Sébastien Krut
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sébastien Krut has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- François Pierrot
UMR 5506 CNRS/University of Montpellier
7 shared publications - Olivier Company
LIRMM, Montpellier, France
6 shared publications - Claude Durand
B+ Development, 1 traverse de la Penne, 13821 La Penne sur Huveaune FRANCE
2 shared publications - Etienne Dombre
LIRMM, UMR 5506, CNRS-Université Montpellier 2, Montpellier Cedex 05, France
2 shared publications Ch. Azevedo Coste
DEMAR INRIA/LIRMM, Montpellier Cedex 5, France
1 shared publication- Cédric Baradat
Fatronik Tecnalia
1 shared publication
Latest Publications
- 20 May 2014
- Published by Springer Nature
- p. 545-553
Dynamic Analysis of 4 Degrees of Freedom Redundant Parallel Manipulator
- 20 May 2014
- Published by Springer Nature
- p. 545-553
Dynamic Analysis of 4 Degrees of Freedom Redundant Parallel Manipulator
- Open Access
- 8 February 2011
- Published by Copernicus GmbH in Mechanical Sciences
- Vol. 2 (1) , 1-8
A simple design rule for 1st order form-closure of underactuated hands
The property of form-closure of a grasp, as generally defined in the literature, is based on the assumption that contact points between the hand and the object are fixed in space. However, this assumption is false when considering a grasp exerted by an underactuated hand, since in this case, it is not possible to control the position of each phalanx independently. In spite of researchers' interest in studying form-closure, none of the available published work on this subject takes into consideration the particular kinematics of underactuated hands. Actually, there are few available tools to qualify or quantify the stability of a grasp exerted by an underactuated hand, thus the design of underactuated hands mostly results from an intuitive approach. This paper aims to reduce this gap. A classification of underactuated hands is proposed, based on the expression of contact forces. This highlights the influence of non-backdrivable mechanisms introduced in the transmission of the closing motion of the hand on the stability of the grasp. The way to extend the original definition of form-closure to underactuated grasps is illustrated. A more general definition is formulated, which checks the stability of the set "object + hand". Using this new definition, a simple rule is proposed for designing a hand capable of achieving 1st order form-closed grasps. This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010), 19 August 2010, Montréal, Canada.
- 8 February 2011
- Published by Copernicus GmbH in Mechanical Sciences
- Vol. 2 (1) , 1-8
Open AccessA simple design rule for 1st order form-closure of underactuated hands
The property of form-closure of a grasp, as generally defined in the literature, is based on the assumption that contact points between the hand and the object are fixed in space. However, this assumption is false when considering a grasp exerted by an underactuated hand, since in this case, it is not possible to control the position of each phalanx independently. In spite of researchers' interest in studying form-closure, none of the available published work on this subject takes into consideration the particular kinematics of underactuated hands. Actually, there are few available tools to qualify or quantify the stability of a grasp exerted by an underactuated hand, thus the design of underactuated hands mostly results from an intuitive approach. This paper aims to reduce this gap. A classification of underactuated hands is proposed, based on the expression of contact forces. This highlights the influence of non-backdrivable mechanisms introduced in the transmission of the closing motion of the hand on the stability of the grasp. The way to extend the original definition of form-closure to underactuated grasps is illustrated. A more general definition is formulated, which checks the stability of the set "object + hand". Using this new definition, a simple rule is proposed for designing a hand capable of achieving 1st order form-closed grasps. This paper was presented at the IFToMM/ASME International Workshop on Underactuated Grasping (UG2010), 19 August 2010, Montréal, Canada.
