Yusa Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yusa Wang has a total of 210 co-authors. Here are the top co-authors by number of shared publications:
- Yupeng Xu
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People’s Republic of China;
11 shared publications - Yong Chen
State Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences
9 shared publications Zijian Zhao
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People’s Republic of China;
8 shared publicationsXiongtao Yang
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People’s Republic of China;
7 shared publications- Yanji Yang
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
7 shared publications Yuxuan Zhu
Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
7 shared publications
Latest Publications
- 1 May 2026
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 138 (5) , 055001
Optical Performance Simulation and Analysis of the Spectroscopy Focusing Array-Timing (SFA-T) X-Ray Telescope onboard the enhanced X-Ray Timing and Polarimetry (eXTP)
The Spectroscopy Focusing Array-Timing (SFA-T) constitutes a principal payload onboard China’s enhanced X-ray Timing and Polarimetry mission (eXTP). To achieve substantial effective area, optimize observational efficiency, and maintain high-precision positioning capabilities, the eXTP mission employs fifty nested Wolter-I mirror shells as its optical architecture across all payloads. Although payload-specific variations exist in coating selection and manufacturing specifications due to differing energy ranges and angular resolution requirements, the fundamental geometric design parameters remain consistent throughout the system. This study presents comprehensive optical simulations of the SFA-T system, which comprises five identical telescope modules. The optical configuration achieves an effective area of 910 cm 2 at 1.50 keV with angular resolution characterized by HPD = 1 ′ and W90 = 3 ′ . Simulations reveal a field of view measuring 18. 4 ′ × 17. 2 ′ and demonstrate that stray light contributes merely 0.1% to central pixel contamination in multi-pixel Silicon Drift Detector, thereby eliminating the requirement for external X-ray baffles. Ground calibration measurements exhibit 29%–43% effective area reduction relative to on-orbit performance due to beam divergence effects. The integrated five-telescope configuration satisfies design specifications for effective area, thereby validating the optical performance for high-precision X-ray timing observations. Furthermore, all these simulation results will play an indispensable role in the calibration implementation and in establishing the on-orbit calibration database for the SFA-T.
- 1 May 2026
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 138 (5) , 055001
Optical Performance Simulation and Analysis of the Spectroscopy Focusing Array-Timing (SFA-T) X-Ray Telescope onboard the enhanced X-Ray Timing and Polarimetry (eXTP)
The Spectroscopy Focusing Array-Timing (SFA-T) constitutes a principal payload onboard China’s enhanced X-ray Timing and Polarimetry mission (eXTP). To achieve substantial effective area, optimize observational efficiency, and maintain high-precision positioning capabilities, the eXTP mission employs fifty nested Wolter-I mirror shells as its optical architecture across all payloads. Although payload-specific variations exist in coating selection and manufacturing specifications due to differing energy ranges and angular resolution requirements, the fundamental geometric design parameters remain consistent throughout the system. This study presents comprehensive optical simulations of the SFA-T system, which comprises five identical telescope modules. The optical configuration achieves an effective area of 910 cm 2 at 1.50 keV with angular resolution characterized by HPD = 1 ′ and W90 = 3 ′ . Simulations reveal a field of view measuring 18. 4 ′ × 17. 2 ′ and demonstrate that stray light contributes merely 0.1% to central pixel contamination in multi-pixel Silicon Drift Detector, thereby eliminating the requirement for external X-ray baffles. Ground calibration measurements exhibit 29%–43% effective area reduction relative to on-orbit performance due to beam divergence effects. The integrated five-telescope configuration satisfies design specifications for effective area, thereby validating the optical performance for high-precision X-ray timing observations. Furthermore, all these simulation results will play an indispensable role in the calibration implementation and in establishing the on-orbit calibration database for the SFA-T.
- Open Access
- 1 December 2025
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 137 (12) , 125001
Cross-calibration of an eXTP Mirror Prototype at 100XF and PANTER
The enhanced X-ray Timing and Polarimetry (eXTP) mission is China’s future flagship X-ray astronomy observatory. The eXTP payload comprises an array of Wolter-I focusing mirrors that utilize nickel electroforming technology. The testing and calibration of the eXTP mirror assemblies will be primarily conducted at the 100 m X-ray Test Facility (100XF) at the Institute of High Energy Physics, with support from the PANTER facility of the Max Planck Institute for Extraterrestrial Physics. Consequently, cross-calibration between the facilities is essential. This paper presents preliminary cross-calibration for mirror module 3 of the eXTP focusing mirror, conducted at both the 100XF and PANTER facilities, focusing on point spread functions (PSFs), vignetting, and effective area. The angular resolutions obtained at the two facilities are 21 . ″ 8 ± 0 . ″ 2@Al–K α , 29 . ″ 8 ± 0 . ″ 5@Cu–K α (100XF), as well as 21 . ″ 9 ± 0 . ″ 2@Al–K α , 27 . ″ 6 ± 0 . ″ 5@Cu–K α (PANTER). The measured effective area results at 100XF are 52.0 ± 0.7 cm 2 @Al–K α , 12.1 ± 0.1 cm 2 @Cu–K α . Meanwhile, after correcting for beam length (or divergence angle), the results from PANTER are 52.8 ± 0.7 cm 2 @Al–K α , 12.2 ± 0.2 cm 2 @Cu–K α . The cross-calibration results validate the reliability of the calibration methodologies for eXTP mirrors. Consistent outcomes in alignment, focus search, and PSFs were achieved, satisfying stringent mission requirements. Effective area measurements showed good agreement with simulations, with deviations limited to ±10%. These cross-calibration results provide valuable references for subsequent mirror calibrations and corrections, especially concerning effective area calibration, which should be a key focus of future research efforts.
