David L. Hotchkin
Research Subjects
David L. Hotchkin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Carl Rrt Hinkson
Respiratory Care Department, Harborview Medical Center, University of Washington, Seattle, WA, USA
1 shared publication - David J. Pierson
Division of Pulmonary and Critical Care Medicine, Harborview Medical Center, 325 Ninth Avenue, Box 359762, Seattle, WA 98104, USA
1 shared publication - Lewis Rubinson
National Disaster Medical System, 409 C Street, Suite 330, Washington, DC 20224, USA
1 shared publication - Robb W. Glenny
Departments of Medicine and Physiology & Biophysics, University of Washington, Seattle, WA, USA
1 shared publication - Robert P. Dickson
Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, MI USA
1 shared publication - Wayne J. Lamm
Department of Medicine, University of Washington, Seattle, WA, USA
1 shared publication
Latest Publications
- 1 March 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (3) , 527-532
A porcine model for initial surge mechanical ventilator assessment and evaluation of two limited-function ventilators*
Objectives: To adapt an animal model of acute lung injury for use as a standard protocol for a screening initial evaluation of limited function, or “surge,” ventilators for use in mass casualty scenarios. Design: Prospective, experimental animal study. Setting: University research laboratory. Subjects: Twelve adult pigs. Interventions: Twelve spontaneously breathing pigs (six in each group) were subjected to acute lung injury/acute respiratory distress syndrome via pulmonary artery infusion of oleic acid. After development of respiratory failure, animals were mechanically ventilated with a limited-function ventilator (simplified automatic ventilator [SAVe] I or II; Automedx, Germantown, MD) for 1 hr or until the ventilator could not support the animal. The limited-function ventilator was then exchanged for a full-function ventilator (Servo 900C; Siemens-Elema, Solna, Sweden). Measurements and Main Results: Reliable and reproducible levels of acute lung injury/acute respiratory distress syndrome were induced. The SAVe I was unable to adequately oxygenate five animals with Pao2 (52.0 ± 11.1 torr) compared to the Servo (106.0 ± 25.6 torr; p = .002). The SAVe II was able to oxygenate and ventilate all six animals for 1 hr with no difference in Pao2 (141.8 ± 169.3 torr) compared to the Servo (158.3 ± 167.7 torr). Conclusions: We describe a novel in vivo model of acute lung injury/acute respiratory distress syndrome that can be used to initially screen limited-function ventilators considered for mass respiratory failure stockpiles and that is intended to be combined with additional studies to definitively assess appropriateness for mass respiratory failure. Specifically, during this study we demonstrate that the SAVe I ventilator is unable to provide sufficient gas exchange, whereas the SAVe II, with several more functions, was able to support the same level of hypoxemic respiratory failure secondary to acute lung injury/acute respiratory distress syndrome for 1 hr.
- 1 March 2011
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (3) , 527-532
A porcine model for initial surge mechanical ventilator assessment and evaluation of two limited-function ventilators*
Objectives: To adapt an animal model of acute lung injury for use as a standard protocol for a screening initial evaluation of limited function, or “surge,” ventilators for use in mass casualty scenarios. Design: Prospective, experimental animal study. Setting: University research laboratory. Subjects: Twelve adult pigs. Interventions: Twelve spontaneously breathing pigs (six in each group) were subjected to acute lung injury/acute respiratory distress syndrome via pulmonary artery infusion of oleic acid. After development of respiratory failure, animals were mechanically ventilated with a limited-function ventilator (simplified automatic ventilator [SAVe] I or II; Automedx, Germantown, MD) for 1 hr or until the ventilator could not support the animal. The limited-function ventilator was then exchanged for a full-function ventilator (Servo 900C; Siemens-Elema, Solna, Sweden). Measurements and Main Results: Reliable and reproducible levels of acute lung injury/acute respiratory distress syndrome were induced. The SAVe I was unable to adequately oxygenate five animals with Pao2 (52.0 ± 11.1 torr) compared to the Servo (106.0 ± 25.6 torr; p = .002). The SAVe II was able to oxygenate and ventilate all six animals for 1 hr with no difference in Pao2 (141.8 ± 169.3 torr) compared to the Servo (158.3 ± 167.7 torr). Conclusions: We describe a novel in vivo model of acute lung injury/acute respiratory distress syndrome that can be used to initially screen limited-function ventilators considered for mass respiratory failure stockpiles and that is intended to be combined with additional studies to definitively assess appropriateness for mass respiratory failure. Specifically, during this study we demonstrate that the SAVe I ventilator is unable to provide sufficient gas exchange, whereas the SAVe II, with several more functions, was able to support the same level of hypoxemic respiratory failure secondary to acute lung injury/acute respiratory distress syndrome for 1 hr.