Lianyou Xiong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lianyou Xiong has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
L. Q. Liu
Chinese Academy of Sciences
3 shared publicationsL. Zhang
Chinese Academy of Sciences
3 shared publications- Liqiang Liu
State Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China
2 shared publications N Peng
Key Laboratory of Cryogenics Technical Institute of Physics and Chemistry, CAS 100190 Beijing China
2 shared publicationsN. Peng
Chinese Academy of Sciences
2 shared publicationsB. Dong
Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, CAS, Beijing, China and Graduate University of Chinese Academy of Sciences, Beijing, China
1 shared publication
Latest Publications
- 20 November 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (11) , 1325
Development of a 4000W@4.5 K helium refrigerator for accelerator equipment in isotope preparation
- 20 November 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (11) , 1325
Development of a 4000W@4.5 K helium refrigerator for accelerator equipment in isotope preparation
- Open Access
- 27 August 2024
- Published by MDPI AG in Lubricants
- Vol. 12 (9) , 302
Numerical Computation and Experimental Research for Dynamic Properties of Ultra-High-Speed Rotor System Supported by Helium Hydrostatic Gas Bearings
This study delves into the dynamic behavior of ultra-high-speed rotor systems underpinned by helium hydrostatic gas bearings, with a focus on the impact of rotational velocity on system performance. We have formulated an integrative dynamic model that harmonizes the rotor motion equation with the transient Reynolds equation. This model has been meticulously resolved via the Finite Difference Method (FDM) and the Wilson-Θ technique. Our findings unveil intricate nonlinear dynamics, including 2T-periodic and multi-periodic oscillations, and underscore the pivotal role of first-order temporal fluctuations, which account for over 20% of the transient pressure at rotational speeds exceeding 95.0 krpm. Further, we have executed empirical studies to evaluate the system’s performance in practical settings. It is observed that when the ratio of low-frequency to fundamental frequency approaches 0.3 and the amplitude ratio exceeds 3, the vigilant monitoring of system stability and reliability is imperative. Collective insights from both computational simulations and experimental studies have enriched our understanding of the dynamic attributes of ultra-high-speed rotor systems. These revelations are crucial for the advancement of more efficacious and resilient rotor systems designed for high-speed applications.
- 27 August 2024
- Published by MDPI AG in Lubricants
- Vol. 12 (9) , 302
Open AccessNumerical Computation and Experimental Research for Dynamic Properties of Ultra-High-Speed Rotor System Supported by Helium Hydrostatic Gas Bearings
This study delves into the dynamic behavior of ultra-high-speed rotor systems underpinned by helium hydrostatic gas bearings, with a focus on the impact of rotational velocity on system performance. We have formulated an integrative dynamic model that harmonizes the rotor motion equation with the transient Reynolds equation. This model has been meticulously resolved via the Finite Difference Method (FDM) and the Wilson-Θ technique. Our findings unveil intricate nonlinear dynamics, including 2T-periodic and multi-periodic oscillations, and underscore the pivotal role of first-order temporal fluctuations, which account for over 20% of the transient pressure at rotational speeds exceeding 95.0 krpm. Further, we have executed empirical studies to evaluate the system’s performance in practical settings. It is observed that when the ratio of low-frequency to fundamental frequency approaches 0.3 and the amplitude ratio exceeds 3, the vigilant monitoring of system stability and reliability is imperative. Collective insights from both computational simulations and experimental studies have enriched our understanding of the dynamic attributes of ultra-high-speed rotor systems. These revelations are crucial for the advancement of more efficacious and resilient rotor systems designed for high-speed applications.
