Yoichiro Matsumoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yoichiro Matsumoto has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Shu Takagi
The University of Tokyo
4 shared publications - Shu Takagi
RIKEN
3 shared publications - Kazuyasu Sugiyama
Osaka University
2 shared publications - Kohei Okita
College of Industrial Technology, Nihon University, Narashino, Chiba, Japan
2 shared publications - Ryuta Narumi
Department of Bioengineering, The University of Tokyo, Tokyo, Japan
2 shared publications - Shin Yoshizawa
Graduate School of Engineering, Tohoku University, Sendai, Japan
2 shared publications
Latest Publications
- Open Access
- 20 June 2018
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 6 (1) , 4
Effects of breast structure on high-intensity focused ultrasound focal error
The development of imaging technologies and breast cancer screening allowed early detection of breast cancers. High-intensity focused ultrasound (HIFU) is a non-invasive cancer treatment, but the success of HIFU ablation was depending on the system type, imaging technique, ablation protocol, and patient selection. Therefore, we aimed to determine the relationship between breast tissue structure and focal error during breast cancer HIFU treatment. Numerical simulations of the breast cancer HIFU ablation were performed using digital breast phantoms constructed using the magnetic resonance imaging data obtained from 12 patients. The focal shapes were distorted despite breast tissue representing soft tissue. Focal errors are caused by the complex distribution of fibroglandular tissue, and they depend on the target position and the arrangement of the transducer. We demonstrated that the focusing ratio increases with the decrease in the local acoustic inhomogeneity, implying that it may be used as an indicator to reduce the HIFU focal error depending on the breast structure. The obtained results demonstrated that the focal error observed during the breast cancer HIFU treatment is highly dependent on the structure of fibroglandular tissue. The optimal arrangement of the transducer to the target can be obtained by minimizing the local acoustic inhomogeneity before the breast cancer HIFU treatment.
- 20 June 2018
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 6 (1) , 4
Open AccessEffects of breast structure on high-intensity focused ultrasound focal error
The development of imaging technologies and breast cancer screening allowed early detection of breast cancers. High-intensity focused ultrasound (HIFU) is a non-invasive cancer treatment, but the success of HIFU ablation was depending on the system type, imaging technique, ablation protocol, and patient selection. Therefore, we aimed to determine the relationship between breast tissue structure and focal error during breast cancer HIFU treatment. Numerical simulations of the breast cancer HIFU ablation were performed using digital breast phantoms constructed using the magnetic resonance imaging data obtained from 12 patients. The focal shapes were distorted despite breast tissue representing soft tissue. Focal errors are caused by the complex distribution of fibroglandular tissue, and they depend on the target position and the arrangement of the transducer. We demonstrated that the focusing ratio increases with the decrease in the local acoustic inhomogeneity, implying that it may be used as an indicator to reduce the HIFU focal error depending on the breast structure. The obtained results demonstrated that the focal error observed during the breast cancer HIFU treatment is highly dependent on the structure of fibroglandular tissue. The optimal arrangement of the transducer to the target can be obtained by minimizing the local acoustic inhomogeneity before the breast cancer HIFU treatment.
- 8 May 2014
- Published by Springer Nature in Computational Mechanics
- Vol. 54 (4) , 1023-1033
The role of numerical simulation for the development of an advanced HIFU system
- 8 May 2014
- Published by Springer Nature in Computational Mechanics
- Vol. 54 (4) , 1023-1033
The role of numerical simulation for the development of an advanced HIFU system
- 23 May 2012
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 28 (4) , 290-299
Ultrasound-mediated gene transfection in vitro: Effect of ultrasonic parameters on efficiency and cell viability
Ultrasound (US)-mediated gene transfection in the presence of microbubbles is a recently developed and promising non-viral gene delivery method. Optimising the parameters used in ultrasonic transfection is urgently required in order to realise higher transfection efficiencies in clinical settings. This study examined the effect of ultrasound exposure parameters on plasmid DNA transfection in mouse embryonic fibroblast cell lines using perfluorobutane bubbles. Variations in US intensity (0–11 W/cm2), pulse repetition frequency (PRF, 50–50,000 Hz), duty ratio (10 to 50%), exposure time (0–120 s) and microbubble volume concentration (0 to 10%) were tested, and the microbubble volume concentration was also monitored during exposure. Through the experiments, the mechanism of how variations in parameters influence US-mediated gene transfection was discussed, which can provide a basis for future applications of ultrasound mediated transfection.
