed P-N heterojunction.
- 3 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (28) , 34206-34214
Open AccessImproved Gas Sensing Capabilities of MoS2/Diamond Heterostructures at Room Temperature
Molybdenum disulfide (MoS2) and nanocrystalline diamond (NCD) have attracted considerable attention due to their unique electronic structure and extraordinary physical and chemical properties in many applications, including sensor devices in gas sensing applications. Combining MoS2 and H-terminated NCD (H-NCD) in a heterostructure design can improve the sensing performance due to their mutual advantages. In this study, the synthesis of MoS2 and H-NCD thin films using appropriate physical/chemical deposition methods and their analysis in terms of gas sensing properties in their individual and combined forms are demonstrated. The sensitivity and time domain characteristics of the sensors were investigated for three gases: oxidizing NO2, reducing NH3, and neutral synthetic air. It was observed that the MoS2/H-NCD heterostructure-based gas sensor exhibits improved sensitivity to oxidizing NO2 (0.157%·ppm-1) and reducing NH3 (0.188%·ppm-1) gases compared to pure active materials (pure MoS2 achieves responses of 0.018%·ppm-1 for NO2 and -0.0072%·ppm-1 for NH3, respectively, and almost no response for pure H-NCD at room temperature). Different gas interaction model pathways were developed to describe the current flow mechanism through the sensing area with/without the heterostructure. The gas interaction model independently considers the influence of each material (chemisorption for MoS2 and surface doping mechanism for H-NCD) as well as the current flow mechanism through the formed P-N heterojunction.
- Open Access
- 1 January 2016
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 67 (1) , 61-64
Quartz Crystal Micro–Balance Gas Sensor with Ink–Jet Printed Nano–Diamond Sensitive Layer
The paper presents fabrication and characterization of a Quartz Crystal Microbalance based gas sensor with a diamond powder sensitive layer deposited using the ink-jet printing technique. The sensor was exposed to a low concentration of ammonia, acetone vapors and different levels of humidity. Impedance characteristics close to the natural resonant frequency of 10 MHz were examined. The sensor exhibits significant shifts in serial resonant frequency under different gas environments.
- 1 January 2016
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 67 (1) , 61-64
Open AccessQuartz Crystal Micro–Balance Gas Sensor with Ink–Jet Printed Nano–Diamond Sensitive Layer
The paper presents fabrication and characterization of a Quartz Crystal Microbalance based gas sensor with a diamond powder sensitive layer deposited using the ink-jet printing technique. The sensor was exposed to a low concentration of ammonia, acetone vapors and different levels of humidity. Impedance characteristics close to the natural resonant frequency of 10 MHz were examined. The sensor exhibits significant shifts in serial resonant frequency under different gas environments.
- 3 April 2014
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 605, 589-592
Fabrication of Diamond Based Quartz Crystal Microbalance Gas Sensor
Synthetic diamond has remarkable properties comparable with natural diamond and hence is a very promising material for many various applications (sensors, heat sink, optical mirrors, cold cathode, tissue engineering, etc.). Nowadays, deposition of diamond films is normally employed in chemical vapor deposition (CVD) usually at high temperatures (800900 °C), what limit its application to high melting substrates. Gravimetric (mass) sensors belong to the major categories of chemical sensors and the most common type of mass sensor is the bulk acoustic quartz crystal microbalance (QCM). This contribution deals with a nanocrystalline diamond (NCD) growth from the H2/CH4/CO2 gas mixture at low temperature (400 °C) by pulsed linear antenna microwave plasma system on 10 MHz circular AT-cut quartz resonators substrate. Gas sensor based on the NCD-coated QCM was developed for detection of ammonia (NH3) at room temperature. Measurements not only confirmed the functionality of this first published NCD-coated QCM sensor, but in addition its sensitivity was twofold to a virgin QCM sensor with a gold active layer.