- Open Access
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012025
Numerical Study of the Performance Effect of Varying Vaneless Space in He Turboexpander Nozzles
A numerical analysis has been carried out on a 16 mm tip diameter radial-axial flow cryogenic turboexpander using He, in order to directly compare performance characteristics by varying the vaneless space. A reference nozzle with radial clearance 0.1 mm was used in the helium liquefaction system, and six other nozzles were designed with radial clearance of 0.3 mm, 0.5 mm, 0.8 mm, 1.0 mm, 1.2 mm and 1.5 mm. As part of the design process a series of CFD simulations were carried out in order to guide design iterations towards achieving a matched flow capacity for each design. In this way the variations in the stage efficiency could be attributed to the different vaneless space only, thus allowing direct comparisons to be made. The variation in computed efficiency was used to recommend optimum value of the ratio of the nozzle vane trailing edge radius to the rotor leading edge radius (R te/r le).
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012025
Open AccessNumerical Study of the Performance Effect of Varying Vaneless Space in He Turboexpander Nozzles
A numerical analysis has been carried out on a 16 mm tip diameter radial-axial flow cryogenic turboexpander using He, in order to directly compare performance characteristics by varying the vaneless space. A reference nozzle with radial clearance 0.1 mm was used in the helium liquefaction system, and six other nozzles were designed with radial clearance of 0.3 mm, 0.5 mm, 0.8 mm, 1.0 mm, 1.2 mm and 1.5 mm. As part of the design process a series of CFD simulations were carried out in order to guide design iterations towards achieving a matched flow capacity for each design. In this way the variations in the stage efficiency could be attributed to the different vaneless space only, thus allowing direct comparisons to be made. The variation in computed efficiency was used to recommend optimum value of the ratio of the nozzle vane trailing edge radius to the rotor leading edge radius (R te/r le).
- Open Access
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012003
Helium extraction and nitrogen removal from LNG boil-off gas
The helium bearing boil off gas (BOG) from liquid natural gas (LNG) storage tank in LNG plant, which has a helium concentration of about 1%, has attracted the attention in China as a new helium source. As the BOG is usually reused by re-condensing to recover methane, it is likely to cause continuous accumulation of nitrogen in the unit, thus a nitrogen removal process must be integrated. This paper describes a conceptional cryogenic separation system aiming at recovering methane, helium and nitrogen from BOG based on cryogenic distillation and condensation process.
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012003
Open AccessHelium extraction and nitrogen removal from LNG boil-off gas
The helium bearing boil off gas (BOG) from liquid natural gas (LNG) storage tank in LNG plant, which has a helium concentration of about 1%, has attracted the attention in China as a new helium source. As the BOG is usually reused by re-condensing to recover methane, it is likely to cause continuous accumulation of nitrogen in the unit, thus a nitrogen removal process must be integrated. This paper describes a conceptional cryogenic separation system aiming at recovering methane, helium and nitrogen from BOG based on cryogenic distillation and condensation process.
- 1 May 2016
- Vol. 20 (9) , 1888-93
Renoprotective effect of atorvastatin on STZ-diabetic rats through inhibiting inflammatory factors expression in diabetic rat.
Though increasing evidences showed that statins had potential benefits to diabetic kidney disease (DKD), its mechanism has not been completely elucidated yet. The aim of this study was to investigate the renoprotective effects of atorvastatin on DKD. Kidney injury was induced by streptozotocin (STZ) in rats. STZ-diabetic rats were treated with atorvastatin (10 mg/kg/d) for consecutive 8 weeks. Renal functional and morphological changes were evaluated by clinical biochemistry and histological examination. The expression of inflammatory factors in kidney was measured by real-time (RT)-PCR and enzyme-linked immunosorbent assay (ELISA). Compared with DKD rat, atorvastatin effectively reduced the levels of low-density lipoprotein cholesterol (LDL-C), creatinine (CREA), ratio of urine albumin to creatinine (UACR) (p <0.05). The expression of inflammatory factors TNF-α, MCP-1 and IL-6 in kidney tissue were significantly down-regulated, as well (p <0.05). Atorvastatin improved kidney injury with the reduced morphologic lesions and renal fibrosis and the increasing transforming growth factor-β (TGF-β) and collagen I staining. Our results suggested that atorvastatin could ameliorate DKD through inhibiting pro-inflammatory pathways. Atorvastatin may possess a potential antidiabetic effect and serve as the therapeutic drug for DKD management.