- 6 January 2011
- Published by Springer Nature in Meccanica
- Vol. 46 (1) , 239-248
Par2: a spatial mechanism for fast planar two-degree-of-freedom pick-and-place applications
- 6 January 2011
- Published by Springer Nature in Meccanica
- Vol. 46 (1) , 239-248
Par2: a spatial mechanism for fast planar two-degree-of-freedom pick-and-place applications
- Open Access
- 1 January 2011
- Published by Hindawi Limited in Applied Bionics and Biomechanics
- Vol. 8 (3) , 385-398
Secure Microprocessor-Controlled Prosthetic Leg for Elderly Amputees: Preliminary Results
We introduce a new prosthetic leg design, adapted to elderly trans-femoral amputees. Technical progress in prosthesis design mainly concerns active individuals. An important number of elderly amputees are not very mobile, tire easily, present reduced muscle strength, and have difficulties managing their balance. Therefore, the needs and characteristics of this specific population are very different from those of younger ones and the prosthetic solutions are not adapted. Our artificial knee has been designed to fulfill the specific requirements of this population in terms of capabilities, transfer assistance, security, intuitiveness, simplicity of use, and types of physical activity to be performed. We particularly focused our efforts on ensuring safe and secure stand-to-sit transfers. We developed an approach to control the different states of the prosthetic joint (blocked, free, resistant), associated with different physical activities. Amputee posture and motion are observed through a single multi-axis force sensor embedded in the prosthesis. The patient behaves naturally, while the controller analyses his movements in order to detect his intention to sit down. The detection algorithm is based on a reference pattern, calibrated individually, to which the sensor data are compared, and submitted to a set of tests allowing the discrimination of the intention to sit down from other activities. Preliminary validation of the system has been performed in order to verify the applicability of the prosthesis to different tasks: walking, standing, sitting down, standing up, picking up an object from a chair, slope and stair climbing.
- 1 January 2011
- Published by Hindawi Limited in Applied Bionics and Biomechanics
- Vol. 8 (3) , 385-398
Open AccessSecure Microprocessor-Controlled Prosthetic Leg for Elderly Amputees: Preliminary Results
We introduce a new prosthetic leg design, adapted to elderly trans-femoral amputees. Technical progress in prosthesis design mainly concerns active individuals. An important number of elderly amputees are not very mobile, tire easily, present reduced muscle strength, and have difficulties managing their balance. Therefore, the needs and characteristics of this specific population are very different from those of younger ones and the prosthetic solutions are not adapted. Our artificial knee has been designed to fulfill the specific requirements of this population in terms of capabilities, transfer assistance, security, intuitiveness, simplicity of use, and types of physical activity to be performed. We particularly focused our efforts on ensuring safe and secure stand-to-sit transfers. We developed an approach to control the different states of the prosthetic joint (blocked, free, resistant), associated with different physical activities. Amputee posture and motion are observed through a single multi-axis force sensor embedded in the prosthesis. The patient behaves naturally, while the controller analyses his movements in order to detect his intention to sit down. The detection algorithm is based on a reference pattern, calibrated individually, to which the sensor data are compared, and submitted to a set of tests allowing the discrimination of the intention to sit down from other activities. Preliminary validation of the system has been performed in order to verify the applicability of the prosthesis to different tasks: walking, standing, sitting down, standing up, picking up an object from a chair, slope and stair climbing.
- 1 January 2008
- Published by Springer Nature
- p. 71-78
On the Design of Fully Constrained Parallel Cable-Driven Robots
- 1 January 2008
- Published by Springer Nature
- p. 71-78
On the Design of Fully Constrained Parallel Cable-Driven Robots
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 927-933
Mechanical design of a new pneumatically driven underactuated hand
This paper presents a new pneumatically driven underactuated hand with two fingers and 3 phalanxes per finger. Two evidences have led the design of this hand. Firstly, the use of pneumatic energy facilitates the underactuation of the hand, indeed a single T-connector suffices to share out one input among two outputs. Secondly, non-backdrivable mechanisms have to be used in the transmission of phalanx's motion so that the hand is capable of producing form-closed grasps. This latter design principle is justified using a newly developed method that permits to study the form-closure property of a grasp exerted by an underactuated hand. Moreover, the intriguing ejection phenomenon is avoided thanks to non-backdrivable mechanisms that prohibit any backward motion of phalanxes when correctly positioned. An original mechanism called the "pneumatic parallelogram" is described, it enables the hand to perform fine pinch grasps. Finally, the optimal design of both fingers is addressed with respect to the force-isotropy of the finger and the positiveness of phalanx forces
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 927-933
Mechanical design of a new pneumatically driven underactuated hand