- 3 April 2014
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 605, 589-592
Fabrication of Diamond Based Quartz Crystal Microbalance Gas Sensor
Synthetic diamond has remarkable properties comparable with natural diamond and hence is a very promising material for many various applications (sensors, heat sink, optical mirrors, cold cathode, tissue engineering, etc.). Nowadays, deposition of diamond films is normally employed in chemical vapor deposition (CVD) usually at high temperatures (800900 °C), what limit its application to high melting substrates. Gravimetric (mass) sensors belong to the major categories of chemical sensors and the most common type of mass sensor is the bulk acoustic quartz crystal microbalance (QCM). This contribution deals with a nanocrystalline diamond (NCD) growth from the H2/CH4/CO2 gas mixture at low temperature (400 °C) by pulsed linear antenna microwave plasma system on 10 MHz circular AT-cut quartz resonators substrate. Gas sensor based on the NCD-coated QCM was developed for detection of ammonia (NH3) at room temperature. Measurements not only confirmed the functionality of this first published NCD-coated QCM sensor, but in addition its sensitivity was twofold to a virgin QCM sensor with a gold active layer.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 167-170
Detection of Breathing
Acoustic signals originate by the flow of air through the trachea during breathing. These signals are possible to pick-up by microphone. This paper describes a method of the breathing detection based on the sensing of acoustic signals in trachea. Parameters of the breathing, detection inspiration and expiration and apnoea pause are possible to determine from these signals. This method is simple and easy to use, portable and provides an accurate measurement and seems to be well suited for use as a modern breathing monitor.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 167-170
Detection of Breathing
Acoustic signals originate by the flow of air through the trachea during breathing. These signals are possible to pick-up by microphone. This paper describes a method of the breathing detection based on the sensing of acoustic signals in trachea. Parameters of the breathing, detection inspiration and expiration and apnoea pause are possible to determine from these signals. This method is simple and easy to use, portable and provides an accurate measurement and seems to be well suited for use as a modern breathing monitor.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 83-86
NMOS and PMOS Translinear Multiplying Cell for Current-Mode Signal Processing
The paper describes NMOS and PMOS translinear cell which multiplies the current signals and which can be used for the current-mode signal processing. The translinear cell consists of NMOS or PMOS transistors that are treated in the sub-threshold conduction region. In this region the transistors exhibit an exponential dependency of the drain current versus the gate voltage and thus the translinear principle can be used for description of the functionality. Operation region of the cell is limited by the validity of the exponential dependency and also by the transistors leakage currents. Significant error is also induced by the auxiliary current mirrors which are biasing the cells. Channel length modulation effect causes error of the input signals and thus the output signal is affected by the multiplicative error. The paper presents basic idea of the multiplying cell, presents results of simulations in CADENCE and also presents results of measurements on real structure composed using discrete transistors.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 83-86
NMOS and PMOS Translinear Multiplying Cell for Current-Mode Signal Processing
The paper describes NMOS and PMOS translinear cell which multiplies the current signals and which can be used for the current-mode signal processing. The translinear cell consists of NMOS or PMOS transistors that are treated in the sub-threshold conduction region. In this region the transistors exhibit an exponential dependency of the drain current versus the gate voltage and thus the translinear principle can be used for description of the functionality. Operation region of the cell is limited by the validity of the exponential dependency and also by the transistors leakage currents. Significant error is also induced by the auxiliary current mirrors which are biasing the cells. Channel length modulation effect causes error of the input signals and thus the output signal is affected by the multiplicative error. The paper presents basic idea of the multiplying cell, presents results of simulations in CADENCE and also presents results of measurements on real structure composed using discrete transistors.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 177-180
Direction Sensitivity Matrix with PLL Temperature Sensor
In the paper there is presented temperature transducer with PLL signal processing of sensor data. The principle of temperature sensor is based on the MOS structure behaviour in the temperature range. The strong and weak inversion modes are used. There is used matrix of temperature sensors in the design of air flow sensor. Various arrangements of temperature structure are designed. The new circuits design is used
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 177-180
Direction Sensitivity Matrix with PLL Temperature Sensor
In the paper there is presented temperature transducer with PLL signal processing of sensor data. The principle of temperature sensor is based on the MOS structure behaviour in the temperature range. The strong and weak inversion modes are used. There is used matrix of temperature sensors in the design of air flow sensor. Various arrangements of temperature structure are designed. The new circuits design is used
- 1 January 2006
- Published by Springer Nature
- p. 383-443
GaAs Thermally Based MEMS Devices—Fabrication Techniques, Characterization and Modeling
- 1 January 2006
- Published by Springer Nature
- p. 383-443
GaAs Thermally Based MEMS Devices—Fabrication Techniques, Characterization and Modeling
- 1 January 2000
- Published by Springer Nature
- p. 269-272
Microsystem Project-Oriented Education