Erica Iacob
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Erica Iacob has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Bossi
Department of Biotechnology, University of Verona, Strada le Grazie 15, 37134 Verona, Italy
2 shared publications - Ambra Vestri
Department of Biotechnology, University of Verona, Strada Le Grazie 15, 37134, Verona, Italy.
2 shared publications - Annalisa Castagna
Unit of Internal Medicine, Department of Medicine, University of Verona, 37134 Verona, Italy
2 shared publications - Damiano Giubertoni
Fondazione Bruno Kessler
2 shared publications - David Novel
Fondazione Bruno Kessler, via Sommarive 18, Povo, 38123 Trento, Italy
2 shared publications - Domenico Girelli
Section of Internal Medicine, Department of Medicine, University of Verona and Azienda Ospedaliera Universitaria Integrata di Verona, 37134 Verona, Italy
2 shared publications
Latest Publications
- Open Access
Effect of Process Parameters on the Surface Microgeometry of a Ti6Al4V Alloy Manufactured by Laser Powder Bed Fusion: 3D vs. 2D Characterization
The influence of the main process parameters, laser power, point distance and time exposure, on the surface microgeometry of Ti6Al4V specimens produced by a pulsed powder bed fusion process was investigated. A 3D characterization was carried out and collected data were elaborated to reconstruct the surface and to determine both the 3D and the 2D material ratio curves along different directions. The 3D material ratio curve gives a slightly lower material ratio of peak zone Mr1 and higher material ratio of valley zone Mr2, reduced peak height Rpk and reduced valley height Rvk than the 2D curves. Roughness is greater in the 3D analysis than in the 2D one, skewness is the same and kurtosis increases from 3 in 3D. Roughness and skewness increase on increasing point distance and decreasing time exposure and laser power. Within the investigated ranges (27.3–71.2 J/mm3), an increase in energy density reduces the surface roughness while skewness and kurtosis are not significantly affected. The results indicate that a 3D approach allows better characterization of the surface microgeometry than a 2D one.
Open AccessEffect of Process Parameters on the Surface Microgeometry of a Ti6Al4V Alloy Manufactured by Laser Powder Bed Fusion: 3D vs. 2D Characterization
The influence of the main process parameters, laser power, point distance and time exposure, on the surface microgeometry of Ti6Al4V specimens produced by a pulsed powder bed fusion process was investigated. A 3D characterization was carried out and collected data were elaborated to reconstruct the surface and to determine both the 3D and the 2D material ratio curves along different directions. The 3D material ratio curve gives a slightly lower material ratio of peak zone Mr1 and higher material ratio of valley zone Mr2, reduced peak height Rpk and reduced valley height Rvk than the 2D curves. Roughness is greater in the 3D analysis than in the 2D one, skewness is the same and kurtosis increases from 3 in 3D. Roughness and skewness increase on increasing point distance and decreasing time exposure and laser power. Within the investigated ranges (27.3–71.2 J/mm3), an increase in energy density reduces the surface roughness while skewness and kurtosis are not significantly affected. The results indicate that a 3D approach allows better characterization of the surface microgeometry than a 2D one.
- Open Access
Optimization of a Low-Power Chemoresistive Gas Sensor: Predictive Thermal Modelling and Mechanical Failure Analysis
The substrate plays a key role in chemoresistive gas sensors. It acts as mechanical support for the sensing material, hosts the heating element and, also, aids the sensing material in signal transduction. In recent years, a significant improvement in the substrate production process has been achieved, thanks to the advances in micro- and nanofabrication for micro-electro-mechanical system (MEMS) technologies. In addition, the use of innovative materials and smaller low-power consumption silicon microheaters led to the development of high-performance gas sensors. Various heater layouts were investigated to optimize the temperature distribution on the membrane, and a suspended membrane configuration was exploited to avoid heat loss by conduction through the silicon bulk. However, there is a lack of comprehensive studies focused on predictive models for the optimization of the thermal and mechanical properties of a microheater. In this work, three microheater layouts in three membrane sizes were developed using the microfabrication process. The performance of these devices was evaluated to predict their thermal and mechanical behaviors by using both experimental and theoretical approaches. Finally, a statistical method was employed to cross-correlate the thermal predictive model and the mechanical failure analysis, aiming at microheater design optimization for gas-sensing applications.
Open AccessOptimization of a Low-Power Chemoresistive Gas Sensor: Predictive Thermal Modelling and Mechanical Failure Analysis
The substrate plays a key role in chemoresistive gas sensors. It acts as mechanical support for the sensing material, hosts the heating element and, also, aids the sensing material in signal transduction. In recent years, a significant improvement in the substrate production process has been achieved, thanks to the advances in micro- and nanofabrication for micro-electro-mechanical system (MEMS) technologies. In addition, the use of innovative materials and smaller low-power consumption silicon microheaters led to the development of high-performance gas sensors. Various heater layouts were investigated to optimize the temperature distribution on the membrane, and a suspended membrane configuration was exploited to avoid heat loss by conduction through the silicon bulk. However, there is a lack of comprehensive studies focused on predictive models for the optimization of the thermal and mechanical properties of a microheater. In this work, three microheater layouts in three membrane sizes were developed using the microfabrication process. The performance of these devices was evaluated to predict their thermal and mechanical behaviors by using both experimental and theoretical approaches. Finally, a statistical method was employed to cross-correlate the thermal predictive model and the mechanical failure analysis, aiming at microheater design optimization for gas-sensing applications.
