Hester Volten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hester Volten has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
A. J. C. Berkhout
Centre for Environmental Monitoring, Netherlands National Institute for Public Health and the Environment (RIVM), P.O. Box 1, 3720 BA Bilthoven, The Netherlands
2 shared publicationsD. P. J. Swart
Centre for Environmental Monitoring, Netherlands National Institute for Public Health and the Environment (RIVM), P.O. Box 1, 3720 BA Bilthoven, The Netherlands
2 shared publicationsJ. B. Bergwerff
Centre for Environmental Monitoring, Netherlands National Institute for Public Health and the Environment (RIVM), P.O. Box 1, 3720 BA Bilthoven, The Netherlands
2 shared publications- Arnoud Apituley
Royal Netherlands Meteorological Institute (KNMI), Ministry of Infrastructure and Water management, Utrech, The Netherlands
1 shared publication C. J. M. Potma
Centre for Environmental Monitoring, Netherlands National Institute for Public Health and the Environment (RIVM), P.O. Box 1, 3720 BA Bilthoven, The Netherlands
1 shared publication- Christa Blokhuis
National Institute for Public Health and the Environment (RIVM), P.O. Box 1, 3720 BA Bilthoven, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 1 August 2019
- Published by MDPI AG in Atmosphere
- Vol. 10 (8) , 445
Development and Implementation of a Platform for Public Information on Air Quality, Sensor Measurements, and Citizen Science
The use of low-cost sensors for air quality measurements is expanding rapidly, with an associated rise in the number of citizens measuring air quality themselves. This has major implications for traditional air quality monitoring as performed by Environmental Protection Agencies. Here we reflect on the experiences of the Dutch Institute for Public Health and the Environment (RIVM) with the use of low-cost sensors, particularly NO2 and PM10/PM2.5-sensors, and related citizen science, over the last few years. Specifically, we discuss the Dutch Innovation Program for Environmental Monitoring, which comprises the development of a knowledge portal and sensor data portal, new calibration approaches for sensors, and modelling and assimilation techniques for incorporating these uncertain sensor data into air pollution models. Finally, we highlight some of the challenges that come with the use of low-cost sensors for air quality monitoring, and give some specific use-case examples. Our results show that low-cost sensors can be a valuable addition to traditional air quality monitoring, but so far, their use in official monitoring has been limited. More research is needed to establish robust calibration methods while ongoing work is also aimed at a better understanding of the public’s needs for air quality information to optimize the use of low-cost sensors.
- 1 August 2019
- Published by MDPI AG in Atmosphere
- Vol. 10 (8) , 445
Open AccessDevelopment and Implementation of a Platform for Public Information on Air Quality, Sensor Measurements, and Citizen Science
The use of low-cost sensors for air quality measurements is expanding rapidly, with an associated rise in the number of citizens measuring air quality themselves. This has major implications for traditional air quality monitoring as performed by Environmental Protection Agencies. Here we reflect on the experiences of the Dutch Institute for Public Health and the Environment (RIVM) with the use of low-cost sensors, particularly NO2 and PM10/PM2.5-sensors, and related citizen science, over the last few years. Specifically, we discuss the Dutch Innovation Program for Environmental Monitoring, which comprises the development of a knowledge portal and sensor data portal, new calibration approaches for sensors, and modelling and assimilation techniques for incorporating these uncertain sensor data into air pollution models. Finally, we highlight some of the challenges that come with the use of low-cost sensors for air quality monitoring, and give some specific use-case examples. Our results show that low-cost sensors can be a valuable addition to traditional air quality monitoring, but so far, their use in official monitoring has been limited. More research is needed to establish robust calibration methods while ongoing work is also aimed at a better understanding of the public’s needs for air quality information to optimize the use of low-cost sensors.
- Open Access
- 21 February 2012
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 5 (2) , 413-427
Two instruments based on differential optical absorption spectroscopy (DOAS) to measure accurate ammonia concentrations in the atmosphere
We present two Differential Optical Absorption Spectroscopy (DOAS) instruments built at RIVM: the RIVM DOAS and the miniDOAS. Both instruments provide virtually interference-free measurements of NH3 concentrations in the atmosphere, since they measure over an open path, without suffering from inlet problems or interference problems by ammonium aerosols dissociating on tubes or filters. They measure concentrations up to at least 200 μg m−3, have a fast response, low maintenance demands, and a high up-time. The RIVM DOAS has a high accuracy of typically 0.15 μg m−3 for ammonia for 5-min averages and over a total light path of 100 m. The miniDOAS has been developed for application in measurement networks such as the Dutch National Air Quality Monitoring Network (LML). Compared to the RIVM DOAS it has a similar accuracy, but is significantly reduced in size, costs, and handling complexity. The RIVM DOAS and miniDOAS results showed excellent agreement (R2 = 0.996) during a field measurement campaign in Vredepeel, the Netherlands. This measurement site is located in an agricultural area and is characterized by highly variable, but on average high ammonia concentrations in the air. The RIVM-DOAS and miniDOAS results were compared to the results of the AMOR instrument, a continuous-flow wet denuder system, which is currently used in the LML. Averaged over longer time spans of typically a day, the (mini)DOAS and AMOR results agree reasonably well, although an offset of the AMOR values compared to the (mini)DOAS results exists. On short time scales, the (mini)DOAS shows a faster response and does not show the memory effects due to inlet tubing and transport of absorption fluids encountered by the AMOR. Due to its high accuracy, high uptime, low maintenance and its open path, the (mini)DOAS shows a good potential for flux measurements by using two (or more) systems in a gradient set-up and applying the aerodynamic gradient technique.