- 23 May 2012
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 28 (4) , 290-299
Ultrasound-mediated gene transfection in vitro: Effect of ultrasonic parameters on efficiency and cell viability
Ultrasound (US)-mediated gene transfection in the presence of microbubbles is a recently developed and promising non-viral gene delivery method. Optimising the parameters used in ultrasonic transfection is urgently required in order to realise higher transfection efficiencies in clinical settings. This study examined the effect of ultrasound exposure parameters on plasmid DNA transfection in mouse embryonic fibroblast cell lines using perfluorobutane bubbles. Variations in US intensity (0–11 W/cm2), pulse repetition frequency (PRF, 50–50,000 Hz), duty ratio (10 to 50%), exposure time (0–120 s) and microbubble volume concentration (0 to 10%) were tested, and the microbubble volume concentration was also monitored during exposure. Through the experiments, the mechanism of how variations in parameters influence US-mediated gene transfection was discussed, which can provide a basis for future applications of ultrasound mediated transfection.
- 10 March 2010
- Published by Springer Nature in Computational Mechanics
- Vol. 46 (1) , 147-157
Full Eulerian simulations of biconcave neo-Hookean particles in a Poiseuille flow
- 10 March 2010
- Published by Springer Nature in Computational Mechanics
- Vol. 46 (1) , 147-157
Full Eulerian simulations of biconcave neo-Hookean particles in a Poiseuille flow
- 4 June 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (7) , 074504
The Deformation Behavior of Multiple Red Blood Cells in a Capillary Vessel
The deformation of multiple red blood cells in a capillary flow was studied numerically. The immersed boundary method was used for the fluid red blood cells interaction. The membrane of the red blood cell was modeled as a hyperelastic thin shell. The numerical results show that the apparent viscosity in the capillary flow is more sensitive to the change of shear coefficient of the membrane than the bending coefficient and surface dilation coefficient, and the increase in the shear coefficient results in an increase in the pressure drop in the blood flow in capillary vessels in order to sustain the same flux rate of red blood cells.
- 4 June 2009
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (7) , 074504
The Deformation Behavior of Multiple Red Blood Cells in a Capillary Vessel
The deformation of multiple red blood cells in a capillary flow was studied numerically. The immersed boundary method was used for the fluid red blood cells interaction. The membrane of the red blood cell was modeled as a hyperelastic thin shell. The numerical results show that the apparent viscosity in the capillary flow is more sensitive to the change of shear coefficient of the membrane than the bending coefficient and surface dilation coefficient, and the increase in the shear coefficient results in an increase in the pressure drop in the blood flow in capillary vessels in order to sustain the same flux rate of red blood cells.
- 10 April 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 47 (8) , 851-860
High intensity focused ultrasound lithotripsy with cavitating microbubbles
In the medical ultrasound field, microbubbles have recently been the subject of much interest. Controlling actively the effect of the microbubbles, a novel therapeutic method has been investigated. In this paper, our works on high intensity focused ultrasound (HIFU) lithotripsy with cavitating microbubbles are reviewed and the cavitation detection method to optimize the HIFU intensity is investigated. In the HIFU lithotripsy, collapse of the cloud cavitation is used to fragment kidney stones. Cloud cavitation is potentially the most destructive form of cavitation. When the cloud cavitation is acoustically forced into a collapse, it has the potential to concentrate a very high pressure. For the control of the cloud cavitation collapse, a novel two-frequency wave (cavitation control [C-C] waveform) is designed; a high-frequency ultrasound pulse (1–4 MHz) to create the cloud cavitation and a low-frequency trailing pulse (500 kHz) following the high-frequency pulse to force the cloud into collapse. High-speed photography showed the cavitation collapse on the stone and the shock-wave emission from the cloud. In vitro erosion tests of model and natural stones were also conducted. In the case of model stones, the erosion rate of the C-C waveform showed a distinct advantage with the combined high- and low-frequency waves over either wave alone. For the optimization of the high-frequency ultrasound intensity, the subharmonic acoustic pressure was examined. The results showed relationship between the subharmonic pressure from cavitating bubbles induced by the high-frequency ultrasound and eroded volume of the model stones. Natural stones were eroded and most of the resulting fragments were less than 1 mm in diameter. The method has the potential to provide a novel lithotripsy system with small fragments and localized cavitating bubbles on a stone.
