Liqiang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Liqiang Liu has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
B. Dong
Technical Institute of Physics and Chemistry, CAS, Beijing, 100190 China
3 shared publications- Changlei Ke
Technical Institute of Physics and Chemistry
2 shared publications G. Zhou
Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, CAS, Beijing, China
2 shared publications- Kongrong Li
Technical Institute of Physics and Chemistry
2 shared publications - Lianyou Xiong
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, China
2 shared publications - Nan Peng
Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
2 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by SAGE Publications in Science Progress
- Vol. 108 (3)
Numerical research of slosh characteristics by baffles in the liquid helium portable tank
This article addresses the challenges posed by the unique vapor–liquid physical properties of helium, specifically, focusing on the slosh of liquid helium caused by shaking during transportation. A three-dimensional model of a baffle structure is developed to prevent sloshing in the liquid helium portable tanks. Literature-based verification of simulation model via gas–liquid interface data shows 2 is identified. Investigating vapor–liquid phase, pressure, and velocity variations with/without baffles in liquid helium tanks. Additionally, the variation in liquid phase fraction with baffle is analyzed to assess their effectiveness in mitigating internal pressure impact during the storage and transportation. These insights hold significant implications for ensuring safe and efficient transportation of liquid helium on highways.
- 1 July 2025
- Published by SAGE Publications in Science Progress
- Vol. 108 (3)
Open AccessNumerical research of slosh characteristics by baffles in the liquid helium portable tank
This article addresses the challenges posed by the unique vapor–liquid physical properties of helium, specifically, focusing on the slosh of liquid helium caused by shaking during transportation. A three-dimensional model of a baffle structure is developed to prevent sloshing in the liquid helium portable tanks. Literature-based verification of simulation model via gas–liquid interface data shows 2 is identified. Investigating vapor–liquid phase, pressure, and velocity variations with/without baffles in liquid helium tanks. Additionally, the variation in liquid phase fraction with baffle is analyzed to assess their effectiveness in mitigating internal pressure impact during the storage and transportation. These insights hold significant implications for ensuring safe and efficient transportation of liquid helium on highways.
- 12 May 2025
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 27 (22) , 3690-3699
A commercially scalable MOF adsorbent Cu-BTC for helium recovery from natural gas: performance and mechanism studies at room temperature and lower temperatures
Cu-BTC shows good CO 2 /He, CH 4 /He, and N 2 /He separation performance, with enhanced performance at lower temperatures. The adsorption capacity and selectivity of Cu-BTC for helium-containing mixed gases are dominated by its open metal sites.
- 12 May 2025
- Published by Royal Society of Chemistry (RSC) in CrystEngComm
- Vol. 27 (22) , 3690-3699
A commercially scalable MOF adsorbent Cu-BTC for helium recovery from natural gas: performance and mechanism studies at room temperature and lower temperatures
Cu-BTC shows good CO 2 /He, CH 4 /He, and N 2 /He separation performance, with enhanced performance at lower temperatures. The adsorption capacity and selectivity of Cu-BTC for helium-containing mixed gases are dominated by its open metal sites.
- 27 November 2024
- Published by ASME International in Journal of Computational and Nonlinear Dynamics
- Vol. 20 (1) , 1-12
Investigation of Nonlinear Dynamic Behaviors of Vertical Rotor System Supported by Aerostatic Bearings
A common issue associated with gas bearing–rotor systems is the tendency to generate self-excited vibrations, leading to instability. To address this problem, the fluid–structure coupling model of an aerostatic bearing–rotor system is established in this paper. Then, a hybrid method combining the finite difference method (FDM) and direct integration method is employed to solve the bearing lubrication equation and rotor motion equation simultaneously. Furthermore, based on the orbits of rotor center, frequency spectrum diagrams, Poincaré maps, waterfall diagrams, and bifurcation diagrams, the effects of rotational speed, rotor mass, orifice diameter, and nominal clearance on the nonlinear dynamic behaviors of the bearing–rotor system are investigated. The results indicate that the system exhibits rich nonlinear behaviors with increasing rotational speed and rotor mass, including the occurrence of typical half-speed whirl. However, the nonlinear vibrations of the system can be restricted by selecting appropriate bearing structural parameters, providing theoretical guidance for the design of aerostatic bearing–rotor systems.
