Shinichi Ohta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shinichi Ohta has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Kiyoshi Murata
Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan
4 shared publications - Masashi Takahashi
Shiga University of Medical Science
4 shared publications Akinaga Sonoda
Shiga University of Medical Science
3 shared publications- Keiko Tsuchiya
Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan
3 shared publications Kiyoshi Murata
Shiga University of Medical Science
3 shared publicationsMasashi Takahashi
Shiga University of Medical Science
3 shared publications
Latest Publications
- 17 February 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1071) , 20160555
A phantom study for ground-glass nodule detectability using chest digital tomosynthesis with iterative reconstruction algorithm by ten observers: association with radiation dose and nodular characteristics
Objective: To compare detectability of simulated ground-glass nodules (GGNs) on chest digital tomosynthesis (CDT) among 12 images obtained at 6 radiation doses using 2 reconstruction algorithms and to analyze its association with nodular size and density. Methods: 74 simulated GGNs [5, 8 and 10 mm in diameter/−630 and −800 Hounsfield units (HU) in density] were placed in a chest phantom in 14 nodular distribution patterns. 12 sets of coronal images were obtained using CDT at 6 radiation doses: 120 kV–10 mA/20 mA/80 mA/160 mA, 100 kV–80 mA and 80 kV–320 mA with and without iterative reconstruction (IR). 10 radiologists recorded GGN presence and locations by continuously distributed rating. GGN detectability was compared by receiver operating characteristic analysis among 12 images and detection sensitivities (DS) were compared among 12 images in subgroups classified by nodular diameters and densities. Results: GGN detectability at 120 kV–160 mA with IR was similar to that at 120 kV–80 mA with IR (0.614 mSv), as area under receiver operating characteristic curve was 0.798 ± 0.024 and 0.788 ± 0.025, respectively, and higher than six images acquired at 120 kV (p < 0.05). For nodules of −630 HU/8 mm, DS at 120 kV–10 mA without IR was 73.5 ± 6.0% and was similar to that by the other 11 data acquisition methods (p = 0.157). For nodules of −800 HU/10 mm, DS both at 120 kV–80 mA and 120 kV–160 mA without IR was improved by IR (56.3 ± 11.9%) (p < 0.05). Conclusion: CDT demonstrated sufficient detectability for larger more-attenuated GGNs (>8 mm) even in the lowest radiation dose (0.17 mSv) and improved detectability for less-attenuated GGNs with the diameter of 10 mm at submillisievert with IR. Advances in knowledge: IR improved detectability for larger less-attenuated simulated GGNs on CDT.
- 17 February 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1071) , 20160555
A phantom study for ground-glass nodule detectability using chest digital tomosynthesis with iterative reconstruction algorithm by ten observers: association with radiation dose and nodular characteristics
Objective: To compare detectability of simulated ground-glass nodules (GGNs) on chest digital tomosynthesis (CDT) among 12 images obtained at 6 radiation doses using 2 reconstruction algorithms and to analyze its association with nodular size and density. Methods: 74 simulated GGNs [5, 8 and 10 mm in diameter/−630 and −800 Hounsfield units (HU) in density] were placed in a chest phantom in 14 nodular distribution patterns. 12 sets of coronal images were obtained using CDT at 6 radiation doses: 120 kV–10 mA/20 mA/80 mA/160 mA, 100 kV–80 mA and 80 kV–320 mA with and without iterative reconstruction (IR). 10 radiologists recorded GGN presence and locations by continuously distributed rating. GGN detectability was compared by receiver operating characteristic analysis among 12 images and detection sensitivities (DS) were compared among 12 images in subgroups classified by nodular diameters and densities. Results: GGN detectability at 120 kV–160 mA with IR was similar to that at 120 kV–80 mA with IR (0.614 mSv), as area under receiver operating characteristic curve was 0.798 ± 0.024 and 0.788 ± 0.025, respectively, and higher than six images acquired at 120 kV (p < 0.05). For nodules of −630 HU/8 mm, DS at 120 kV–10 mA without IR was 73.5 ± 6.0% and was similar to that by the other 11 data acquisition methods (p = 0.157). For nodules of −800 HU/10 mm, DS both at 120 kV–80 mA and 120 kV–160 mA without IR was improved by IR (56.3 ± 11.9%) (p < 0.05). Conclusion: CDT demonstrated sufficient detectability for larger more-attenuated GGNs (>8 mm) even in the lowest radiation dose (0.17 mSv) and improved detectability for less-attenuated GGNs with the diameter of 10 mm at submillisievert with IR. Advances in knowledge: IR improved detectability for larger less-attenuated simulated GGNs on CDT.