- 10 April 2009
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 47 (8) , 851-860
High intensity focused ultrasound lithotripsy with cavitating microbubbles
In the medical ultrasound field, microbubbles have recently been the subject of much interest. Controlling actively the effect of the microbubbles, a novel therapeutic method has been investigated. In this paper, our works on high intensity focused ultrasound (HIFU) lithotripsy with cavitating microbubbles are reviewed and the cavitation detection method to optimize the HIFU intensity is investigated. In the HIFU lithotripsy, collapse of the cloud cavitation is used to fragment kidney stones. Cloud cavitation is potentially the most destructive form of cavitation. When the cloud cavitation is acoustically forced into a collapse, it has the potential to concentrate a very high pressure. For the control of the cloud cavitation collapse, a novel two-frequency wave (cavitation control [C-C] waveform) is designed; a high-frequency ultrasound pulse (1–4 MHz) to create the cloud cavitation and a low-frequency trailing pulse (500 kHz) following the high-frequency pulse to force the cloud into collapse. High-speed photography showed the cavitation collapse on the stone and the shock-wave emission from the cloud. In vitro erosion tests of model and natural stones were also conducted. In the case of model stones, the erosion rate of the C-C waveform showed a distinct advantage with the combined high- and low-frequency waves over either wave alone. For the optimization of the high-frequency ultrasound intensity, the subharmonic acoustic pressure was examined. The results showed relationship between the subharmonic pressure from cavitating bubbles induced by the high-frequency ultrasound and eroded volume of the model stones. Natural stones were eroded and most of the resulting fragments were less than 1 mm in diameter. The method has the potential to provide a novel lithotripsy system with small fragments and localized cavitating bubbles on a stone.
- 15 January 2009
- Published by Wiley in Journal of Applied Mechanics
- Vol. 76 (2) , 021207
The Deformation of a Vesicle in a Linear Shear Flow
In this paper, we discuss the motion of a vesicle in a linear shear flow. It is known that deformable vesicles such as liposomes show the so-called tank-treading and tumbling motions depending on the viscosity ratio between the inside and outside of the vesicle, the swelling ratio, and so on. First, we have conducted numerical simulations on the tank-treading motion of a liposome in a linear shear flow and compared the results with other numerical and experimental results. It is confirmed that the inclination angle of the vesicle becomes smaller when the viscosity ratio becomes larger or the swelling ratio becomes smaller and that the present results show quantitatively good agreement with other results. Then, the effects of membrane modeling are discussed from the mechanics point of view. There are two types of modeling for the lipid bilayer biomembrane. One is a two-dimensional fluid membrane, which reflects the fluidity of the lipid molecules. The other is a hyperelastic membrane, which reflects the stiffness of cytoskeleton structure. Liposome is usually modeled as a fluid membrane and red blood cell (RBC) is modeled as a hyperelastic one. We discuss how these differences of membrane models affect the behaviors of vesicles under the presence of shear flow. It is shown that the hyperelastic membrane model for RBC shows a less inclination angle of tank-treading motion and early transition from tank-treading to tumbling.
- 15 January 2009
- Published by Wiley in Journal of Applied Mechanics
- Vol. 76 (2) , 021207
The Deformation of a Vesicle in a Linear Shear Flow
In this paper, we discuss the motion of a vesicle in a linear shear flow. It is known that deformable vesicles such as liposomes show the so-called tank-treading and tumbling motions depending on the viscosity ratio between the inside and outside of the vesicle, the swelling ratio, and so on. First, we have conducted numerical simulations on the tank-treading motion of a liposome in a linear shear flow and compared the results with other numerical and experimental results. It is confirmed that the inclination angle of the vesicle becomes smaller when the viscosity ratio becomes larger or the swelling ratio becomes smaller and that the present results show quantitatively good agreement with other results. Then, the effects of membrane modeling are discussed from the mechanics point of view. There are two types of modeling for the lipid bilayer biomembrane. One is a two-dimensional fluid membrane, which reflects the fluidity of the lipid molecules. The other is a hyperelastic membrane, which reflects the stiffness of cytoskeleton structure. Liposome is usually modeled as a fluid membrane and red blood cell (RBC) is modeled as a hyperelastic one. We discuss how these differences of membrane models affect the behaviors of vesicles under the presence of shear flow. It is shown that the hyperelastic membrane model for RBC shows a less inclination angle of tank-treading motion and early transition from tank-treading to tumbling.
