Benedikt Helgason
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Benedikt Helgason has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Stephen J. Ferguson
Future Health Technologies, Singapore-ETH Centre, Campus for Research Excellence And Technological Enterprise (CREATE)
7 shared publications - Peter Alec Cripton
Orthopaedic and Injury Biomechanics Group, Departments of Mechanical Engineering and Orthopaedics; School of Biomedical Engineering; ICORD, University of British Columbia, Vancouver, BC, Canada
5 shared publications - Pierre Guy
Division of Orthopedic Trauma, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
4 shared publications O. Ariza
Institute for Biomechanics, ETH-Zürich, HPP-O12, Hönggerbergring 64, CH-8093 Zürich, Switzerland; Orthopaedic and Injury Biomechanics Group; Centre for Hip Health and Mobility; Department of Mechanical Engineering
3 shared publicationsR.P. Widmer
Institute for Biomechanics, ETH-Zürich, HPP-O12, Hönggerbergring 64, CH-8093 Zürich, Switzerland
3 shared publications- Halldor Palsson
Faculty of Industrial Engineering, Mechanical Engineering and Computer Science, School of Engineering and Natural Sciences, University of Iceland, Reykjavik, Iceland
2 shared publications
Latest Publications
- Open Access
- 14 May 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 126, 106556
High-speed x-ray characterizes fracture incidence and bone-implant motion during a fall from standing
- 14 May 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 126, 106556
Open AccessHigh-speed x-ray characterizes fracture incidence and bone-implant motion during a fall from standing
- 1 January 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 65, 801-807
Comparison of specimen-specific vertebral body finite element models with experimental digital image correlation measurements
- 1 January 2017
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 65, 801-807
Comparison of specimen-specific vertebral body finite element models with experimental digital image correlation measurements
- Open Access
- 12 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (7) , 679-689
The influence of the modulus–density relationship and the material mapping method on the simulated mechanical response of the proximal femur in side-ways fall loading configuration
Contributing to slow advance of finite element (FE) simulations for hip fracture risk prediction, into clinical practice, could be a lack of consensus in the biomechanics community on how to map properties to the models. Thus, the aim of the present study was first, to systematically quantify the influence of the modulus-density relationship (E-ρ) and the material mapping method (MMM) on the predicted mechanical response of the proximal femur in a side-ways fall (SWF) loading configuration and second, to perform a model-to-model comparison of the predicted mechanical response within the femoral neck for all the specimens tested in the present study, using three different modelling techniques that have yielded good validation outcome in terms of surface strain prediction and whole bone response according to the literature. We found the outcome to be highly dependent on both the E-ρ relationship and the MMM. In addition, we found that the three modelling techniques that have resulted in good validation outcome in the literature yielded different principal strain prediction both on the surface as well as internally in the femoral neck region of the specimens modelled in the present study. We conclude that there exists a need to carry out a more comprehensive validation study for the SWF loading mode to identify which combination of MMMs and E-ρ relationship leads to the best match for whole bone and local mechanical response. The MMMs tested in the present study have been made publicly available at https://simtk.org/home/mitk-gem.
- 12 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (7) , 679-689
Open AccessThe influence of the modulus–density relationship and the material mapping method on the simulated mechanical response of the proximal femur in side-ways fall loading configuration
Contributing to slow advance of finite element (FE) simulations for hip fracture risk prediction, into clinical practice, could be a lack of consensus in the biomechanics community on how to map properties to the models. Thus, the aim of the present study was first, to systematically quantify the influence of the modulus-density relationship (E-ρ) and the material mapping method (MMM) on the predicted mechanical response of the proximal femur in a side-ways fall (SWF) loading configuration and second, to perform a model-to-model comparison of the predicted mechanical response within the femoral neck for all the specimens tested in the present study, using three different modelling techniques that have yielded good validation outcome in terms of surface strain prediction and whole bone response according to the literature. We found the outcome to be highly dependent on both the E-ρ relationship and the MMM. In addition, we found that the three modelling techniques that have resulted in good validation outcome in the literature yielded different principal strain prediction both on the surface as well as internally in the femoral neck region of the specimens modelled in the present study. We conclude that there exists a need to carry out a more comprehensive validation study for the SWF loading mode to identify which combination of MMMs and E-ρ relationship leads to the best match for whole bone and local mechanical response. The MMMs tested in the present study have been made publicly available at https://simtk.org/home/mitk-gem.