- Open Access
- 17 October 2014
- Published by Springer Nature in SpringerPlus
- Vol. 3 (1) , 607
Imaging findings of primary hepatic carcinoid tumor with an emphasis on MR imaging: case study
Carcinoid tumors are slow-growing tumors originating in the neuroendocrine cells, and occur most frequently within the gastrointestinal tract. Although the liver is the most common site for metastatic carcinoid tumors, primary hepatic carcinoid tumors are exceedingly rare and reports of the imaging findings have been very scarce. We herein report imaging findings with an emphasis on magnetic resonance imaging in two cases of primary hepatic carcinoid tumors. In both cases, the tumors showed cystic areas with hemorrhagic components and early enhanced solid areas.
- 17 October 2014
- Published by Springer Nature in SpringerPlus
- Vol. 3 (1) , 607
Open AccessImaging findings of primary hepatic carcinoid tumor with an emphasis on MR imaging: case study
Carcinoid tumors are slow-growing tumors originating in the neuroendocrine cells, and occur most frequently within the gastrointestinal tract. Although the liver is the most common site for metastatic carcinoid tumors, primary hepatic carcinoid tumors are exceedingly rare and reports of the imaging findings have been very scarce. We herein report imaging findings with an emphasis on magnetic resonance imaging in two cases of primary hepatic carcinoid tumors. In both cases, the tumors showed cystic areas with hemorrhagic components and early enhanced solid areas.
- 13 December 2012
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (4) , 1105-1111
Gelatin Microspheres: Correlation between Embolic Effect/Degradability and Cross-linkage/Particle Size
To evaluate the embolic effect and degradability of gelatin microspheres (GMS) using various degrees of cross-linkage and particle sizes in rabbit renal artery embolization.
- 13 December 2012
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (4) , 1105-1111
Gelatin Microspheres: Correlation between Embolic Effect/Degradability and Cross-linkage/Particle Size
To evaluate the embolic effect and degradability of gelatin microspheres (GMS) using various degrees of cross-linkage and particle sizes in rabbit renal artery embolization.
- 22 September 2012
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 30 (10) , 832-839
Negatively charged superparamagnetic iron oxide nanoparticles: a new blood-pooling magnetic resonance contrast agent
Our purpose was to investigate the utility of superparamagnetic iron-oxide nanoparticles (SPIO) as a blood-pooling contrast agent at magnetic resonance imaging (MRI). We studied four contrast agents: carboxymethyl-diethylaminoethyl dextran magnetite SPIO (CMEADM-S, diameter 54 nm), negatively charged CMEADM ultrasmall SPIO (CMEADM-U, 32 nm), alkali-treated dextran magnetite SPIO (ATDM-S, 55 nm), and ATDM ultrasmall SPIO (ATDM-U, 28 nm) carrying a neutral charge. Each contrast agent (80 μmol/kg) was injected intraperitoneally into apolipoprotein E (apoE) mice and the tissue iron concentration was measured 30-, 60-, 180-, and 300-min later by nuclear MR. For MR angiographic (MRA) evaluation, we injected the agents into the auricular vein of four groups of 15 rabbits. Immediately and 30-, 60-, 180-, and 300-min later, three rabbits from each group were subjected to MRI. The organ/background signal ratio (SR) was calculated. Statistical analyses were performed with Tukey’s honestly significant difference (HSD) test. At 60 and 180 min, blood-iron concentration of CMEADM-U was significantly different from other contrast agents. In the abdominal aorta and inferior vena cava, SR of CMEADM-U was higher at 180 and 300 min than of the other contrast agents. In the thoracic aorta, there was no difference in SR at 300 min between CMEADM-U and CMEADM-S. Negatively charged SPIO nanoparticles may be useful as a blood-pooling contrast agent.