- 1 December 2025
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 137 (12) , 125001
Open AccessCross-calibration of an eXTP Mirror Prototype at 100XF and PANTER
The enhanced X-ray Timing and Polarimetry (eXTP) mission is China’s future flagship X-ray astronomy observatory. The eXTP payload comprises an array of Wolter-I focusing mirrors that utilize nickel electroforming technology. The testing and calibration of the eXTP mirror assemblies will be primarily conducted at the 100 m X-ray Test Facility (100XF) at the Institute of High Energy Physics, with support from the PANTER facility of the Max Planck Institute for Extraterrestrial Physics. Consequently, cross-calibration between the facilities is essential. This paper presents preliminary cross-calibration for mirror module 3 of the eXTP focusing mirror, conducted at both the 100XF and PANTER facilities, focusing on point spread functions (PSFs), vignetting, and effective area. The angular resolutions obtained at the two facilities are 21 . ″ 8 ± 0 . ″ 2@Al–K α , 29 . ″ 8 ± 0 . ″ 5@Cu–K α (100XF), as well as 21 . ″ 9 ± 0 . ″ 2@Al–K α , 27 . ″ 6 ± 0 . ″ 5@Cu–K α (PANTER). The measured effective area results at 100XF are 52.0 ± 0.7 cm 2 @Al–K α , 12.1 ± 0.1 cm 2 @Cu–K α . Meanwhile, after correcting for beam length (or divergence angle), the results from PANTER are 52.8 ± 0.7 cm 2 @Al–K α , 12.2 ± 0.2 cm 2 @Cu–K α . The cross-calibration results validate the reliability of the calibration methodologies for eXTP mirrors. Consistent outcomes in alignment, focus search, and PSFs were achieved, satisfying stringent mission requirements. Effective area measurements showed good agreement with simulations, with deviations limited to ±10%. These cross-calibration results provide valuable references for subsequent mirror calibrations and corrections, especially concerning effective area calibration, which should be a key focus of future research efforts.
- 11 June 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (2) , 324-334
Design and in-orbit performance of EP-FXT thermal control
- 11 June 2025
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 9 (2) , 324-334
Design and in-orbit performance of EP-FXT thermal control
- 8 May 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 59 (3) , 1-14
Pre-flight calibration of the optics assembly for CATCH’s first pathfinder
- 8 May 2025
- Published by Springer Nature in Experimental Astronomy
- Vol. 59 (3) , 1-14
Pre-flight calibration of the optics assembly for CATCH’s first pathfinder
- Open Access
- 1 April 2025
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 137 (4) , 045001
An X-Ray Optic System Ray-tracing Package for FXT on Board EP Satellite
The Einstein Probe (EP) mission, launched in 2024 January, is a time-domain X-ray satellite designed to discover and study X-ray transient and burst sources while investigating electromagnetic counterparts to gravitational waves. To achieve precise observations, EP features the Follow-up X-ray Telescope (FXT), equipped with two Wolter-I type mirrors for precise imaging within a 1 square degree field of view. A specialized Ray-Tracing package for the FXT (RTF) was developed to assess the Wolter-I type mirrors’ performance used in FXT. By employing specialized algorithms to simulate X-ray photon total reflection, RTF has yielded valuable insights into key optical parameters such as point-spread function, effective area, and vignetting. The package also evaluates components like the X-ray baffle and filter wheel, further enhancing the optical system’s efficacy. Moreover, the ray-tracing results have been validated against measurements. These simulations are crucial for ground calibration and will assist in maximizing the scientific output of the EP mission by improving the understanding of mirrors’ behavior in various observational conditions.
- 1 April 2025
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 137 (4) , 045001
Open AccessAn X-Ray Optic System Ray-tracing Package for FXT on Board EP Satellite
The Einstein Probe (EP) mission, launched in 2024 January, is a time-domain X-ray satellite designed to discover and study X-ray transient and burst sources while investigating electromagnetic counterparts to gravitational waves. To achieve precise observations, EP features the Follow-up X-ray Telescope (FXT), equipped with two Wolter-I type mirrors for precise imaging within a 1 square degree field of view. A specialized Ray-Tracing package for the FXT (RTF) was developed to assess the Wolter-I type mirrors’ performance used in FXT. By employing specialized algorithms to simulate X-ray photon total reflection, RTF has yielded valuable insights into key optical parameters such as point-spread function, effective area, and vignetting. The package also evaluates components like the X-ray baffle and filter wheel, further enhancing the optical system’s efficacy. Moreover, the ray-tracing results have been validated against measurements. These simulations are crucial for ground calibration and will assist in maximizing the scientific output of the EP mission by improving the understanding of mirrors’ behavior in various observational conditions.
- 1 November 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 58 (3) , 1-17
Reflectivity test method of x-ray optics at the 100-m x-ray test facility
- 1 November 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 58 (3) , 1-17
Reflectivity test method of x-ray optics at the 100-m x-ray test facility
- 13 October 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 58 (2) , 1-20
A thermo-optical test device utilizing the 100-m x-ray test facility
- 13 October 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 58 (2) , 1-20
A thermo-optical test device utilizing the 100-m x-ray test facility
- 14 June 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (3) , 1-14
Spectral and timing calibration of eXTP-SFA engineering model in 100XF
- 14 June 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (3) , 1-14
Spectral and timing calibration of eXTP-SFA engineering model in 100XF
- 14 June 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (3) , 1-15
Characterization of the eXTP-LAD collimators
- 14 June 2024
- Published by Springer Nature in Experimental Astronomy
- Vol. 57 (3) , 1-15
Characterization of the eXTP-LAD collimators