Lewis Rubinson
Research Subjects
Lewis Rubinson has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Ann Knebel
1 shared publication- Carl Rrt Hinkson
Respiratory Care Department, Harborview Medical Center, University of Washington, Seattle, WA, USA
1 shared publication - David J. Pierson
Division of Pulmonary and Critical Care Medicine, Harborview Medical Center, 325 Ninth Avenue, Box 359762, Seattle, WA 98104, USA
1 shared publication - David L. Hotchkin1 shared publication
Frances Vaughn
1 shared publicationJohn L. Hick
1 shared publication
Latest Publications
- 1 March 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (3) , 527-532
A porcine model for initial surge mechanical ventilator assessment and evaluation of two limited-function ventilators*
Objectives: To adapt an animal model of acute lung injury for use as a standard protocol for a screening initial evaluation of limited function, or “surge,” ventilators for use in mass casualty scenarios. Design: Prospective, experimental animal study. Setting: University research laboratory. Subjects: Twelve adult pigs. Interventions: Twelve spontaneously breathing pigs (six in each group) were subjected to acute lung injury/acute respiratory distress syndrome via pulmonary artery infusion of oleic acid. After development of respiratory failure, animals were mechanically ventilated with a limited-function ventilator (simplified automatic ventilator [SAVe] I or II; Automedx, Germantown, MD) for 1 hr or until the ventilator could not support the animal. The limited-function ventilator was then exchanged for a full-function ventilator (Servo 900C; Siemens-Elema, Solna, Sweden). Measurements and Main Results: Reliable and reproducible levels of acute lung injury/acute respiratory distress syndrome were induced. The SAVe I was unable to adequately oxygenate five animals with Pao2 (52.0 ± 11.1 torr) compared to the Servo (106.0 ± 25.6 torr; p = .002). The SAVe II was able to oxygenate and ventilate all six animals for 1 hr with no difference in Pao2 (141.8 ± 169.3 torr) compared to the Servo (158.3 ± 167.7 torr). Conclusions: We describe a novel in vivo model of acute lung injury/acute respiratory distress syndrome that can be used to initially screen limited-function ventilators considered for mass respiratory failure stockpiles and that is intended to be combined with additional studies to definitively assess appropriateness for mass respiratory failure. Specifically, during this study we demonstrate that the SAVe I ventilator is unable to provide sufficient gas exchange, whereas the SAVe II, with several more functions, was able to support the same level of hypoxemic respiratory failure secondary to acute lung injury/acute respiratory distress syndrome for 1 hr.
- 1 March 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (3) , 527-532
A porcine model for initial surge mechanical ventilator assessment and evaluation of two limited-function ventilators*
Objectives: To adapt an animal model of acute lung injury for use as a standard protocol for a screening initial evaluation of limited function, or “surge,” ventilators for use in mass casualty scenarios. Design: Prospective, experimental animal study. Setting: University research laboratory. Subjects: Twelve adult pigs. Interventions: Twelve spontaneously breathing pigs (six in each group) were subjected to acute lung injury/acute respiratory distress syndrome via pulmonary artery infusion of oleic acid. After development of respiratory failure, animals were mechanically ventilated with a limited-function ventilator (simplified automatic ventilator [SAVe] I or II; Automedx, Germantown, MD) for 1 hr or until the ventilator could not support the animal. The limited-function ventilator was then exchanged for a full-function ventilator (Servo 900C; Siemens-Elema, Solna, Sweden). Measurements and Main Results: Reliable and reproducible levels of acute lung injury/acute respiratory distress syndrome were induced. The SAVe I was unable to adequately oxygenate five animals with Pao2 (52.0 ± 11.1 torr) compared to the Servo (106.0 ± 25.6 torr; p = .002). The SAVe II was able to oxygenate and ventilate all six animals for 1 hr with no difference in Pao2 (141.8 ± 169.3 torr) compared to the Servo (158.3 ± 167.7 torr). Conclusions: We describe a novel in vivo model of acute lung injury/acute respiratory distress syndrome that can be used to initially screen limited-function ventilators considered for mass respiratory failure stockpiles and that is intended to be combined with additional studies to definitively assess appropriateness for mass respiratory failure. Specifically, during this study we demonstrate that the SAVe I ventilator is unable to provide sufficient gas exchange, whereas the SAVe II, with several more functions, was able to support the same level of hypoxemic respiratory failure secondary to acute lung injury/acute respiratory distress syndrome for 1 hr.