This paper presents a new pneumatically driven underactuated hand with two fingers and 3 phalanxes per finger. Two evidences have led the design of this hand. Firstly, the use of pneumatic energy facilitates the underactuation of the hand, indeed a single T-connector suffices to share out one input among two outputs. Secondly, non-backdrivable mechanisms have to be used in the transmission of phalanx's motion so that the hand is capable of producing form-closed grasps. This latter design principle is justified using a newly developed method that permits to study the form-closure property of a grasp exerted by an underactuated hand. Moreover, the intriguing ejection phenomenon is avoided thanks to non-backdrivable mechanisms that prohibit any backward motion of phalanxes when correctly positioned. An original mechanism called the "pneumatic parallelogram" is described, it enables the hand to perform fine pinch grasps. Finally, the optimal design of both fingers is addressed with respect to the force-isotropy of the finger and the positiveness of phalanx forces
- 9 October 2006
- Published by Springer Nature
- p. 445-454
On PKM with articulated travelling-plate and large tilting angles
- 9 October 2006
- Published by Springer Nature
- p. 445-454
On PKM with articulated travelling-plate and large tilting angles
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21530858,p. 1656-1661
Heli4: A Parallel Robot for Scara Motions with a Very Compact Traveling Plate and a Symmetrical Design
This paper introduces Heli4 a new 4 degree-of-freedom parallel robot. It is inspired by the Delta architecture, but was designed to overcome its limitations, using an articulated traveling plate. Unlike most articulated traveling plates, Heli4's traveling plate is very compact. Among other positive aspects is its symmetrical design. This paper gives the geometrical models, and particularly the forward position relationship which can be obtained in a closed form. In a third part, a detailed study of the robot singularities is made by taking into account the not-so-classic internal singularities
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21530858,p. 1656-1661
Heli4: A Parallel Robot for Scara Motions with a Very Compact Traveling Plate and a Symmetrical Design
This paper introduces Heli4 a new 4 degree-of-freedom parallel robot. It is inspired by the Delta architecture, but was designed to overcome its limitations, using an articulated traveling plate. Unlike most articulated traveling plates, Heli4's traveling plate is very compact. Among other positive aspects is its symmetrical design. This paper gives the geometrical models, and particularly the forward position relationship which can be obtained in a closed form. In a third part, a detailed study of the robot singularities is made by taking into account the not-so-classic internal singularities
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
On the Form-Closure Capability of Robotic Underactuated Hands
This paper presents a new method to study the capability of an underactuated hand to produce form-closed grasps. First, the stability behaviours of different underactuated parallel-jaw grippers are analyzed and compared according to their actuation and transmission mechanisms. Then, both notions of 1st order and 2nd order form-closure are revisited for underactuated hands, since in this particular case the assumption of fixed contacts made in the original definition is false. Therefore, constraints imposed by non-backdrivable mechanisms are introduced into the model of the whole grasp. Finally, a simple geometrical condition, necessary and sufficient for 1st order form-closure is proposed. This permits to conclude on the minimum number of non-backdrivable mechanisms required to produce 1st order form-closed grasps using an underactuated hand
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
On the Form-Closure Capability of Robotic Underactuated Hands
This paper presents a new method to study the capability of an underactuated hand to produce form-closed grasps. First, the stability behaviours of different underactuated parallel-jaw grippers are analyzed and compared according to their actuation and transmission mechanisms. Then, both notions of 1st order and 2nd order form-closure are revisited for underactuated hands, since in this particular case the assumption of fixed contacts made in the original definition is false. Therefore, constraints imposed by non-backdrivable mechanisms are introduced into the model of the whole grasp. Finally, a simple geometrical condition, necessary and sufficient for 1st order form-closure is proposed. This permits to conclude on the minimum number of non-backdrivable mechanisms required to produce 1st order form-closed grasps using an underactuated hand
- 1 March 2004
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 22 (2) , 129-139
Velocity performance indices for parallel mechanisms with actuation redundancy
This paper analyses the concept of velocity isotropy for Parallel Mechanisms with Actuation Redundancy (PMAR). The limits of classical indices based on the Jacobean matrix condition number are shown. It is proposed to use either the largest ellipsoid included in the operational polytop, or the operational polytop itself, as better representations of a PMAR capabilities. The polytop is studied because it is actually the accurate representation of a machine capability, while the largest ellipsoid remains similar to the classical tool roboticists are dealing with for decades. Velocity performance indices are proposed, and the ways to compute them efficiently are given.
- 1 March 2004
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 22 (2) , 129-139
Velocity performance indices for parallel mechanisms with actuation redundancy
This paper analyses the concept of velocity isotropy for Parallel Mechanisms with Actuation Redundancy (PMAR). The limits of classical indices based on the Jacobean matrix condition number are shown. It is proposed to use either the largest ellipsoid included in the operational polytop, or the operational polytop itself, as better representations of a PMAR capabilities. The polytop is studied because it is actually the accurate representation of a machine capability, while the largest ellipsoid remains similar to the classical tool roboticists are dealing with for decades. Velocity performance indices are proposed, and the ways to compute them efficiently are given.