YYYanji Yang

Yanji Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yanji Yang has a total of 132 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optical Performance Simulation and Analysis of the Spectroscopy Focusing Array-Timing (SFA-T) X-Ray Telescope onboard the enhanced X-Ray Timing and Polarimetry (eXTP)

    by Yuxuan Zhu, Yusa Wang, Yanji Yang, Wei Li, Zhenjie Li, Jia Ma, Qiong Wu, Laidan Luo, Zijian Zhao, Xiongtao Yang, et al.

    The Spectroscopy Focusing Array-Timing (SFA-T) constitutes a principal payload onboard China’s enhanced X-ray Timing and Polarimetry mission (eXTP). To achieve substantial effective area, optimize observational efficiency, and maintain high-precision positioning capabilities, the eXTP mission employs fifty nested Wolter-I mirror shells as its optical architecture across all payloads. Although payload-specific variations exist in coating selection and manufacturing specifications due to differing energy ranges and angular resolution requirements, the fundamental geometric design parameters remain consistent throughout the system. This study presents comprehensive optical simulations of the SFA-T system, which comprises five identical telescope modules. The optical configuration achieves an effective area of 910 cm 2 at 1.50 keV with angular resolution characterized by HPD = 1 ′ and W90 = 3 ′ . Simulations reveal a field of view measuring 18. 4 ′ × 17. 2 ′ and demonstrate that stray light contributes merely 0.1% to central pixel contamination in multi-pixel Silicon Drift Detector, thereby eliminating the requirement for external X-ray baffles. Ground calibration measurements exhibit 29%–43% effective area reduction relative to on-orbit performance due to beam divergence effects. The integrated five-telescope configuration satisfies design specifications for effective area, thereby validating the optical performance for high-precision X-ray timing observations. Furthermore, all these simulation results will play an indispensable role in the calibration implementation and in establishing the on-orbit calibration database for the SFA-T.


  • Open Access

    Cross-calibration of an eXTP Mirror Prototype at 100XF and PANTER

    by Yuxuan Zhu, Vadim Burwitz, Dongjie Hou, Yifan Zhang, Zijian Zhao, Xiongtao Yang, Yanji Yang, Dong Xie, Jia Ma, Yusa Wang, et al.

    The enhanced X-ray Timing and Polarimetry (eXTP) mission is China’s future flagship X-ray astronomy observatory. The eXTP payload comprises an array of Wolter-I focusing mirrors that utilize nickel electroforming technology. The testing and calibration of the eXTP mirror assemblies will be primarily conducted at the 100 m X-ray Test Facility (100XF) at the Institute of High Energy Physics, with support from the PANTER facility of the Max Planck Institute for Extraterrestrial Physics. Consequently, cross-calibration between the facilities is essential. This paper presents preliminary cross-calibration for mirror module 3 of the eXTP focusing mirror, conducted at both the 100XF and PANTER facilities, focusing on point spread functions (PSFs), vignetting, and effective area. The angular resolutions obtained at the two facilities are 21 . ″ 8 ± 0 . ″ 2@Al–K α , 29 . ″ 8 ± 0 . ″ 5@Cu–K α (100XF), as well as 21 . ″ 9 ± 0 . ″ 2@Al–K α , 27 . ″ 6 ± 0 . ″ 5@Cu–K α (PANTER). The measured effective area results at 100XF are 52.0 ± 0.7 cm 2 @Al–K α , 12.1 ± 0.1 cm 2 @Cu–K α . Meanwhile, after correcting for beam length (or divergence angle), the results from PANTER are 52.8 ± 0.7 cm 2 @Al–K α , 12.2 ± 0.2 cm 2 @Cu–K α . The cross-calibration results validate the reliability of the calibration methodologies for eXTP mirrors. Consistent outcomes in alignment, focus search, and PSFs were achieved, satisfying stringent mission requirements. Effective area measurements showed good agreement with simulations, with deviations limited to ±10%. These cross-calibration results provide valuable references for subsequent mirror calibrations and corrections, especially concerning effective area calibration, which should be a key focus of future research efforts.


  • Development of Wolter I X-ray focusing mirror using the nickel replica in IHEP

    by Yang Yanji, Yu Ke, Wang Juan, Ma Jia, Tian Jinxin, Li Xin, Zhang Qian, Bi Xiyan, Wang Bo, Wang Dianlong, et al.


  • Design and in-orbit performance of EP-FXT thermal control

    by Jia Ma, Yusa Wang, Jianchao Feng, Qingjun Tang, Peter Friedrich, Josef Eder, Juan Wang, Yanji Yang, Weiwei Cui, Xiongtao Yang, et al.

