STShu Takagi

Shu Takagi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shu Takagi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery

    by Fuyou Liang, Kazuaki Fukasaku, Hao Liu, Shu Takagi

    Cerebral hyperperfusion syndrome develops in a small subset of patients following carotid artery surgery (CAS) performed to treat severe carotid artery stenosis. This syndrome has been found to have a close correlation with cerebral hyperperfusion occurring after CAS. The purpose of this study is to investigate whether and how the anatomy of the Circle of Willis (CoW) of the cerebral circulation influences post-CAS cerebral hyperperfusion. A computational model of the cerebral circulation coupled with the global cardiovascular system has been developed to investigate hemodynamic events associated with CAS. Nine topological structures of the CoW were investigated in combination with various distribution patterns of stenosis in the feeding arteries of the cerebral circulation. The occurrence of post-CAS cerebral hyperperfusion was predicted for the CoW structures that have poor collateral pathways between the stenosed cerebral feeding arteries and the remaining normal feeding arteries. The risk and the localization of post-CAS hyperperfusion were determined jointly by the anatomy of the CoW and the distribution pattern of stenosis in the cerebral feeding arteries. The presence of basilar artery stenosis or contralateral ICA stenosis increased the risk of post-CAS hyperperfusion and enlarged the cerebral region affected by hyperperfusion. For a certain CoW structure, the diameters of the cerebral communicating arteries and the severity of carotid artery stenosis both had a significant influence on the computed post-CAS cerebral hyperperfusion rates. Moreover, post-CAS cerebral hyperperfusion was predicted to be accompanied with an excessively high capillary transmural pressure. This study demonstrated the importance of considering the anatomy of the CoW in assessing the risk of post-CAS cerebral hyperperfusion. Particularly, since the anatomy of the CoW and the distribution pattern of stenosis in the cerebral feeding arteries jointly determine the risk and localization of post-CAS cerebral hyperperfusion, a patient-specific hemodynamic analysis aimed to help physicians identify patients at high risk of cerebral hyperperfusion should account for the combined effect of the anatomy of cerebral arteries and cerebral feeding artery stenoses on cerebral hemodynamics.


  • Full Eulerian simulations of biconcave neo-Hookean particles in a Poiseuille flow

    by Kazuyasu Sugiyama, Satoshi Ii, Shintaro Takeuchi, Shu Takagi, Yoichiro Matsumoto


  • The Deformation Behavior of Multiple Red Blood Cells in a Capillary Vessel

    by Xiaobo Gong, Kazuyasu Sugiyama, Shu Takagi, Yoichiro Matsumoto

    The deformation of multiple red blood cells in a capillary flow was studied numerically. The immersed boundary method was used for the fluid red blood cells interaction. The membrane of the red blood cell was modeled as a hyperelastic thin shell. The numerical results show that the apparent viscosity in the capillary flow is more sensitive to the change of shear coefficient of the membrane than the bending coefficient and surface dilation coefficient, and the increase in the shear coefficient results in an increase in the pressure drop in the blood flow in capillary vessels in order to sustain the same flux rate of red blood cells.


  • Multi-scale modeling of the human cardiovascular system with applications to aortic valvular and arterial stenoses

    by Fuyou Liang, Shu Takagi, Ryutaro Himeno, Hao Liu

    A computational model of the entire cardiovascular system is established based on multi-scale modeling, where the arterial tree is described by a one-dimensional model coupled with a lumped parameter description of the remainder. The resultant multi-scale model forms a closed loop, thus placing arterial wave propagation into a global hemodynamic environment. The model is applied to study the global hemodynamic influences of aortic valvular and arterial stenoses located in various regions. Obtained results show that the global hemodynamic influences of the stenoses depend strongly on their locations in the arterial system, particularly, the characteristics of hemodynamic changes induced by the aortic valvular and aortic stenoses are pronounced, which imply the possibility of noninvasively detecting the presence of the stenoses from peripheral pressure pulses. The variations in aortic pressure/flow pulses with the stenoses play testimony to the significance of modeling the entire cardiovascular system in the study of arterial diseases.


  • The Deformation of a Vesicle in a Linear Shear Flow

    by Shu Takagi, Takeshi Yamada, Xiaobo Gong, Yoichiro Matsumoto

    In this paper, we discuss the motion of a vesicle in a linear shear flow. It is known that deformable vesicles such as liposomes show the so-called tank-treading and tumbling motions depending on the viscosity ratio between the inside and outside of the vesicle, the swelling ratio, and so on. First, we have conducted numerical simulations on the tank-treading motion of a liposome in a linear shear flow and compared the results with other numerical and experimental results. It is confirmed that the inclination angle of the vesicle becomes smaller when the viscosity ratio becomes larger or the swelling ratio becomes smaller and that the present results show quantitatively good agreement with other results. Then, the effects of membrane modeling are discussed from the mechanics point of view. There are two types of modeling for the lipid bilayer biomembrane. One is a two-dimensional fluid membrane, which reflects the fluidity of the lipid molecules. The other is a hyperelastic membrane, which reflects the stiffness of cytoskeleton structure. Liposome is usually modeled as a fluid membrane and red blood cell (RBC) is modeled as a hyperelastic one. We discuss how these differences of membrane models affect the behaviors of vesicles under the presence of shear flow. It is shown that the hyperelastic membrane model for RBC shows a less inclination angle of tank-treading motion and early transition from tank-treading to tumbling.