- 1 May 2016
- Vol. 20 (9) , 1888-93
Renoprotective effect of atorvastatin on STZ-diabetic rats through inhibiting inflammatory factors expression in diabetic rat.
Though increasing evidences showed that statins had potential benefits to diabetic kidney disease (DKD), its mechanism has not been completely elucidated yet. The aim of this study was to investigate the renoprotective effects of atorvastatin on DKD. Kidney injury was induced by streptozotocin (STZ) in rats. STZ-diabetic rats were treated with atorvastatin (10 mg/kg/d) for consecutive 8 weeks. Renal functional and morphological changes were evaluated by clinical biochemistry and histological examination. The expression of inflammatory factors in kidney was measured by real-time (RT)-PCR and enzyme-linked immunosorbent assay (ELISA). Compared with DKD rat, atorvastatin effectively reduced the levels of low-density lipoprotein cholesterol (LDL-C), creatinine (CREA), ratio of urine albumin to creatinine (UACR) (p <0.05). The expression of inflammatory factors TNF-α, MCP-1 and IL-6 in kidney tissue were significantly down-regulated, as well (p <0.05). Atorvastatin improved kidney injury with the reduced morphologic lesions and renal fibrosis and the increasing transforming growth factor-β (TGF-β) and collagen I staining. Our results suggested that atorvastatin could ameliorate DKD through inhibiting pro-inflammatory pathways. Atorvastatin may possess a potential antidiabetic effect and serve as the therapeutic drug for DKD management.
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 825
A new cryostat for precise temperature control
Gifford-McMahon (GM) cryocoolers are often used in cryostat as cold sources. It has advantages of simple structure and low operating cost as well as disadvantages of vibration and temperature oscillation, which are fatal for some applications that are very sensitive to temperature stability at low temperature. To solve the problem, a thermal analysis model which is used to simulate heat transfer in the cryostat is built and discussed. According to the analysis results, a cryostat that can provide variable temperature (4-20 K) for the accurate temperature control experiments is designed and manufactured. In this cryostat, a polytetrafluoroethylene (PTFE) sheet is used as a thermal damper to reduce the temperature oscillation, with which, the temperature oscillation of the sample cooling holder is less than 4 mK at the 20 K region.
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 825
A new cryostat for precise temperature control
Gifford-McMahon (GM) cryocoolers are often used in cryostat as cold sources. It has advantages of simple structure and low operating cost as well as disadvantages of vibration and temperature oscillation, which are fatal for some applications that are very sensitive to temperature stability at low temperature. To solve the problem, a thermal analysis model which is used to simulate heat transfer in the cryostat is built and discussed. According to the analysis results, a cryostat that can provide variable temperature (4-20 K) for the accurate temperature control experiments is designed and manufactured. In this cryostat, a polytetrafluoroethylene (PTFE) sheet is used as a thermal damper to reduce the temperature oscillation, with which, the temperature oscillation of the sample cooling holder is less than 4 mK at the 20 K region.
- 12 January 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 23 (6) , 1087-1090
Recent Activities of TIPC on Cryogenic Systems Used for Superconducting Accelerators in China
- 12 January 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 23 (6) , 1087-1090
Recent Activities of TIPC on Cryogenic Systems Used for Superconducting Accelerators in China
- 8 January 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 23 (6) , 1133-1135
Economical Running of BEPCII Cryogenic System
- 8 January 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 23 (6) , 1133-1135
Economical Running of BEPCII Cryogenic System
- 30 December 2009
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 23 (6) , 1123-1126
Thermal Analysis of a Superconducting Magnet Stabilization Using a 3D Simulative Finite Element Model
- 30 December 2009
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 23 (6) , 1123-1126
Thermal Analysis of a Superconducting Magnet Stabilization Using a 3D Simulative Finite Element Model