- Open Access
- 14 November 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (22) , 8585
Free-Standing Graphene Oxide and Carbon Nanotube Hybrid Papers with Enhanced Electrical and Mechanical Performance and Their Synergy in Polymer Laminates
Hybrid nanomaterials fabricated by the heterogeneous integration of 1D (carbon nanotubes) and 2D (graphene oxide) nanomaterials showed synergy in electrical and mechanical properties. Here, we reported the infiltration of carboxylic functionalized single-walled carbon nanotubes (C-SWNT) into free-standing graphene oxide (GO) paper for better electrical and mechanical properties than native GO. The stacking arrangement of GO sheets and its alteration in the presence of C-SWNT were comprehensively explored through scanning electron microscopy, X-ray photoelectron spectroscopy (XPS) and X-ray diffraction. The C-SWNTs bridges between different GO sheets produce a pathway for the flow of electrical charges and provide a tougher hybrid system. The nanoscopic surface potential map reveals a higher work function of the individual functionalised SWNTs than surrounded GO sheets showing efficient charge exchange. We observed the enhanced conductivity up to 50 times and capacitance up to 3.5 times of the hybrid structure than the GO-paper. The laminate of polystyrene composites provided higher elastic modulus and mechanical strength when hybrid paper is used, thus paving the way for the exploitation of hybrid filler formulation in designing polymer composites.
- 14 November 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (22) , 8585
Open AccessFree-Standing Graphene Oxide and Carbon Nanotube Hybrid Papers with Enhanced Electrical and Mechanical Performance and Their Synergy in Polymer Laminates
Hybrid nanomaterials fabricated by the heterogeneous integration of 1D (carbon nanotubes) and 2D (graphene oxide) nanomaterials showed synergy in electrical and mechanical properties. Here, we reported the infiltration of carboxylic functionalized single-walled carbon nanotubes (C-SWNT) into free-standing graphene oxide (GO) paper for better electrical and mechanical properties than native GO. The stacking arrangement of GO sheets and its alteration in the presence of C-SWNT were comprehensively explored through scanning electron microscopy, X-ray photoelectron spectroscopy (XPS) and X-ray diffraction. The C-SWNTs bridges between different GO sheets produce a pathway for the flow of electrical charges and provide a tougher hybrid system. The nanoscopic surface potential map reveals a higher work function of the individual functionalised SWNTs than surrounded GO sheets showing efficient charge exchange. We observed the enhanced conductivity up to 50 times and capacitance up to 3.5 times of the hybrid structure than the GO-paper. The laminate of polystyrene composites provided higher elastic modulus and mechanical strength when hybrid paper is used, thus paving the way for the exploitation of hybrid filler formulation in designing polymer composites.
- 26 September 2015
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 21 (1) , 9-17
Experience of accreditation in a surface science laboratory
- 26 September 2015
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 21 (1) , 9-17
Experience of accreditation in a surface science laboratory
- Open Access
- 27 August 2015
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 13 (1) , 1-15
Surface plasmon resonance based on molecularly imprinted nanoparticles for the picomolar detection of the iron regulating hormone Hepcidin-25
Molecularly imprinted polymer (MIP) technique is a powerful mean to produce tailor made synthetic recognition sites. Here precipitation polymerization was exploited to produce a library of MIP nanoparticles (NPs) targeting the N terminus of the hormone Hepcidin-25, whose serum levels correlate with iron dis-metabolisms and doping. Biotinylated MIP NPs were immobilized to NeutrAvidin™ SPR sensor chip. The response of the MIP NP sensor to Hepcidin-25 was studied. Morphological analysis showed MIP NPs of 20–50 nm; MIP NP exhibited high affinity and selectivity for the target analyte: low nanomolar Kds for the interaction NP/Hepcidin-25, but none for the NP/non regulative Hepcidin-20. The MIP NP were integrated as recognition element in SPR allowing the detection of Hepcidin-25 in 3 min. Linearity was observed with the logarithm of Hepcidin-25 concentration in the range 7.2–720 pM. LOD was 5 pM. The response for Hepcidin-20 was limited. Hepcidin-25 determination in real serum samples spiked with known analyte concentrations was also attempted. The integration of MIP NP to SPR allowed the determination of Hepcidin-25 at picomolar concentrations in short times outperforming the actual state of art. Optimization is still needed for real sample measurements in view of future clinical applications.
