Jun Tamba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun Tamba has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Kazuaki Yamazawa
National Institute of Advanced Industrial Science and Technology (NMIJ, AIST)
17 shared publications M. Arai
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ, AIST)
12 shared publications- Januarius V. Widiatmo
National Metrology Institute of Japan, AIST, Tsukuba, Japan
10 shared publications M. Izuchi
National Institute of Advanced Industrial Science and Technology (NMIJ, AIST), Tsukuba, Ibaraki, Japan
5 shared publicationsMasaru Arai
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST) Tsukuba Central 3, Umezono 1-1-1, Tsukuba, Ibaraki 305-8563, Japan
5 shared publications- Hideki Ogura
National Institute of Advanced Industrial Science and Technology (NMIJ, AIST)
4 shared publications
Latest Publications
- 1 May 2019
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Spacecraft and Rockets
- Vol. 56 (3) , 771-779
Thermal Performance and Flow Visualization of a Planar Heat-Pipe Leading Edge
The sharp leading edges of a hypersonic vehicle are promising for the enhancement of its aerodynamic performance. However, they need a cooling mechanism because they are exposed to extremely high heat flux during reentry or hypersonic cruise, which easily heats up the surface materials beyond their temperature limits. This study explores the concept of a leading edge with planar heat-pipe cooling for which the whole inner surfaces are directly covered with a capillary wick. Its isothermal characteristic and simple configuration can provide robustness; however, due to the uniqueness of the planar type, the thermofluid characteristics should be investigated. Therefore, two kinds of heating tests (the inside visualization test and high-temperature test) were conducted using water as a working fluid. The gravity effects were surveyed, changing the test article attitude. The results showed that the planar concept worked as expected; no large temperature distribution was observed along both the chord and span directions, even in a nose-up attitude or a top heat configuration; the heat transfer performance was improved in nose-down attitude. During the heat-pipe operation, a heat transfer coefficient approximately 100 times higher than that of an evacuated operation was obtained. Visualizing inside the test article revealed that the screen mesh wick was properly covered with condensed water and that typical bubble formations of nucleate boiling were observed around the tip in some cases.
- 1 May 2019
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Spacecraft and Rockets
- Vol. 56 (3) , 771-779
Thermal Performance and Flow Visualization of a Planar Heat-Pipe Leading Edge
The sharp leading edges of a hypersonic vehicle are promising for the enhancement of its aerodynamic performance. However, they need a cooling mechanism because they are exposed to extremely high heat flux during reentry or hypersonic cruise, which easily heats up the surface materials beyond their temperature limits. This study explores the concept of a leading edge with planar heat-pipe cooling for which the whole inner surfaces are directly covered with a capillary wick. Its isothermal characteristic and simple configuration can provide robustness; however, due to the uniqueness of the planar type, the thermofluid characteristics should be investigated. Therefore, two kinds of heating tests (the inside visualization test and high-temperature test) were conducted using water as a working fluid. The gravity effects were surveyed, changing the test article attitude. The results showed that the planar concept worked as expected; no large temperature distribution was observed along both the chord and span directions, even in a nose-up attitude or a top heat configuration; the heat transfer performance was improved in nose-down attitude. During the heat-pipe operation, a heat transfer coefficient approximately 100 times higher than that of an evacuated operation was obtained. Visualizing inside the test article revealed that the screen mesh wick was properly covered with condensed water and that typical bubble formations of nucleate boiling were observed around the tip in some cases.
- 13 September 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (11) , 164
Development of a 300 L Calibration Bath for Oceanographic Thermometers
- 13 September 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (11) , 164
Development of a 300 L Calibration Bath for Oceanographic Thermometers
- 31 August 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (10) , 156
Estimating Surface Temperature of a Calibration Apparatus for Contact Surface Thermometers from Its Internal Temperature Profile
- 31 August 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (10) , 156
Estimating Surface Temperature of a Calibration Apparatus for Contact Surface Thermometers from Its Internal Temperature Profile
- 8 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (10518223) , 1
Johnson Noise Thermometry Based On Integrated Quantum Voltage Noise Source
We performed Johnson noise thermometry (JNT) using an integrated quantum voltage noise source (IQVNS) that generates pseudorandom noise with an RMS value determined by the product of the flux quantum, the clock frequency of IQVNS, fclk, and a calculable coefficient. The working principle is different from the conventional QVNS. The waveform of the IQVNS was analyzed thoroughly, and the source checked to see that it worked properly as intended, particularly in regard to its applicability as a reference for JNT measurements. The thermal noise power of a resistor at the triple point of water was measured with the IQVNS to derive a value of the Boltzmann constant.
- 8 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (10518223) , 1
Johnson Noise Thermometry Based On Integrated Quantum Voltage Noise Source
We performed Johnson noise thermometry (JNT) using an integrated quantum voltage noise source (IQVNS) that generates pseudorandom noise with an RMS value determined by the product of the flux quantum, the clock frequency of IQVNS, fclk, and a calculable coefficient. The working principle is different from the conventional QVNS. The waveform of the IQVNS was analyzed thoroughly, and the source checked to see that it worked properly as intended, particularly in regard to its applicability as a reference for JNT measurements. The thermal noise power of a resistor at the triple point of water was measured with the IQVNS to derive a value of the Boltzmann constant.