- 1 December 2010
- Published by Cambridge University Press (CUP) in Disaster Medicine and Public Health Preparedness
- Vol. 4 (4) , 270-272
MSOFA: An Important Step Forward, but Are We Spending Too Much Time on the SOFA?
- 1 December 2010
- Published by Cambridge University Press (CUP) in Disaster Medicine and Public Health Preparedness
- Vol. 4 (4) , 270-272
MSOFA: An Important Step Forward, but Are We Spending Too Much Time on the SOFA?
- 1 October 2010
- Published by Cambridge University Press (CUP) in Disaster Medicine and Public Health Preparedness
- Vol. 4 (3) , 199-206
Mechanical Ventilators in US Acute Care Hospitals
Objective: The supply and distribution of mechanical ventilation capacity is of profound importance for planning for severe public health emergencies. However, the capability of US health systems to provide mechanical ventilation for children and adults remains poorly quantified. The objective of this study was to determine the quantity of adult and pediatric mechanical ventilators at US acute care hospitals.Methods: A total of 5752 US acute care hospitals included in the 2007 American Hospital Association database were surveyed. We measured the quantities of mechanical ventilators and their features.Results: Responding to the survey were 4305 (74.8%) hospitals, which accounted for 83.8% of US intensive care unit beds. Of the 52 118 full-feature mechanical ventilators owned by respondent hospitals, 24 204 (46.4%) are pediatric/neonatal capable. Accounting for nonrespondents, we estimate that there are 62 188 full-feature mechanical ventilators owned by US acute care hospitals. The median number of full-feature mechanical ventilators per 100 000 population for individual states is 19.7 (interquartile ratio 17.2–23.1), ranging from 11.9 to 77.6. The median number of pediatric-capable device full-feature mechanical ventilators per 100 000 population younger than 14 years old is 52.3 (interquartile ratio 43.1–63.9) and the range across states is 22.1 to 206.2. In addition, respondent hospitals reported owning 82 755 ventilators other than full-feature mechanical ventilators; we estimate that there are 98 738 devices other than full-feature ventilators at all of the US acute care hospitals.Conclusions: The number of mechanical ventilators per US population exceeds those reported by other developed countries, but there is wide variation across states in the population-adjusted supply. There are considerably more pediatric-capable ventilators than there are for adults only on a population-adjusted basis.(Disaster Med Public Health Preparedness. 2010;4:199-206)
- 1 October 2010
- Published by Cambridge University Press (CUP) in Disaster Medicine and Public Health Preparedness
- Vol. 4 (3) , 199-206
Mechanical Ventilators in US Acute Care Hospitals
Objective: The supply and distribution of mechanical ventilation capacity is of profound importance for planning for severe public health emergencies. However, the capability of US health systems to provide mechanical ventilation for children and adults remains poorly quantified. The objective of this study was to determine the quantity of adult and pediatric mechanical ventilators at US acute care hospitals.Methods: A total of 5752 US acute care hospitals included in the 2007 American Hospital Association database were surveyed. We measured the quantities of mechanical ventilators and their features.Results: Responding to the survey were 4305 (74.8%) hospitals, which accounted for 83.8% of US intensive care unit beds. Of the 52 118 full-feature mechanical ventilators owned by respondent hospitals, 24 204 (46.4%) are pediatric/neonatal capable. Accounting for nonrespondents, we estimate that there are 62 188 full-feature mechanical ventilators owned by US acute care hospitals. The median number of full-feature mechanical ventilators per 100 000 population for individual states is 19.7 (interquartile ratio 17.2–23.1), ranging from 11.9 to 77.6. The median number of pediatric-capable device full-feature mechanical ventilators per 100 000 population younger than 14 years old is 52.3 (interquartile ratio 43.1–63.9) and the range across states is 22.1 to 206.2. In addition, respondent hospitals reported owning 82 755 ventilators other than full-feature mechanical ventilators; we estimate that there are 98 738 devices other than full-feature ventilators at all of the US acute care hospitals.Conclusions: The number of mechanical ventilators per US population exceeds those reported by other developed countries, but there is wide variation across states in the population-adjusted supply. There are considerably more pediatric-capable ventilators than there are for adults only on a population-adjusted basis.(Disaster Med Public Health Preparedness. 2010;4:199-206)