- 26 January 2007
- Published by Springer Nature
- p. 131-140
A Novel Definition of the Local and Instantaneous Liquid-Vapor Interface
- 26 January 2007
- Published by Springer Nature
- p. 131-140
A Novel Definition of the Local and Instantaneous Liquid-Vapor Interface
- 14 December 2004
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 47 (6-7) , 591-601
Behaviour of a bubble cluster in an ultrasound field
Ultrasound medical applications, such as an ultrasound imaging with micro‐bubble contrast agents, and high intensity focused ultrasound (HIFU) therapy have attracted much attention in recent years. These applications have a close relation to the motion of micro‐bubbles, so that it is essential to understand their dynamics. The bubble motion is influenced by the internal phenomena and its interaction with the surrounding medium, such as the thermal diffusion, the mist formation, the mass diffusion, the heat and mass transfer through the bubble wall. It is important that the oscillation of micro bubbles generates a strong acoustic pressure for these medical applications. The strong pressure also appears in the case of a bubble cluster, like a cloud cavitation. As these dynamics of bubbles are strongly influenced by the thermal phenomena inside them, it is necessary to construct the model taking these phenomena into account to analyse the behaviour of the bubble cluster precisely. Thus, the following effects are considered: the evaporation and condensation of the liquid at the bubble wall, the heat transfer through the bubble wall, and the compressibility of the liquid. Then the spherical bubble cluster is numerically simulated. When the frequency of the ultrasound is sufficiently high, the bubble cluster hardly oscillates. On the contrary, when the frequency of the ultrasound is at the resonance of the bubble cluster, the pressure wave generates the shock wave and it focuses to the cluster centre. As a result, the pressure inside the bubble at the cluster centre becomes much higher than that of a single bubble. Though this extreme high pressure causes the severe cavitation erosion, it is thought that this high energy concentration has the potential to be utilized for medical applications. Copyright © 2004 John Wiley & Sons, Ltd.
- 14 December 2004
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 47 (6-7) , 591-601
Behaviour of a bubble cluster in an ultrasound field
Ultrasound medical applications, such as an ultrasound imaging with micro‐bubble contrast agents, and high intensity focused ultrasound (HIFU) therapy have attracted much attention in recent years. These applications have a close relation to the motion of micro‐bubbles, so that it is essential to understand their dynamics. The bubble motion is influenced by the internal phenomena and its interaction with the surrounding medium, such as the thermal diffusion, the mist formation, the mass diffusion, the heat and mass transfer through the bubble wall. It is important that the oscillation of micro bubbles generates a strong acoustic pressure for these medical applications. The strong pressure also appears in the case of a bubble cluster, like a cloud cavitation. As these dynamics of bubbles are strongly influenced by the thermal phenomena inside them, it is necessary to construct the model taking these phenomena into account to analyse the behaviour of the bubble cluster precisely. Thus, the following effects are considered: the evaporation and condensation of the liquid at the bubble wall, the heat transfer through the bubble wall, and the compressibility of the liquid. Then the spherical bubble cluster is numerically simulated. When the frequency of the ultrasound is sufficiently high, the bubble cluster hardly oscillates. On the contrary, when the frequency of the ultrasound is at the resonance of the bubble cluster, the pressure wave generates the shock wave and it focuses to the cluster centre. As a result, the pressure inside the bubble at the cluster centre becomes much higher than that of a single bubble. Though this extreme high pressure causes the severe cavitation erosion, it is thought that this high energy concentration has the potential to be utilized for medical applications. Copyright © 2004 John Wiley & Sons, Ltd.