- Open Access
- 21 April 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (4) , e0151680
The Effectiveness of Percutaneous Vertebroplasty Is Determined by the Patient-Specific Bone Condition and the Treatment Strategy
Vertebral fragility fractures are often treated by injecting bone cement into the collapsed vertebral bodies (vertebroplasty). The mechanisms by which vertebroplasty induces pain relief are not completely understood yet and recent debates cast doubt over the outcome of the procedure. The controversy is intensified by inconsistent results of randomized clinical trials and biomechanical studies that have investigated the effectiveness or the change in biomechanical response due to the reinforcement. The purpose of this study was to evaluate the effectiveness of vertebroplasty, by varying the relevant treatment parameters and (a) computationally predicting the improvement of the fracture risk depending on the chosen treatment strategy, and (b) identifying the determinants of a successful treatment. A Finite Element model with a patient-specific failure criterion and direct simulation of PMMA infiltration in four lumbar vertebrae was used to assess the condition of the bone under compressive load before and after the virtual treatment, simulating in a total of 12000 virtual treatments. The results showed that vertebroplasty is capable of reducing the fracture risk by magnitudes, but can also have a detrimental effect. Effectiveness was strongly influenced by interactions between local bone quality, cement volume and injection location. However, only a moderate number of the investigated treatment strategies were able to achieve the necessary improvement for preventing a fracture. We conclude that the effectiveness of vertebroplasty is sensitive to the patient’s condition and the treatment strategy.
- 21 April 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (4) , e0151680
Open AccessThe Effectiveness of Percutaneous Vertebroplasty Is Determined by the Patient-Specific Bone Condition and the Treatment Strategy
Vertebral fragility fractures are often treated by injecting bone cement into the collapsed vertebral bodies (vertebroplasty). The mechanisms by which vertebroplasty induces pain relief are not completely understood yet and recent debates cast doubt over the outcome of the procedure. The controversy is intensified by inconsistent results of randomized clinical trials and biomechanical studies that have investigated the effectiveness or the change in biomechanical response due to the reinforcement. The purpose of this study was to evaluate the effectiveness of vertebroplasty, by varying the relevant treatment parameters and (a) computationally predicting the improvement of the fracture risk depending on the chosen treatment strategy, and (b) identifying the determinants of a successful treatment. A Finite Element model with a patient-specific failure criterion and direct simulation of PMMA infiltration in four lumbar vertebrae was used to assess the condition of the bone under compressive load before and after the virtual treatment, simulating in a total of 12000 virtual treatments. The results showed that vertebroplasty is capable of reducing the fracture risk by magnitudes, but can also have a detrimental effect. Effectiveness was strongly influenced by interactions between local bone quality, cement volume and injection location. However, only a moderate number of the investigated treatment strategies were able to achieve the necessary improvement for preventing a fracture. We conclude that the effectiveness of vertebroplasty is sensitive to the patient’s condition and the treatment strategy.
