PTPierre Touboul

Pierre Touboul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pierre Touboul has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MICROSCOPE Satellite and its Drag-Free and Attitude Control System

    by Alain Robert, Valerio Cipolla, Pascal Prieur, Pierre Touboul, Gilles Métris, Manuel Rodrigues, Yves André, Joel Bergé, Damien Boulanger, Ratana Chhun, et al.

    This paper focus on the description of the design and performance of the MICROSCOPE satellite and its Drag-Free and Attitude Control System (DFACS). The satellite is derived from CNES' Myriade platform family, albeit with significant upgrades dictated by the unprecedented MICROSCOPE's mission requirements. The 300kg drag-free microsatellite has completed its 2-year flight with higher-than-expected performances. Its passive thermal concept allowed for variations smaller than 1 $\mu$K at the measurement frequency $f_{\rm{EP}}$. The propulsion system provided a 6 axis continuous and very low noise thrust from zero to some hundreds of micronewtons. Finally, the performance of its DFACS (aimed at compensating the disturbing forces and torques applied to the satellite) is the finest ever achieved in low Earth orbit, with residual accelerations along the three axes are lower than $10^{-12} {\rm m/s}^2$ at $f_{\rm{EP}}$ over 8 days.

  • Open Access

    MICROSCOPE mission analysis, requirements and expected performance

    by Pierre Touboul, Manuel Rodrigues, Gilles Métris, Ratana Chhun, Alain Robert, Quentin Baghi, Emilie Hardy, Joel Bergé, Damien Boulanger, Bruno Christophe, et al.

    The MICROSCOPE mission aimed to test the Weak Equivalence Principle (WEP) to a precision of $10^{-15}$. The WEP states that two bodies fall at the same rate on a gravitational field independently of their mass or composition. In MICROSCOPE, two masses of different compositions (titanium and platinum alloys) are placed on a quasi-circular trajectory around the Earth. They are the test-masses of a double accelerometer. The measurement of their accelerations is used to extract a potential WEP violation that would occur at a frequency defined by the motion and attitude of the satellite around the Earth. This paper details the major drivers of the mission leading to the specification of the major subsystems (satellite, ground segment, instrument, orbit...). Building upon the measurement equation, we derive the objective of the test in statistical and systematic error allocation and provide the mission's expected error budget.

  • Einstein rules at a precision of 2 × 10–14

    by Pierre Touboul, Manuel Rodrigues, Joel Bergé


  • Open Access

    The MICROSCOPE mission: first results of a space test of the Equivalence Principle

    by Pierre Touboul, Gilles Métris, Manuel Rodrigues, Yves André, Quentin Baghi, Joel Bergé, Damien Boulanger, Stefanie Bremer, Patrice Carle, Ratana Chhun, et al.

    According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of the Equivalence Principle, or to the discovery of a new long-range force. Analysis of the first data gives $\delta\rm{(Ti,Pt)}= [-1 \pm 9 (\mathrm{stat}) \pm 9 (\mathrm{syst})] \times 10^{-15}$ (1$\sigma$ statistical uncertainty) for the titanium-platinum E\"otv\"os parameter characterizing the relative difference in their free-fall accelerations.

  • Open Access

    Validation of the in-flight calibration procedures for the MICROSCOPE space mission

    by Emilie Hardy, Agnès Levy, Manuel Rodrigues, Pierre Touboul, Gilles Métris

    The MICROSCOPE space mission aims to test the Equivalence Principle with an accuracy of $10^{-15}$. The drag-free micro-satellite will orbit around the Earth and embark a differential electrostatic accelerometer including two cylindrical test masses submitted to the same gravitational field and made of different materials. The experience consists in testing the equality of the electrostatic acceleration applied to the masses to maintain them relatively motionless. The accuracy of the measurements exploited for the test of the Equivalence Principle is limited by our a priori knowledge of several physical parameters of the instrument. These parameters are partially estimated on-ground, but with an insufficient accuracy, and an in-orbit calibration is therefore required to correct the measurements. The calibration procedures have been defined and their analytical performances have been evaluated. In addition, a simulator software including the dynamics model of the instrument, the satellite drag-free system and the perturbing environment has been developed to numerically validate the analytical results. After an overall presentation of the MICROSCOPE mission, this paper will describe the calibration procedures and focus on the simulator. Such an in-flight calibration is mandatory for similar space missions taking advantage of a drag-free system.

  • CHAMP, GRACE, GOCE Instruments and Beyond

    by P. Touboul, B. Foulon, B. Christophe, J. P. Marque