KTKeiko Tsuchiya

Keiko Tsuchiya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Keiko Tsuchiya has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Value of breast MRI for patients with a biopsy showing atypical ductal hyperplasia (ADH)

    by Keiko Tsuchiya, Naoko Mori, David V. Schacht, Deepa Sheth, Gregory S. Karczmar, Gillian M. Newstead, Hiroyuki Abe

    Purpose To evaluate the diagnostic value of dynamic contrast‐enhanced (DCE) magnetic resonance imaging (MRI) for patients with atypical ductal hyperplasia (ADH) in predicting malignant upgrade. Materials and Methods 3T DCE‐MRI was performed for 17 patients with ADH (median age 52, range 42–76) proven by stereotactic biopsy (n = 15), and ultrasound‐guided biopsy (n = 2) from January 2011 to April 2015. All patients underwent surgical excision after the MRI. Two radiologists prospectively reviewed the MRI to determine the presence or absence of suspicious findings at the site of biopsy, and evaluated the MR features of any lesion present according to the Breast Imaging Reporting and Data System (BI‐RADS) lexicon. MRI findings and clinical information were correlated with the final surgical pathology by multivariate analysis. Results Nine of 17 lesions were upgraded to malignancy. MRI demonstrated suspicious nonmass enhancement (NME) at the site of biopsy in all upgraded patients. The median size was 19.5 mm (range, 9–44 mm). In the eight patients without upgrade, no enhancement (n = 2), linear enhancement along the biopsy track (n = 4), thin rim enhancement around hematoma (n = 1), and a focal NME (n = 1) were seen. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MRI findings were 100, 87.5, 90, and 100%, respectively. Multivariate analysis revealed that the presence of suspicious enhancement on MRI was the most significant predictor of upgrade to malignancy (P = 0.0006) Conclusion Our study revealed a high NPV of DCE‐MRI for patients with ADH in terms of malignant upgrade at subsequent surgery. This suggests that patients with ADH without suspicious enhancement on DCE‐MRI might be followed with DCE‐MRI rather than undergoing surgical excision. Level of Evidence: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1738–1747.


  • A phantom study for ground-glass nodule detectability using chest digital tomosynthesis with iterative reconstruction algorithm by ten observers: association with radiation dose and nodular characteristics

    by Katsunori Miyata, Yukihiro Nagatani, Mitsuru Ikeda, Masashi Takahashi, Norihisa Nitta, Satoru Matsuo, Shinichi Ohta, Hideji Otani, Ayumi Nitta-Seko, Yoko Murakami, et al.

    Objective: To compare detectability of simulated ground-glass nodules (GGNs) on chest digital tomosynthesis (CDT) among 12 images obtained at 6 radiation doses using 2 reconstruction algorithms and to analyze its association with nodular size and density. Methods: 74 simulated GGNs [5, 8 and 10 mm in diameter/−630 and −800 Hounsfield units (HU) in density] were placed in a chest phantom in 14 nodular distribution patterns. 12 sets of coronal images were obtained using CDT at 6 radiation doses: 120 kV–10 mA/20 mA/80 mA/160 mA, 100 kV–80 mA and 80 kV–320 mA with and without iterative reconstruction (IR). 10 radiologists recorded GGN presence and locations by continuously distributed rating. GGN detectability was compared by receiver operating characteristic analysis among 12 images and detection sensitivities (DS) were compared among 12 images in subgroups classified by nodular diameters and densities. Results: GGN detectability at 120 kV–160 mA with IR was similar to that at 120 kV–80 mA with IR (0.614 mSv), as area under receiver operating characteristic curve was 0.798 ± 0.024 and 0.788 ± 0.025, respectively, and higher than six images acquired at 120 kV (p < 0.05). For nodules of −630 HU/8 mm, DS at 120 kV–10 mA without IR was 73.5 ± 6.0% and was similar to that by the other 11 data acquisition methods (p = 0.157). For nodules of −800 HU/10 mm, DS both at 120 kV–80 mA and 120 kV–160 mA without IR was improved by IR (56.3 ± 11.9%) (p < 0.05). Conclusion: CDT demonstrated sufficient detectability for larger more-attenuated GGNs (>8 mm) even in the lowest radiation dose (0.17 mSv) and improved detectability for less-attenuated GGNs with the diameter of 10 mm at submillisievert with IR. Advances in knowledge: IR improved detectability for larger less-attenuated simulated GGNs on CDT.