- 1 January 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (2) , 224-232
Comparison of explicit finite element and mechanical simulation of the proximal femur during dynamic drop-tower testing
- 1 January 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (2) , 224-232
Comparison of explicit finite element and mechanical simulation of the proximal femur during dynamic drop-tower testing
- 12 March 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (6) , 793-799
Development of a balanced experimental–computational approach to understanding the mechanics of proximal femur fractures
The majority of people who sustain hip fractures after a fall to the side would not have been identified using current screening techniques such as areal bone mineral density. Identifying them, however, is essential so that appropriate pharmacological or lifestyle interventions can be implemented. A protocol, demonstrated on a single specimen, is introduced, comprising the following components; in vitro biofidelic drop tower testing of a proximal femur; high-speed image analysis through digital image correlation; detailed accounting of the energy present during the drop tower test; organ level finite element simulations of the drop tower test; micro level finite element simulations of critical volumes of interest in the trabecular bone. Fracture in the femoral specimen initiated in the superior part of the neck. Measured fracture load was 3760N, compared to 4871N predicted based on the finite element analysis. Digital image correlation showed compressive surface strains as high as 7.1% prior to fracture. Voxel level results were consistent with high-speed video data and helped identify hidden local structural weaknesses. We found using a drop tower test protocol that a femoral neck fracture can be created with a fall velocity and energy representative of a sideways fall from standing. Additionally, we found that the nested explicit finite element method used allowed us to identify local structural weaknesses associated with femur fracture initiation.
- 12 March 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (6) , 793-799
Development of a balanced experimental–computational approach to understanding the mechanics of proximal femur fractures
The majority of people who sustain hip fractures after a fall to the side would not have been identified using current screening techniques such as areal bone mineral density. Identifying them, however, is essential so that appropriate pharmacological or lifestyle interventions can be implemented. A protocol, demonstrated on a single specimen, is introduced, comprising the following components; in vitro biofidelic drop tower testing of a proximal femur; high-speed image analysis through digital image correlation; detailed accounting of the energy present during the drop tower test; organ level finite element simulations of the drop tower test; micro level finite element simulations of critical volumes of interest in the trabecular bone. Fracture in the femoral specimen initiated in the superior part of the neck. Measured fracture load was 3760N, compared to 4871N predicted based on the finite element analysis. Digital image correlation showed compressive surface strains as high as 7.1% prior to fracture. Voxel level results were consistent with high-speed video data and helped identify hidden local structural weaknesses. We found using a drop tower test protocol that a femoral neck fracture can be created with a fall velocity and energy representative of a sideways fall from standing. Additionally, we found that the nested explicit finite element method used allowed us to identify local structural weaknesses associated with femur fracture initiation.
- 19 November 2012
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101B (2) , 364-374
Influence of cement stiffness and bone morphology on the compressive properties of bone–cement composites in simulated vertebroplasty
Vertebroplasty is widely used to treat vertebral compression fractures. Little is known about the influence of morphological parameters of the bone on the properties of the bone–cement composite. Furthermore, although generic finite element (FE) models have been suggested as a way to compute the values of these properties, their accuracy has not been established. In the experimental part of this study, we tested bovine cancellous bone and three different polymethylmethacrylate bone cements and determined six quasi‐static uniaxial compressive properties of bone–cement composite specimens and 10 morphological parameters of the bone. For the FE work, we used two simulations, one being μFE and the other unit cell FE. In conclusion, we found that (1) for composite specimens, that relative contribution of the cement to the overall response of the composite increases with increasing cement stiffness; (2) the anisotropy ratio is the bone morphological property that exerts the most significant influence on the experimentally obtained compressive properties of the bone–cement composites determined; (3) the accuracy of the computed compressive properties of the composites ranged from low to high, depending on simulation method used. The largest errors, however, can partially be explained by difference in boundary conditions between the experimental testing and the simulation techniques. The lattermost finding points to the potential for simplified FE models being incorporated into automatic material mapping schemes in whole bone vertebra FE simulations. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
- 19 November 2012
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101B (2) , 364-374
Influence of cement stiffness and bone morphology on the compressive properties of bone–cement composites in simulated vertebroplasty