- 27 August 2015
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 13 (1) , 1-15
Open AccessSurface plasmon resonance based on molecularly imprinted nanoparticles for the picomolar detection of the iron regulating hormone Hepcidin-25
Molecularly imprinted polymer (MIP) technique is a powerful mean to produce tailor made synthetic recognition sites. Here precipitation polymerization was exploited to produce a library of MIP nanoparticles (NPs) targeting the N terminus of the hormone Hepcidin-25, whose serum levels correlate with iron dis-metabolisms and doping. Biotinylated MIP NPs were immobilized to NeutrAvidin™ SPR sensor chip. The response of the MIP NP sensor to Hepcidin-25 was studied. Morphological analysis showed MIP NPs of 20–50 nm; MIP NP exhibited high affinity and selectivity for the target analyte: low nanomolar Kds for the interaction NP/Hepcidin-25, but none for the NP/non regulative Hepcidin-20. The MIP NP were integrated as recognition element in SPR allowing the detection of Hepcidin-25 in 3 min. Linearity was observed with the logarithm of Hepcidin-25 concentration in the range 7.2–720 pM. LOD was 5 pM. The response for Hepcidin-20 was limited. Hepcidin-25 determination in real serum samples spiked with known analyte concentrations was also attempted. The integration of MIP NP to SPR allowed the determination of Hepcidin-25 at picomolar concentrations in short times outperforming the actual state of art. Optimization is still needed for real sample measurements in view of future clinical applications.
- 2 May 2014
- Published by Wiley in Surface and Interface Analysis
- Vol. 46 (10-11) , 927-930
Quality management system and accreditation of measurements in a surface science laboratory: the case study of MiNALab
With the continuously increasing demand for traceable and often accredited measurements in the scientific community, the quality management of laboratory activity according to international ISO standards can be a valuable and proficient solution. In this paper, we describe a decade of work in this direction. The implementation of quality management according to the ISO/IEC 17025 ‘ General requirements for the competence of testing and calibration laboratories ’ in a surface science research‐oriented analytical laboratory is presented. We analyze difficulties and drawbacks as well as benefits and permanent improvements that followed the accreditation, its maintenance, and extension to new methods. Copyright © 2014 John Wiley & Sons, Ltd.
- 2 May 2014
- Published by Wiley in Surface and Interface Analysis
- Vol. 46 (10-11) , 927-930
Quality management system and accreditation of measurements in a surface science laboratory: the case study of MiNALab
With the continuously increasing demand for traceable and often accredited measurements in the scientific community, the quality management of laboratory activity according to international ISO standards can be a valuable and proficient solution. In this paper, we describe a decade of work in this direction. The implementation of quality management according to the ISO/IEC 17025 ‘ General requirements for the competence of testing and calibration laboratories ’ in a surface science research‐oriented analytical laboratory is presented. We analyze difficulties and drawbacks as well as benefits and permanent improvements that followed the accreditation, its maintenance, and extension to new methods. Copyright © 2014 John Wiley & Sons, Ltd.
- 18 April 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 409-412
Development of nano‐roughness under SIMS ion sputtering of germanium surfaces
In this work results, about the formation of topography and roughness induced by secondary ion mass spectrometry ion beam sputtering of single crystal (100) germanium surfaces are reported and related with depth resolution issues and matrix species ( 74 Ge ± ; 74 Ge 16 O ± ; 74 Ge 2 ± ) behavior. In particular, the development of nano‐roughness is studied for both O 2 + and Cs + bombardment at low energy (≤ 3 keV), using a magnetic sector instrument. Analysis was carried out in the sputtering chamber either at ultra‐high vacuum (~10 −9 mbar) or at a reduced pressure (~10 −6 mbar) by oxygen leak. Zalar rotation was also tested as a method to reduce the formation of topography where observed. The results show that ripples are formed under O 2 + sputtering for energies ≤ 1 keV (incidence angle ~60°) without rotation, although their amplitude is very small compared to the crater depth. No relevant roughness is observed in the craters when Cs + ions are used (inc. angle ~50°), while particles of aggregated Cs are detected. Copyright © 2012 John Wiley & Sons, Ltd.
- 18 April 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 409-412
Development of nano‐roughness under SIMS ion sputtering of germanium surfaces
In this work results, about the formation of topography and roughness induced by secondary ion mass spectrometry ion beam sputtering of single crystal (100) germanium surfaces are reported and related with depth resolution issues and matrix species ( 74 Ge ± ; 74 Ge 16 O ± ; 74 Ge 2 ± ) behavior. In particular, the development of nano‐roughness is studied for both O 2 + and Cs + bombardment at low energy (≤ 3 keV), using a magnetic sector instrument. Analysis was carried out in the sputtering chamber either at ultra‐high vacuum (~10 −9 mbar) or at a reduced pressure (~10 −6 mbar) by oxygen leak. Zalar rotation was also tested as a method to reduce the formation of topography where observed. The results show that ripples are formed under O 2 + sputtering for energies ≤ 1 keV (incidence angle ~60°) without rotation, although their amplitude is very small compared to the crater depth. No relevant roughness is observed in the craters when Cs + ions are used (inc. angle ~50°), while particles of aggregated Cs are detected. Copyright © 2012 John Wiley & Sons, Ltd.