Hideki Ogura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hideki Ogura has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
M. Izuchi
National Institute of Advanced Industrial Science and Technology (NMIJ, AIST)
9 shared publicationsM. Arai
National Institute of Advanced Industrial Science and Technology (NMIJ, AIST)
7 shared publications- Ikuhiko Saito
National Institute of Advanced Industrial Science and Technology, National Metrology Institute of Japan, (AIST, NMIJ), Tsukuba, Ibaraki, Japan
4 shared publications - Jun Tamba
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ, AIST)
4 shared publications - Kazuaki Yamazawa
National Institute of Advanced Industrial Science and Technology (NMIJ, AIST)
4 shared publications H. Numajiri
3 shared publications
Latest Publications
- 1 July 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (7)
Thermodynamic Temperature Measurements from the Melting Point of Gallium Down to the Triple Point of Mercury
- 1 July 2024
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (7)
Thermodynamic Temperature Measurements from the Melting Point of Gallium Down to the Triple Point of Mercury
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 130007
The stability of chip-size thermistors for miniature atomic clocks
The AIST/NMIJ has been developing miniature atomic clocks to increase the availability of accurate time references. The behavior frequency of a miniature atomic The AIST/NMIJ has been developing miniature atomic clocks to increase the availability of accurate time references. The behavior frequency of a miniature atomic
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 130007
The stability of chip-size thermistors for miniature atomic clocks
The AIST/NMIJ has been developing miniature atomic clocks to increase the availability of accurate time references. The behavior frequency of a miniature atomic The AIST/NMIJ has been developing miniature atomic clocks to increase the availability of accurate time references. The behavior frequency of a miniature atomic
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 070003
Evaluation of the realization of Rh-C eutectic point for thermocouple calibration
The rhodium-carbon (Rh-C) eutectic point (1657 °C) is considered as one of the useful practical fixed points for the accurate calibration of thermocouples above The rhodium-carbon (Rh-C) eutectic point (1657 °C) is considered as one of the useful practical fixed points for the accurate calibration of thermocouples above
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 070003
Evaluation of the realization of Rh-C eutectic point for thermocouple calibration
The rhodium-carbon (Rh-C) eutectic point (1657 °C) is considered as one of the useful practical fixed points for the accurate calibration of thermocouples above The rhodium-carbon (Rh-C) eutectic point (1657 °C) is considered as one of the useful practical fixed points for the accurate calibration of thermocouples above
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 050011
Construction and evaluation of gallium point cells
One of the fixed points of the international temperature scale of 1990 (ITS-90) for calibrating a standard platinum resistance thermometer (SPRT) is the melting One of the fixed points of the international temperature scale of 1990 (ITS-90) for calibrating a standard platinum resistance thermometer (SPRT) is the melting
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 050011
Construction and evaluation of gallium point cells
One of the fixed points of the international temperature scale of 1990 (ITS-90) for calibrating a standard platinum resistance thermometer (SPRT) is the melting One of the fixed points of the international temperature scale of 1990 (ITS-90) for calibrating a standard platinum resistance thermometer (SPRT) is the melting
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 413-415
Progress in the development of thermocouple calibration at Rh-C eutectic point
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 413-415
Progress in the development of thermocouple calibration at Rh-C eutectic point
- 17 March 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (5) , 73
Design and Investigation of Pd–C Eutectic Fixed-Point Cells for Thermocouple Calibration at NMIA
- 17 March 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (5) , 73
Design and Investigation of Pd–C Eutectic Fixed-Point Cells for Thermocouple Calibration at NMIA
- 14 December 2016
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (2) , 27
Comparisons of Co–C and Pd–C Eutectic-Point Cells for Thermocouple Calibration Between NMIA and NMIJ
- 14 December 2016
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (2) , 27
Comparisons of Co–C and Pd–C Eutectic-Point Cells for Thermocouple Calibration Between NMIA and NMIJ
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 03003
Final report of APMP.T-S7: APMP regional comparison of Co-C eutectic melting point using Pt/Pd thermocouples
A regional supplementary comparison on the Co-C eutectic point (1324 °C in ITS-90) was carried out in APMP involving five NMIs: KRISS (Korea), NIM (China), NMIJ (Japan), NMIA (Australia) and NPLI (India). The comparison was done through a round robin style with two Pt/Pd thermocouples having greatly different thermoelectric inhomogeneity (± 0.0196 % and ± 0.132 % at 1324 °C), which were made by the pilot laboratory (KRISS). Both were calibrated twice, before and after the circulation by the pilot laboratory. As a reference value, the weighted mean was adopted since the Birge ration criterion was safely satisfied. The participants were asked to supply the temperature profile of the furnace used to realize the Co-C point in order to estimate the uncertainty due to thermoelectric inhomogeneity. Results from all laboratories were consistent with the reference value within the calculated uncertainties. Birge number of 0.2 to 0.3 and En number less than 0.5 were obtained, meaning that the comparison successfully demonstrated the use of Pt/Pd thermocouple to compare the calibration capabilities of participating laboratories at the melting temperature of Co-C eutectic point regardless of the amount of thermoelectric inhomogeneity. It was verified that the calibration uncertainty level of {(0.2 °C ~ 0.3 °C) + ucell} (k = 2) can be obtained at the Co-C eutectic melting point by means of Pt/Pd thermocouple having a small inhomogeneity of about 0.02 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 03003
Final report of APMP.T-S7: APMP regional comparison of Co-C eutectic melting point using Pt/Pd thermocouples
A regional supplementary comparison on the Co-C eutectic point (1324 °C in ITS-90) was carried out in APMP involving five NMIs: KRISS (Korea), NIM (China), NMIJ (Japan), NMIA (Australia) and NPLI (India). The comparison was done through a round robin style with two Pt/Pd thermocouples having greatly different thermoelectric inhomogeneity (± 0.0196 % and ± 0.132 % at 1324 °C), which were made by the pilot laboratory (KRISS). Both were calibrated twice, before and after the circulation by the pilot laboratory. As a reference value, the weighted mean was adopted since the Birge ration criterion was safely satisfied. The participants were asked to supply the temperature profile of the furnace used to realize the Co-C point in order to estimate the uncertainty due to thermoelectric inhomogeneity. Results from all laboratories were consistent with the reference value within the calculated uncertainties. Birge number of 0.2 to 0.3 and En number less than 0.5 were obtained, meaning that the comparison successfully demonstrated the use of Pt/Pd thermocouple to compare the calibration capabilities of participating laboratories at the melting temperature of Co-C eutectic point regardless of the amount of thermoelectric inhomogeneity. It was verified that the calibration uncertainty level of {(0.2 °C ~ 0.3 °C) + ucell} (k = 2) can be obtained at the Co-C eutectic melting point by means of Pt/Pd thermocouple having a small inhomogeneity of about 0.02 %. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 28 February 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 1888-1894
Development and Evaluation of a Co–C Eutectic-Point Cell for Thermocouple Calibration
- 28 February 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 1888-1894
Development and Evaluation of a Co–C Eutectic-Point Cell for Thermocouple Calibration
- 10 January 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (2-3) , 385-398
Realization of Ru–C Eutectic Point for Evaluation of W–Re and IrRh/Ir Thermocouples
- 10 January 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (2-3) , 385-398
Realization of Ru–C Eutectic Point for Evaluation of W–Re and IrRh/Ir Thermocouples