- 27 November 2024
- Published by ASME International in Journal of Computational and Nonlinear Dynamics
- Vol. 20 (1) , 1-12
Investigation of Nonlinear Dynamic Behaviors of Vertical Rotor System Supported by Aerostatic Bearings
A common issue associated with gas bearing–rotor systems is the tendency to generate self-excited vibrations, leading to instability. To address this problem, the fluid–structure coupling model of an aerostatic bearing–rotor system is established in this paper. Then, a hybrid method combining the finite difference method (FDM) and direct integration method is employed to solve the bearing lubrication equation and rotor motion equation simultaneously. Furthermore, based on the orbits of rotor center, frequency spectrum diagrams, Poincaré maps, waterfall diagrams, and bifurcation diagrams, the effects of rotational speed, rotor mass, orifice diameter, and nominal clearance on the nonlinear dynamic behaviors of the bearing–rotor system are investigated. The results indicate that the system exhibits rich nonlinear behaviors with increasing rotational speed and rotor mass, including the occurrence of typical half-speed whirl. However, the nonlinear vibrations of the system can be restricted by selecting appropriate bearing structural parameters, providing theoretical guidance for the design of aerostatic bearing–rotor systems.
- Open Access
- 27 August 2024
- Published by MDPI AG in Lubricants
- Vol. 12 (9) , 302
Numerical Computation and Experimental Research for Dynamic Properties of Ultra-High-Speed Rotor System Supported by Helium Hydrostatic Gas Bearings
This study delves into the dynamic behavior of ultra-high-speed rotor systems underpinned by helium hydrostatic gas bearings, with a focus on the impact of rotational velocity on system performance. We have formulated an integrative dynamic model that harmonizes the rotor motion equation with the transient Reynolds equation. This model has been meticulously resolved via the Finite Difference Method (FDM) and the Wilson-Θ technique. Our findings unveil intricate nonlinear dynamics, including 2T-periodic and multi-periodic oscillations, and underscore the pivotal role of first-order temporal fluctuations, which account for over 20% of the transient pressure at rotational speeds exceeding 95.0 krpm. Further, we have executed empirical studies to evaluate the system’s performance in practical settings. It is observed that when the ratio of low-frequency to fundamental frequency approaches 0.3 and the amplitude ratio exceeds 3, the vigilant monitoring of system stability and reliability is imperative. Collective insights from both computational simulations and experimental studies have enriched our understanding of the dynamic attributes of ultra-high-speed rotor systems. These revelations are crucial for the advancement of more efficacious and resilient rotor systems designed for high-speed applications.
- 27 August 2024
- Published by MDPI AG in Lubricants
- Vol. 12 (9) , 302
Open AccessNumerical Computation and Experimental Research for Dynamic Properties of Ultra-High-Speed Rotor System Supported by Helium Hydrostatic Gas Bearings
This study delves into the dynamic behavior of ultra-high-speed rotor systems underpinned by helium hydrostatic gas bearings, with a focus on the impact of rotational velocity on system performance. We have formulated an integrative dynamic model that harmonizes the rotor motion equation with the transient Reynolds equation. This model has been meticulously resolved via the Finite Difference Method (FDM) and the Wilson-Θ technique. Our findings unveil intricate nonlinear dynamics, including 2T-periodic and multi-periodic oscillations, and underscore the pivotal role of first-order temporal fluctuations, which account for over 20% of the transient pressure at rotational speeds exceeding 95.0 krpm. Further, we have executed empirical studies to evaluate the system’s performance in practical settings. It is observed that when the ratio of low-frequency to fundamental frequency approaches 0.3 and the amplitude ratio exceeds 3, the vigilant monitoring of system stability and reliability is imperative. Collective insights from both computational simulations and experimental studies have enriched our understanding of the dynamic attributes of ultra-high-speed rotor systems. These revelations are crucial for the advancement of more efficacious and resilient rotor systems designed for high-speed applications.