  • Numerical dynamical analysis of two types of X-ray baffles onboard EP-FXT mirror assembly

    by Bing Lu, Juan Wang, Yanji Yang, Dawei Han, Weiwei Cui, Yusa Wang, Jia Ma, Aimei Zhang, Sheng Yang, Ruijie Wang, et al.

  • Influence analysis of surface particulate and molecular contamination in CMP process of mandrel for EP focusing mirror

    by Jiadai Xue, Yunke Chu, Yutao Liu, Qiuyan Liao, Wentao Chen, Yangong Wu, Fei Ding, Bo Wang, Guo Li, Dianlong Wang, et al.


  • Open Access

    An X-Ray Optic System Ray-tracing Package for FXT on Board EP Satellite

    by Yuxuan Zhu, Yanji Yang, Xiaofan Zhao, Wang Juan, Tianxiang Chen, Yusa Wang, Weiwei Cui, Wei Li, Dawei Han, Peter Friedrich, et al.

    The Einstein Probe (EP) mission, launched in 2024 January, is a time-domain X-ray satellite designed to discover and study X-ray transient and burst sources while investigating electromagnetic counterparts to gravitational waves. To achieve precise observations, EP features the Follow-up X-ray Telescope (FXT), equipped with two Wolter-I type mirrors for precise imaging within a 1 square degree field of view. A specialized Ray-Tracing package for the FXT (RTF) was developed to assess the Wolter-I type mirrors’ performance used in FXT. By employing specialized algorithms to simulate X-ray photon total reflection, RTF has yielded valuable insights into key optical parameters such as point-spread function, effective area, and vignetting. The package also evaluates components like the X-ray baffle and filter wheel, further enhancing the optical system’s efficacy. Moreover, the ray-tracing results have been validated against measurements. These simulations are crucial for ground calibration and will assist in maximizing the scientific output of the EP mission by improving the understanding of mirrors’ behavior in various observational conditions.


  • Reflectivity test method of x-ray optics at the 100-m x-ray test facility

    by Yuxuan Zhu, Zijian Zhao, Dongjie Hou, Yanji Yang, Xiongtao Yang, Yifan Zhang, Kaiji Wu, Fei Ding, Dong Xie, Yupeng Xu, et al.


  • Open Access

    Precision Manufacturing in China of Replication Mandrels for Ni-Based Monolithic Wolter-I X-ray Mirror Mandrels

    by Jiadai Xue, Bo Wang, Qiuyan Liao, Kaiji Wu, Yutao Liu, Yangong Wu, Wentao Chen, Zheng Qiao, Yuan Jin, Fei Ding, et al.

    The X-ray satellite “Einstein Probe” of the Chinese Academy of Sciences (CAS) was successfully launched on 9 January 2024 at 15:03 Beijing Time from the Xichang Satellite Launch Center in China with a “Long March-2C” rocket. The Einstein Probe is equipped with two scientific X-ray telescopes. One is the Wide-field X-ray Telescope (WXT), which uses lobster-eye optics. The other is the Follow-up X-ray Telescope (FXT), a Wolter-I type telescope. These telescopes are designed to study the universe for high-energy X-rays associated with transient high-energy phenomena. The FXT consists of two modules based on 54 thin X-ray Wolter-I grazing incidence Ni-replicated mirrors produced by the Italian Media Lario company, as contributions from the European Space Agency and the Max Planck Institute for Extraterrestrial Physics (MPE), which also provided the focal-plane detectors. Meanwhile, the Institute of High Energy Physics (IHEP), together with the Harbin Institute of Technology and Xi’an Institute of Optics and Precision Mechanics, has also completed the development and production of the structural and thermal model (STM), qualification model (QM) and flight model (FM) of FXT mirrors for the Einstein Probe (EP) satellites for demonstration purposes. This paper introduces the precision manufacturing adopted in China of Wolter-I X-ray mirror mandrels similar to those used for the EP-FXT payload. Moreover, the adopted electroformed nickel replication process, based on a chemical nickel–phosphorus alloy, is reported. The final results show that the surface of the produced mandrels after demolding and the internal surface of the mirrors have been super polished to the roughness level better than 0.3 nm RMS and the surface accuracy is better than 0.2 μm, and the mirror angular resolution for single mirror shells may be as good as 17.3 arcsec HPD (Half Power Diameter), 198 arcsec W90 (90% Energy Width) @1.49 keV (Al-K line). These results demonstrate the reliability and advancement of the process. As the first efficient X-ray-focusing optics manufacturing chain established in China, we successfully developed the first focusing mirror prototype that could be used for future X-ray satellite payloads.


  • A thermo-optical test device utilizing the 100-m x-ray test facility

    by Jia Ma, Yusa Wang, Zijian Zhao, Dongjie Hou, Juan Wang, Xiongtao Yang, Yuxuan Zhu, Jianchao Feng, Xiaofan Zhao, Weiwei Cui, et al.