Yves Zerega
Yves Zerega has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
A. Janulyte
Université Aix-Marseille I, II et III
2 shared publicationsC. Reynard
Université Aix-Marseille I, II et III
2 shared publicationsA. Simon-Masseron
Université de Haute-Alsace
1 shared publication- Aurika Janulyte
Aix Marseille Universite
1 shared publication Christelle Reynard
Université de Provence, Laboratoire Chimie Provence - UMR CNRS 6264, Equipe Instrumentation et Réactivité Atmosphérique, Centre de Saint Jérôme Avenue Escadrille-Normandie-Niemen, 13397 Marseille, Cedex 20, France
1 shared publicationJ. Andre
Université de Provence, Laboratoire Chimie Provence – UMR CNRS 6264, Equipe Instrumentation et Réactivité Atmosphérique, Centre de Saint Jérôme, Avenue Escadrille-Normandie-Niemen, 13397 Marseille Cedex 20, France
1 shared publication
Latest Publications
- 24 March 2011
- Published by Springer Nature in Adsorption
- Vol. 17 (4) , 747-758
Selective adsorption of 2,3-DCDD and 1,2,3,4-TCDD on *BEA, EMT, FAU and MFI-type zeolites as alternative adsorbents for on-line dioxin monitoring
- 24 March 2011
- Published by Springer Nature in Adsorption
- Vol. 17 (4) , 747-758
Selective adsorption of 2,3-DCDD and 1,2,3,4-TCDD on *BEA, EMT, FAU and MFI-type zeolites as alternative adsorbents for on-line dioxin monitoring
- 21 January 2011
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 46 (2) , 136-143
Sensitivity and amplitude calibration of a Fourier transform 3D quadrupole ion trap mass spectrometer
- 21 January 2011
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 46 (2) , 136-143
Sensitivity and amplitude calibration of a Fourier transform 3D quadrupole ion trap mass spectrometer
- 17 July 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (16) , 2479-2492
Model for ion injection into a quadrupole ion trap to assess the distribution of initial conditions of confinement
A pulsed ion‐injection mode for a quadrupole ion trap is described. Switched direct current (d.c.) potentials are applied to the source and trap electrodes to inject the ions into the trap and slow them down. The injection time is sufficient to ensure a steady distribution of the injected ions at the beginning of the confinement. An elementary uni‐dimensional model is detailed giving the axial positions and velocities of the ions injected into the trap. The ion distribution in phase space, the number of injected ions and the number of injected ions that will be trapped are also given. These expressions depend on ion position and velocity at the creation, applied potentials and spatial location of the source and trap electrodes. This model is validated by comparing simulation and experimental results. For this purpose the number of confined ions is plotted versus the slowing‐down potentials applied on the ring and the upper end‐cap of the trap. The size of the area of removable ions in the source is deduced from these results. Copyright © 2008 John Wiley & Sons, Ltd.
- 17 July 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (16) , 2479-2492
Model for ion injection into a quadrupole ion trap to assess the distribution of initial conditions of confinement
A pulsed ion‐injection mode for a quadrupole ion trap is described. Switched direct current (d.c.) potentials are applied to the source and trap electrodes to inject the ions into the trap and slow them down. The injection time is sufficient to ensure a steady distribution of the injected ions at the beginning of the confinement. An elementary uni‐dimensional model is detailed giving the axial positions and velocities of the ions injected into the trap. The ion distribution in phase space, the number of injected ions and the number of injected ions that will be trapped are also given. These expressions depend on ion position and velocity at the creation, applied potentials and spatial location of the source and trap electrodes. This model is validated by comparing simulation and experimental results. For this purpose the number of confined ions is plotted versus the slowing‐down potentials applied on the ring and the upper end‐cap of the trap. The size of the area of removable ions in the source is deduced from these results. Copyright © 2008 John Wiley & Sons, Ltd.