- Open Access
Numerical Study of the Effects of Injection Fluctuations on Liquid Nitrogen Spray Cooling
Spray cooling with liquid nitrogen is increasingly utilized as an efficient approach to achieve cryogenic cooling. Effects of injection mass flow rate fluctuations on the evaporation, temperature distribution, and droplet distribution of a spray field were examined by employing a validated Computational Fluid Dynamics (CFD) numerical model. The numerical results indicated that injection fluctuations enhanced the volume-averaging turbulent kinetic energy and promoted the evaporation of the whole spray field. The strengthened mass and heat transfer between the liquid nitrogen droplets and the surrounding vapor created by the fluctuating injection led to a lower temperature of the whole volume. A relatively smaller droplet size and a more inhomogeneous droplet distribution were obtained under the unsteady inlet. The changes of the frequency and the amplitude of the fluctuations had little effects on the overall spray development. The results could enrich the knowledge of the relation between the inevitable fluctuations and the overall spray development and the cooling performance in a practical spray cooling system with cryogenic fluids.
Open AccessNumerical Study of the Effects of Injection Fluctuations on Liquid Nitrogen Spray Cooling
Spray cooling with liquid nitrogen is increasingly utilized as an efficient approach to achieve cryogenic cooling. Effects of injection mass flow rate fluctuations on the evaporation, temperature distribution, and droplet distribution of a spray field were examined by employing a validated Computational Fluid Dynamics (CFD) numerical model. The numerical results indicated that injection fluctuations enhanced the volume-averaging turbulent kinetic energy and promoted the evaporation of the whole spray field. The strengthened mass and heat transfer between the liquid nitrogen droplets and the surrounding vapor created by the fluctuating injection led to a lower temperature of the whole volume. A relatively smaller droplet size and a more inhomogeneous droplet distribution were obtained under the unsteady inlet. The changes of the frequency and the amplitude of the fluctuations had little effects on the overall spray development. The results could enrich the knowledge of the relation between the inevitable fluctuations and the overall spray development and the cooling performance in a practical spray cooling system with cryogenic fluids.
- Open Access
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012026
Study of a multi-strategy controller on a helium liquefier
Helium liquefier is widely used in the fields of superconducting, nuclear fusion energy and high-energy physics. However, the present PID controlling system of the liquefier is not able to keep the compressor suction pressure, outlet pressure and turbine inlet pressure all in the expected range at the same time. Thus, a multi-strategy controller for a helium liquefier is proposed in this paper. A dynamic simulation model of this liquefier is also developed and shown. To study the control effect, an operation process including cool-down, steady-state and pulse of heat is described. The simulation result of this process is presented and compared with the result of the present PID controlling system.
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012026
Open AccessStudy of a multi-strategy controller on a helium liquefier
Helium liquefier is widely used in the fields of superconducting, nuclear fusion energy and high-energy physics. However, the present PID controlling system of the liquefier is not able to keep the compressor suction pressure, outlet pressure and turbine inlet pressure all in the expected range at the same time. Thus, a multi-strategy controller for a helium liquefier is proposed in this paper. A dynamic simulation model of this liquefier is also developed and shown. To study the control effect, an operation process including cool-down, steady-state and pulse of heat is described. The simulation result of this process is presented and compared with the result of the present PID controlling system.
- Open Access
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012010
Development of a measurement and control system for a 10 kW@20 K refrigerator based on Siemens PLC S7-300
A 10 kW@20 K refrigerator has been established by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this 10 kW@20 K refrigerator is developed. According to the detailed measurement requirements, proper sensors and transmitters are adopted. Siemens S7-300 PLC CPU315-2 PN/DP operates as a master station. Two sets of ET200M DP remote expand I/O, one power meter, two compressors and one vacuum gauge operate as slave stations. Profibus-DP field communication and Modbus communication are used between the master station and the slave stations in this control system. The upper computer HMI (Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. After commissioning, this refrigerator has been operating with a 10 kW of cooling power at 20 K for more than 72 hours.
- 28 February 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 171 (1) , 012010
Open AccessDevelopment of a measurement and control system for a 10 kW@20 K refrigerator based on Siemens PLC S7-300
A 10 kW@20 K refrigerator has been established by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this 10 kW@20 K refrigerator is developed. According to the detailed measurement requirements, proper sensors and transmitters are adopted. Siemens S7-300 PLC CPU315-2 PN/DP operates as a master station. Two sets of ET200M DP remote expand I/O, one power meter, two compressors and one vacuum gauge operate as slave stations. Profibus-DP field communication and Modbus communication are used between the master station and the slave stations in this control system. The upper computer HMI (Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. After commissioning, this refrigerator has been operating with a 10 kW of cooling power at 20 K for more than 72 hours.
