TTTomoyuki Takeguchi

Tomoyuki Takeguchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tomoyuki Takeguchi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep Shrinkage Convolutional Neural Network for Adaptive Noise Reduction

    by Kenzo Isogawa, Takashi Ida, Taichiro Shiodera, Tomoyuki Takeguchi

    The noise level of an image depends on settings of an imaging device. The settings can be used to select appropriate parameters for denoising methods. But denoising methods based on deep convolutional neural networks (deep-CNNs) do not have such adjustable parameters. Therefore, a deep-CNN whose training data contain limited levels of noise does not effectively restore images whose noise level is different from the training data. If the range of noise levels of training data is extended to solve the problem, the maximum performance of a produced deep-CNN is limited. To solve the trade-off, we propose a deep-CNN that is adjustable to the noise level of the input image immediately. We use soft shrinkage for activation functions of our deep-CNN. The soft shrinkage has thresholds proportional to the noise level given by the user. We also propose an optimization method for proportionality coefficients for the thresholds of soft shrinkage. Our method optimizes the coefficients for various noise levels simultaneously. In our experiment using a test set whose noise level is from 5 to 50, the proposed method showed higher PSNR than that in the case of the conventional method using only one deep-CNN, and PSNR comparable to that in the case of the conventional method using multiple noise-level-specific CNNs.


  • Open Access

    Automatic slice-alignment method in cardiac magnetic resonance imaging for evaluation of the right ventricle in patients with pulmonary hypertension

    by Kenichi Yokoyama, Shuhei Nitta, Shigehide Kuhara, Rieko Ishimura, Toshiya Kariyasu, Masamichi Imai, Toshiaki Nitatori, Tomoyuki Takeguchi, Taichiro Shiodera

    We propose a new automatic slice-alignment method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, to simplify right ventricular cardiac scan planning and assess its accuracy and the clinical acceptability of the acquired imaging planes in the evaluation of patients with pulmonary hypertension. Steady-state free precession (SSFP) sequences covering the whole heart in the end-diastolic phase with ECG gating were used to acquire 2D axial multislice images. To realize right ventricular scan planning, two morphological feature points are added to be detected and a total of eight morphological features of the heart were extracted from these series of images, and six left ventricular planes and four right ventricular planes were calculated simultaneously based on the extracted features. The subjects were 33 patients (25 with chronic thromboembolic pulmonary hypertension and 8 with idiopathic pulmonary arterial hypertension). The four right ventricular reference planes including right ventricular short-axis, 4-chamber, 2-chamber, and 3-chamber images were evaluated. The acceptability of the acquired imaging planes was visually evaluated using a 4-point scale, and the angular differences between the results obtained by this method and by conventional manual annotation were measured for each view. The average visual scores were 3.9±0.4 for short-axis images, 3.8±0.4 for 4-chamber images, 3.8±0.4 for 2-chamber images, and 3.5±0.6 for 3-chamber images. The average angular differences were 8.7±5.3, 8.3±4.9, 8.1±4.8, and 7.9±5.3 degrees, respectively. The processing time was less than 2.5 seconds in all subjects. The proposed method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, can provide clinically acceptable planes in a short time and is useful because special proficiency in performing cardiac MR for patients with right ventricles of various sizes and shapes is not required.


  • Practical considerations for a method of rapid cardiac function analysis based on three-dimensional speckle tracking in a three-dimensional diagnostic ultrasound system

    by Tomoyuki Takeguchi, Masahide Nishiura, Yasuhiko Abe, Hiroyuki Ohuchi, Tetsuya Kawagishi

    The purpose of this study was to validate the accuracy of our novel 3D speckle tracking method by using numerical data, and to demonstrate the rapid processing of this method by using data obtained from human subjects. In order to create a method that can rapidly assess cardiac function in regional heart wall segments, a 3D speckle tracking algorithm was created that focuses on data quality and performance. Prototype application software based on this algorithm was written to evaluate cardiac wall motion and to calculate indices such as strain. Time series 3D image data were generated for artificial numerical models that simulate the shape of the left ventricle and exhibit various types of motion. We compared observed values returned by the algorithm with expected values yielded by the models. This software was also applied to volume data of the human heart acquired by a 3D ultrasound system. Measurement of the indices was evaluated by using an error ratio that was a residual between an expected value and estimated one divided by the expected value. The average error ratio of the time series volumes was less than 5% for all indices, and no individual error ratio was more than 10% for numerical models. The process was complete within 0.5 s per frame for human heart volumes. This application software can provide good estimates of various wall motion indices. The results are similar to data from numerical models, and are provided quickly enough for routine clinical usage.