  • MRI study of atherosclerotic plaque progression using ultrasmall superparamagnetic iron oxide in Watanabe heritable hyperlipidemic rabbits

    by C Kaneko, N Nitta, K Tsuchiya, S Watanabe, A Nitta-Seko, S Ohta, H Otani, A Sonoda, K Murata, M Shiomi

    The purpose of this study was to evaluate plaque progression by using MRI with ultrasmall superparamagnetic iron oxide (USPIO) and by histopathological studies. We divided 12 Watanabe heritable hyperlipidemic (WHHL) rabbits into 4 groups based on their age (3, 9, 14 and 26 months) and injected them intravenously with 0.8 mmol (Fe) kg(-1) of USPIO (size, 32 nm; concentration, 15 mg dl(-1)). On the fifth post-injection day, they were again given an intravenous injection with 40 μmol kg(-1) of the same USPIO, and MR angiography (MRA) was performed. The signal-to-noise ratio (SNR) in regions of interest in the wall of the upper abdominal aorta was calculated on coronal images. Specimens from the same level of the aorta were subjected to iron staining and RAM-11 immunostaining and used for histopathological study. For statistical analysis of the MRA and histopathological findings, we used analysis of variance [Tukey's honest significant difference (HSD) test]. In 9-month-old rabbits, the SNR was significantly lower than in rabbits of the other ages (p < 0.01), and the area of RAM-11 (DAKO Corporation, Glostrup, Denmark) and iron uptake in the aortic wall was significantly larger (RAM-11, p < 0.01; iron, p < 0.05). These areas were the smallest in 3-month-old rabbits. Histopathologically, the number of macrophages was the greatest in 9-month-old rabbits. Our findings indicate that the SNR on MRI scans reflects the number of macrophages in the aortic wall of WHHL rabbits. USPIO-enhanced MRI visualized the accumulation of macrophages in early atherosclerotic plaques of WHHL rabbits in the course of natural progression.


  • Negatively charged superparamagnetic iron oxide nanoparticles: a new blood-pooling magnetic resonance contrast agent

    by Norihisa Nitta, Keiko Tsuchiya, Akinaga Sonoda, Shinichi Ota, Noritoshi Ushio, Masashi Takahashi, Kiyoshi Murata, Satoshi Nohara

    Our purpose was to investigate the utility of superparamagnetic iron-oxide nanoparticles (SPIO) as a blood-pooling contrast agent at magnetic resonance imaging (MRI). We studied four contrast agents: carboxymethyl-diethylaminoethyl dextran magnetite SPIO (CMEADM-S, diameter 54 nm), negatively charged CMEADM ultrasmall SPIO (CMEADM-U, 32 nm), alkali-treated dextran magnetite SPIO (ATDM-S, 55 nm), and ATDM ultrasmall SPIO (ATDM-U, 28 nm) carrying a neutral charge. Each contrast agent (80 μmol/kg) was injected intraperitoneally into apolipoprotein E (apoE) mice and the tissue iron concentration was measured 30-, 60-, 180-, and 300-min later by nuclear MR. For MR angiographic (MRA) evaluation, we injected the agents into the auricular vein of four groups of 15 rabbits. Immediately and 30-, 60-, 180-, and 300-min later, three rabbits from each group were subjected to MRI. The organ/background signal ratio (SR) was calculated. Statistical analyses were performed with Tukey’s honestly significant difference (HSD) test. At 60 and 180 min, blood-iron concentration of CMEADM-U was significantly different from other contrast agents. In the abdominal aorta and inferior vena cava, SR of CMEADM-U was higher at 180 and 300 min than of the other contrast agents. In the thoracic aorta, there was no difference in SR at 300 min between CMEADM-U and CMEADM-S. Negatively charged SPIO nanoparticles may be useful as a blood-pooling contrast agent.


  • Comparison of the Anti-tumor Effects of Two Platinum Agents (Miriplatin and Fine-Powder Cisplatin)

    by Shobu Watanabe, Norihisa Nitta, Shinichi Ohta, Akinaga Sonoda, Hideji Otani, Yuki Tomozawa, Ayumi Nitta-Seko, Keiko Tsuchiya, Toyohiko Tanka, Masashi Takahashi, et al.

    This study was designed to evaluate the anti-tumor effects of miriplatin-lipidol and fine-powder cisplatin–lipiodol suspensions. Assessment of the cytotoxicity of two drugs was performed: a soluble derivative of miriplatin (DPC) and fine-powder cisplatin. We randomly divided 15 rabbits with transplanted VX2 liver tumors into three equal groups. They were infused via the proper hepatic artery with a miriplatin-lipiodol suspension (ML), a fine-powder cisplatin-lipiodol suspension (CL), or saline (control) and the tumor growth rate was determined on MR images acquired before and 7 days after treatment. The concentration of platinum (PCs) in blood was assayed immediately, and 10, 30, and 60 min, and 24 h and 7 days after drug administration. Its concentration in tumor and surrounding normal liver tissues was determined at 7 days postadministration. At high concentrations, fine-powder cisplatin exhibited stronger cytotoxicity than DPC. At low concentrations, both agents manifested weak cytotoxicity. While there was no difference between the tumor growth rate of the ML and the CL groups, the difference between the controls and ML- and CL-treated rabbits was significant. The blood PCs peaked at 10 min and then gradually decreased over time. On the other hand, no platinum was detected at any point after the administration of ML. There was no difference between the ML and CL groups in the PCs in tumor tissues; however, in normal hepatic tissue, the PCs were higher in ML- than CL-treated rabbits. We confirmed the anti-tumor effect of ML and CL. There was no significant difference between the anti-tumor effect of ML and CL at 7 days postadministration.