Vertebroplasty is widely used to treat vertebral compression fractures. Little is known about the influence of morphological parameters of the bone on the properties of the bone–cement composite. Furthermore, although generic finite element (FE) models have been suggested as a way to compute the values of these properties, their accuracy has not been established. In the experimental part of this study, we tested bovine cancellous bone and three different polymethylmethacrylate bone cements and determined six quasi‐static uniaxial compressive properties of bone–cement composite specimens and 10 morphological parameters of the bone. For the FE work, we used two simulations, one being μFE and the other unit cell FE. In conclusion, we found that (1) for composite specimens, that relative contribution of the cement to the overall response of the composite increases with increasing cement stiffness; (2) the anisotropy ratio is the bone morphological property that exerts the most significant influence on the experimentally obtained compressive properties of the bone–cement composites determined; (3) the accuracy of the computed compressive properties of the composites ranged from low to high, depending on simulation method used. The largest errors, however, can partially be explained by difference in boundary conditions between the experimental testing and the simulation techniques. The lattermost finding points to the potential for simplified FE models being incorporated into automatic material mapping schemes in whole bone vertebra FE simulations. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
- Open Access
- 3 September 2012
- Published by PAGEPress Publications in European Journal of Translational Myology
- Vol. 22 (3) , 147-152
Bone and muscle assessment in patients undergoing total hip arthroplasty using HU based analysis
Total hip arthroplasty (THA) is performed with or without the use of bone cement. The lack of reliable clinical guidelines for deciding which one to implement has encouraged this approach of joint clinical and engineering with the following objectives: 1. Validate quadriceps muscles and femur bone atrophy by extracting the mineral density from Computer Tomographic (CT) images. 2. Validate computational processes based on 3-D modeling and Finite Element Methods (FEM). A clinical trial was started, where 36 volunteer patients underwent THA surgery for the first time: 18 receiving cemented implant and 18 receiving uncemented implant. The patients were CT scanned prior-, immediately after and 12 months post-surgery. The CT data are further processed to segment muscles and bones and to create 3D-models for the simulation and for calculating bone mineral density (BMD). Furthermore quadriceps muscle density Hounsfield (HU) based value is calculated from the segmented file on healthy and operated leg. These preliminary results indicate computational tools and methods that are able to quantitatively analyse patient’s condition pre and post-surgery. The BMD and muscle density measurement in correlation with the fracture risk analysis display a potential method for eligibility to receive non-cemented implant; the preliminary results show that also elderly that according with current clinical evaluation receives a cemented implant are suitable for the non-cemented type. The risk for structural failure during THA surgery is estimated by calculating femoral bone fracture risk index (FRI) as a ratio between compressive stress during surgery and estimated failure stress on bone. The correlations with the BMD observations during the clinical trial will assess and validate this potential predictor tool.
- 3 September 2012
- Published by PAGEPress Publications in European Journal of Translational Myology
- Vol. 22 (3) , 147-152
Open AccessBone and muscle assessment in patients undergoing total hip arthroplasty using HU based analysis
Total hip arthroplasty (THA) is performed with or without the use of bone cement. The lack of reliable clinical guidelines for deciding which one to implement has encouraged this approach of joint clinical and engineering with the following objectives: 1. Validate quadriceps muscles and femur bone atrophy by extracting the mineral density from Computer Tomographic (CT) images. 2. Validate computational processes based on 3-D modeling and Finite Element Methods (FEM). A clinical trial was started, where 36 volunteer patients underwent THA surgery for the first time: 18 receiving cemented implant and 18 receiving uncemented implant. The patients were CT scanned prior-, immediately after and 12 months post-surgery. The CT data are further processed to segment muscles and bones and to create 3D-models for the simulation and for calculating bone mineral density (BMD). Furthermore quadriceps muscle density Hounsfield (HU) based value is calculated from the segmented file on healthy and operated leg. These preliminary results indicate computational tools and methods that are able to quantitatively analyse patient’s condition pre and post-surgery. The BMD and muscle density measurement in correlation with the fracture risk analysis display a potential method for eligibility to receive non-cemented implant; the preliminary results show that also elderly that according with current clinical evaluation receives a cemented implant are suitable for the non-cemented type. The risk for structural failure during THA surgery is estimated by calculating femoral bone fracture risk index (FRI) as a ratio between compressive stress during surgery and estimated failure stress on bone. The correlations with the BMD observations during the clinical trial will assess and validate this potential predictor tool.