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 03004
Final report on APMP.T-K7 key comparison of water triple point cells
APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2016
- Published by IOP Publishing in Metrologia
- Vol. 53 (1A) , 03004
Final report on APMP.T-K7 key comparison of water triple point cells
APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- Open Access
- 1 November 2015
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 32 (11) , 2199-2210
Deep Ocean Temperature Measurement with an Uncertainty of 0.7 mK
The uncertainty of deep ocean temperature (~1°C) measurement was evaluated. The time drifts of six deep ocean standards thermometers were examined based on laboratory calibrations as performed by the manufacturer in triple point of water (TPW) cells and gallium-melting-point (GaMP) cells. The time drifts ranged from −0.11 to 0.14 mK yr−1. Three of the six thermometers were evaluated at the National Metrology Institute of Japan in five TPW cells and a GaMP cell, and the temperature readings agreed with the realized temperature of the national standard cells of Japan within ±0.14 and ±0.41 mK for TPW and GaMP, respectively. The pressure sensitivities of the deep ocean standards thermometers were estimated by comparison with conductivity–temperature–depth (CTD) thermometers in the deep ocean, and no notable difference was detected. Pressure sensitivities of the two CTD thermometers were examined by laboratory tests, and the results suggest that the deep ocean standards thermometers have no pressure sensitivity, at least up to 65 MPa. The position and attitude motion of the CTD system can affect temperature and salinity data quality. The overall expanded uncertainty of the deep ocean temperature measurement (up to 65 MPa) by the CTD thermometer calibrated in reference to the deep ocean standards thermometer is estimated to be 0.7 mK.
- 1 November 2015
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 32 (11) , 2199-2210
Open AccessDeep Ocean Temperature Measurement with an Uncertainty of 0.7 mK
The uncertainty of deep ocean temperature (~1°C) measurement was evaluated. The time drifts of six deep ocean standards thermometers were examined based on laboratory calibrations as performed by the manufacturer in triple point of water (TPW) cells and gallium-melting-point (GaMP) cells. The time drifts ranged from −0.11 to 0.14 mK yr−1. Three of the six thermometers were evaluated at the National Metrology Institute of Japan in five TPW cells and a GaMP cell, and the temperature readings agreed with the realized temperature of the national standard cells of Japan within ±0.14 and ±0.41 mK for TPW and GaMP, respectively. The pressure sensitivities of the deep ocean standards thermometers were estimated by comparison with conductivity–temperature–depth (CTD) thermometers in the deep ocean, and no notable difference was detected. Pressure sensitivities of the two CTD thermometers were examined by laboratory tests, and the results suggest that the deep ocean standards thermometers have no pressure sensitivity, at least up to 65 MPa. The position and attitude motion of the CTD system can affect temperature and salinity data quality. The overall expanded uncertainty of the deep ocean temperature measurement (up to 65 MPa) by the CTD thermometer calibrated in reference to the deep ocean standards thermometer is estimated to be 0.7 mK.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Development of Johnson Noise Thermometer Using Quantum Voltage Noise Source
In an effort to refine the value of the Boltzmann constant (k), we made thermodynamic temperature measurements of k using a Johnson noise thermometry (JNT) system, currently under development, using a quantum voltage noise source (QVNS). The JNT system measures the power spectrum density (PSD) of a sensor resistor using the PSD of a QVNS as a reference. k is then obtained using the Johnson-Nyquist equation. k obtained in our measurements to date has an offset of + (3.7±0.1)×10 -5 from the CODATA value.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Development of Johnson Noise Thermometer Using Quantum Voltage Noise Source
In an effort to refine the value of the Boltzmann constant (k), we made thermodynamic temperature measurements of k using a Johnson noise thermometry (JNT) system, currently under development, using a quantum voltage noise source (QVNS). The JNT system measures the power spectrum density (PSD) of a sensor resistor using the PSD of a QVNS as a reference. k is then obtained using the Johnson-Nyquist equation. k obtained in our measurements to date has an offset of + (3.7±0.1)×10 -5 from the CODATA value.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 124-129
Anomalous behavior of a tin point cell
At NMIJ, AIST, ensembles of fixed point cells are maintained for each defining fixed point to underpin the confidence for the maintenance of the national standards for thermometry. As a routine work, fixed point cells for the same temperature are realized simultaneously and the temperature differences between them are measured when the liquid fraction (1/F) is between 1 and 2. An anomalous temperature difference of approximately 0.2 mK was observed for one tin point cell. In this paper, we report the details of this anomalous temperature difference, and also the analysis to elucidate its cause. We assume that such anomalous behavior probably occurred due to condensation of impurities by employing a specific realization method repeatedly. Also we present that the anomalous behavior appears to be resolved by adopting another realization method during the experiments conducted under the present work.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 124-129
Anomalous behavior of a tin point cell
At NMIJ, AIST, ensembles of fixed point cells are maintained for each defining fixed point to underpin the confidence for the maintenance of the national standards for thermometry. As a routine work, fixed point cells for the same temperature are realized simultaneously and the temperature differences between them are measured when the liquid fraction (1/F) is between 1 and 2. An anomalous temperature difference of approximately 0.2 mK was observed for one tin point cell. In this paper, we report the details of this anomalous temperature difference, and also the analysis to elucidate its cause. We assume that such anomalous behavior probably occurred due to condensation of impurities by employing a specific realization method repeatedly. Also we present that the anomalous behavior appears to be resolved by adopting another realization method during the experiments conducted under the present work.
- 13 February 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 2002-2026
Electrical Effect in Silver-Point Realization Due to Cell Structure and Bias Voltage Based on Resistance Measurement Using AC and DC Bridges
- 13 February 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 2002-2026
Electrical Effect in Silver-Point Realization Due to Cell Structure and Bias Voltage Based on Resistance Measurement Using AC and DC Bridges
- 1 July 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (6-7) , 985-998
Boltzmann Constant Measurements Using QVNS-Based Johnson Noise Thermometry at NMIJ, AIST
- 1 July 2014
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 35 (6-7) , 985-998
Boltzmann Constant Measurements Using QVNS-Based Johnson Noise Thermometry at NMIJ, AIST