- 21 February 2012
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 5 (2) , 413-427
Open AccessTwo instruments based on differential optical absorption spectroscopy (DOAS) to measure accurate ammonia concentrations in the atmosphere
We present two Differential Optical Absorption Spectroscopy (DOAS) instruments built at RIVM: the RIVM DOAS and the miniDOAS. Both instruments provide virtually interference-free measurements of NH3 concentrations in the atmosphere, since they measure over an open path, without suffering from inlet problems or interference problems by ammonium aerosols dissociating on tubes or filters. They measure concentrations up to at least 200 μg m−3, have a fast response, low maintenance demands, and a high up-time. The RIVM DOAS has a high accuracy of typically 0.15 μg m−3 for ammonia for 5-min averages and over a total light path of 100 m. The miniDOAS has been developed for application in measurement networks such as the Dutch National Air Quality Monitoring Network (LML). Compared to the RIVM DOAS it has a similar accuracy, but is significantly reduced in size, costs, and handling complexity. The RIVM DOAS and miniDOAS results showed excellent agreement (R2 = 0.996) during a field measurement campaign in Vredepeel, the Netherlands. This measurement site is located in an agricultural area and is characterized by highly variable, but on average high ammonia concentrations in the air. The RIVM-DOAS and miniDOAS results were compared to the results of the AMOR instrument, a continuous-flow wet denuder system, which is currently used in the LML. Averaged over longer time spans of typically a day, the (mini)DOAS and AMOR results agree reasonably well, although an offset of the AMOR values compared to the (mini)DOAS results exists. On short time scales, the (mini)DOAS shows a faster response and does not show the memory effects due to inlet tubing and transport of absorption fluids encountered by the AMOR. Due to its high accuracy, high uptime, low maintenance and its open path, the (mini)DOAS shows a good potential for flux measurements by using two (or more) systems in a gradient set-up and applying the aerodynamic gradient technique.
- Open Access
- 19 December 2009
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 114 (D24)
NO2 lidar profile measurements for satellite interpretation and validation
Satellite instruments are efficient detectors of air pollutants such as NO2. However, the interpretation of satellite retrievals is not a trivial matter. We describe a novel instrument, the RIVM NO2 mobile lidar, to measure tropospheric NO2 profiles for the interpretation and validation of satellite data. During the DANDELIONS campaign in 2006 we obtained an extensive collection of lidar NO2 profiles, coinciding with OMI and SCIAMACHY overpasses. On clear days and early mornings a comparison between lidar and in situ measurements showed excellent agreement. At other times the in situ monitors with molybdenum converters suffered from NOy interference. The lidar NO2 profiles indicated a well‐mixed boundary layer, with high NO2 concentrations in the boundary layer and concentrations above not differing significantly from zero. The boundary layer concentrations spanned a wide range, which likely depends on the wind directions and on the intensity of local (rush hour) traffic which varies with the day of the week. Large diurnal differences were mainly driven by the height of the boundary layer, although direct photolysis or photochemical processes also contribute. Small‐scale temporal and spatial variations in the NO2 concentrations of the order of 20–50% were measured, probably indicative of small‐scale eddies. A preliminary comparison between satellite and lidar data shows that the satellite data tend to overestimate the amount of NO2 in the troposphere compared to the lidar data.
- 19 December 2009
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 114 (D24)
Open AccessNO2 lidar profile measurements for satellite interpretation and validation
Satellite instruments are efficient detectors of air pollutants such as NO2. However, the interpretation of satellite retrievals is not a trivial matter. We describe a novel instrument, the RIVM NO2 mobile lidar, to measure tropospheric NO2 profiles for the interpretation and validation of satellite data. During the DANDELIONS campaign in 2006 we obtained an extensive collection of lidar NO2 profiles, coinciding with OMI and SCIAMACHY overpasses. On clear days and early mornings a comparison between lidar and in situ measurements showed excellent agreement. At other times the in situ monitors with molybdenum converters suffered from NOy interference. The lidar NO2 profiles indicated a well‐mixed boundary layer, with high NO2 concentrations in the boundary layer and concentrations above not differing significantly from zero. The boundary layer concentrations spanned a wide range, which likely depends on the wind directions and on the intensity of local (rush hour) traffic which varies with the day of the week. Large diurnal differences were mainly driven by the height of the boundary layer, although direct photolysis or photochemical processes also contribute. Small‐scale temporal and spatial variations in the NO2 concentrations of the order of 20–50% were measured, probably indicative of small‐scale eddies. A preliminary comparison between satellite and lidar data shows that the satellite data tend to overestimate the amount of NO2 in the troposphere compared to the lidar data.