Horacio T. Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Horacio T. Sánchez has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Estrems
Universidad Politécnica de Cartagena
7 shared publications F. Faura
ETS Ingeniería Industrial- Universidad Politécnica de Cartagena
4 shared publicationsFélix Faura
Department of Materials and Manufacturing Engineering, Polytechnical University of Cartagena, Cartagena, Spain
1 shared publication- Julio Carrero-Blanco
Universidad Politécnica de Cartagena: Universidad Politecnica de Cartagena
1 shared publication P. Sánchez
ETS Ingeniería Industrial–Universidad Politécnica de Cartagena
1 shared publication- Óscar de Francisco Ortiz
Technical University of Cartagena
1 shared publication
Latest Publications
- Open Access
Enhanced Positioning Algorithm Using a Single Image in an LCD-Camera System by Mesh Elements’ Recalculation and Angle Error Orientation
In this article, we present a method to position the tool in a micromachine system based on a camera-LCD screen positioning system that also provides information about angular deviations of the tool axis during its running. Both position and angular deviations are obtained by reducing a matrix of LEDs in the image to a single rectangle in the conical perspective that is treated by a photogrammetry method. This method computes the coordinates and orientation of the camera with respect to the fixed screen coordinate system. The used image consists of 5 × 5 lit LEDs, which are analyzed by the algorithm to determine a rectangle with known dimensions. The coordinates of the vertices of the rectangle in space are obtained by an inverse perspective computation from the image. The method presents a good approximation of the central point of the rectangle and provides the inclination of the workpiece with respect to the LCD screen reference system of coordinates. A test of the method is designed with the assistance of a Coordinate Measurement Machine (CMM) to check the accuracy of the positioning method. The performed test delivers a good accuracy in the position measurement of the designed method. A high dispersion in the angular deviation is detected, although the orientation of the inclination is appropriate in almost every case. This is due to the small values of the angles that makes the trigonometric function approximations very erratic. This method is a good starting point for the compensation of angular deviation in vision based micromachine tools, which is the principal source of errors in these operations and represents the main volume in the cost of machine elements’ parts.
Open AccessEnhanced Positioning Algorithm Using a Single Image in an LCD-Camera System by Mesh Elements’ Recalculation and Angle Error Orientation
In this article, we present a method to position the tool in a micromachine system based on a camera-LCD screen positioning system that also provides information about angular deviations of the tool axis during its running. Both position and angular deviations are obtained by reducing a matrix of LEDs in the image to a single rectangle in the conical perspective that is treated by a photogrammetry method. This method computes the coordinates and orientation of the camera with respect to the fixed screen coordinate system. The used image consists of 5 × 5 lit LEDs, which are analyzed by the algorithm to determine a rectangle with known dimensions. The coordinates of the vertices of the rectangle in space are obtained by an inverse perspective computation from the image. The method presents a good approximation of the central point of the rectangle and provides the inclination of the workpiece with respect to the LCD screen reference system of coordinates. A test of the method is designed with the assistance of a Coordinate Measurement Machine (CMM) to check the accuracy of the positioning method. The performed test delivers a good accuracy in the position measurement of the designed method. A high dispersion in the angular deviation is detected, although the orientation of the inclination is appropriate in almost every case. This is due to the small values of the angles that makes the trigonometric function approximations very erratic. This method is a good starting point for the compensation of angular deviation in vision based micromachine tools, which is the principal source of errors in these operations and represents the main volume in the cost of machine elements’ parts.
- 9 January 2008
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 40 (1-2) , 84-94
SCADA system improvement in PVC high frequency plastic welding
- 9 January 2008
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 40 (1-2) , 84-94
SCADA system improvement in PVC high frequency plastic welding
- 1 September 2006
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 29 (5-6) , 426-435
Fixturing analysis methods for calculating the contact load distribution and the valid clamping regions in machining processes
- 1 September 2006
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 29 (5-6) , 426-435
Fixturing analysis methods for calculating the contact load distribution and the valid clamping regions in machining processes
- 18 January 2006
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 29 (3-4) , 239-252
Analysis and compensation of positional and deformation errors using integrated fixturing analysis in flexible machining parts
- 18 January 2006
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 29 (3-4) , 239-252
Analysis and compensation of positional and deformation errors using integrated fixturing analysis in flexible machining parts