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 156
Application of inverse heat conduction problem on temperature measurement
For regenerative cooling devices, such as G-M refrigerator, pulse tube cooler or thermoacoustic cooler, the gas oscillating bring about temperature fluctuations inevitably, which is harmful in many applications requiring high stable temperatures. To find out the oscillating mechanism of the cooling temperature and improve the temperature stability of cooler, the inner temperature of the cold head has to be measured. However, it is difficult to measure the inner oscillating temperature of the cold head directly because the invasive temperature detectors may disturb the oscillating flow. Fortunately, the outer surface temperature of the cold head can be measured accurately by invasive temperature measurement techniques. In this paper, a mathematical model of inverse heat conduction problem is presented to identify the inner surface oscillating temperature of cold head according to the measured temperature of the outer surface in a GM cryocooler. Inverse heat conduction problem will be solved using control volume approach. Outer surface oscillating temperature could be used as input conditions of inverse problem and the inner surface oscillating temperature of cold head can be inversely obtained. A simple uncertainty analysis of the oscillating temperature measurement also will be provided.
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 156
Application of inverse heat conduction problem on temperature measurement
For regenerative cooling devices, such as G-M refrigerator, pulse tube cooler or thermoacoustic cooler, the gas oscillating bring about temperature fluctuations inevitably, which is harmful in many applications requiring high stable temperatures. To find out the oscillating mechanism of the cooling temperature and improve the temperature stability of cooler, the inner temperature of the cold head has to be measured. However, it is difficult to measure the inner oscillating temperature of the cold head directly because the invasive temperature detectors may disturb the oscillating flow. Fortunately, the outer surface temperature of the cold head can be measured accurately by invasive temperature measurement techniques. In this paper, a mathematical model of inverse heat conduction problem is presented to identify the inner surface oscillating temperature of cold head according to the measured temperature of the outer surface in a GM cryocooler. Inverse heat conduction problem will be solved using control volume approach. Outer surface oscillating temperature could be used as input conditions of inverse problem and the inner surface oscillating temperature of cold head can be inversely obtained. A simple uncertainty analysis of the oscillating temperature measurement also will be provided.
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 825
A new cryostat for precise temperature control
Gifford-McMahon (GM) cryocoolers are often used in cryostat as cold sources. It has advantages of simple structure and low operating cost as well as disadvantages of vibration and temperature oscillation, which are fatal for some applications that are very sensitive to temperature stability at low temperature. To solve the problem, a thermal analysis model which is used to simulate heat transfer in the cryostat is built and discussed. According to the analysis results, a cryostat that can provide variable temperature (4-20 K) for the accurate temperature control experiments is designed and manufactured. In this cryostat, a polytetrafluoroethylene (PTFE) sheet is used as a thermal damper to reduce the temperature oscillation, with which, the temperature oscillation of the sample cooling holder is less than 4 mK at the 20 K region.
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 825
A new cryostat for precise temperature control
Gifford-McMahon (GM) cryocoolers are often used in cryostat as cold sources. It has advantages of simple structure and low operating cost as well as disadvantages of vibration and temperature oscillation, which are fatal for some applications that are very sensitive to temperature stability at low temperature. To solve the problem, a thermal analysis model which is used to simulate heat transfer in the cryostat is built and discussed. According to the analysis results, a cryostat that can provide variable temperature (4-20 K) for the accurate temperature control experiments is designed and manufactured. In this cryostat, a polytetrafluoroethylene (PTFE) sheet is used as a thermal damper to reduce the temperature oscillation, with which, the temperature oscillation of the sample cooling holder is less than 4 mK at the 20 K region.
- 1 January 1988
- Vol. 15 (6) , 436-41
[Comparative studies on renaturation kinetics of Alligator sinensis and Alligator mississippiensis and their organization of the genomes].
- 1 January 1988
- Vol. 15 (6) , 436-41
[Comparative studies on renaturation kinetics of Alligator sinensis and Alligator mississippiensis and their organization of the genomes].