- 22 September 2012
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 30 (10) , 832-839
Negatively charged superparamagnetic iron oxide nanoparticles: a new blood-pooling magnetic resonance contrast agent
Our purpose was to investigate the utility of superparamagnetic iron-oxide nanoparticles (SPIO) as a blood-pooling contrast agent at magnetic resonance imaging (MRI). We studied four contrast agents: carboxymethyl-diethylaminoethyl dextran magnetite SPIO (CMEADM-S, diameter 54 nm), negatively charged CMEADM ultrasmall SPIO (CMEADM-U, 32 nm), alkali-treated dextran magnetite SPIO (ATDM-S, 55 nm), and ATDM ultrasmall SPIO (ATDM-U, 28 nm) carrying a neutral charge. Each contrast agent (80 μmol/kg) was injected intraperitoneally into apolipoprotein E (apoE) mice and the tissue iron concentration was measured 30-, 60-, 180-, and 300-min later by nuclear MR. For MR angiographic (MRA) evaluation, we injected the agents into the auricular vein of four groups of 15 rabbits. Immediately and 30-, 60-, 180-, and 300-min later, three rabbits from each group were subjected to MRI. The organ/background signal ratio (SR) was calculated. Statistical analyses were performed with Tukey’s honestly significant difference (HSD) test. At 60 and 180 min, blood-iron concentration of CMEADM-U was significantly different from other contrast agents. In the abdominal aorta and inferior vena cava, SR of CMEADM-U was higher at 180 and 300 min than of the other contrast agents. In the thoracic aorta, there was no difference in SR at 300 min between CMEADM-U and CMEADM-S. Negatively charged SPIO nanoparticles may be useful as a blood-pooling contrast agent.
- 17 May 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 35 (2) , 399-405
Comparison of the Anti-tumor Effects of Two Platinum Agents (Miriplatin and Fine-Powder Cisplatin)
This study was designed to evaluate the anti-tumor effects of miriplatin-lipidol and fine-powder cisplatin–lipiodol suspensions. Assessment of the cytotoxicity of two drugs was performed: a soluble derivative of miriplatin (DPC) and fine-powder cisplatin. We randomly divided 15 rabbits with transplanted VX2 liver tumors into three equal groups. They were infused via the proper hepatic artery with a miriplatin-lipiodol suspension (ML), a fine-powder cisplatin-lipiodol suspension (CL), or saline (control) and the tumor growth rate was determined on MR images acquired before and 7 days after treatment. The concentration of platinum (PCs) in blood was assayed immediately, and 10, 30, and 60 min, and 24 h and 7 days after drug administration. Its concentration in tumor and surrounding normal liver tissues was determined at 7 days postadministration. At high concentrations, fine-powder cisplatin exhibited stronger cytotoxicity than DPC. At low concentrations, both agents manifested weak cytotoxicity. While there was no difference between the tumor growth rate of the ML and the CL groups, the difference between the controls and ML- and CL-treated rabbits was significant. The blood PCs peaked at 10 min and then gradually decreased over time. On the other hand, no platinum was detected at any point after the administration of ML. There was no difference between the ML and CL groups in the PCs in tumor tissues; however, in normal hepatic tissue, the PCs were higher in ML- than CL-treated rabbits. We confirmed the anti-tumor effect of ML and CL. There was no significant difference between the anti-tumor effect of ML and CL at 7 days postadministration.
- 17 May 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 35 (2) , 399-405
Comparison of the Anti-tumor Effects of Two Platinum Agents (Miriplatin and Fine-Powder Cisplatin)
This study was designed to evaluate the anti-tumor effects of miriplatin-lipidol and fine-powder cisplatin–lipiodol suspensions. Assessment of the cytotoxicity of two drugs was performed: a soluble derivative of miriplatin (DPC) and fine-powder cisplatin. We randomly divided 15 rabbits with transplanted VX2 liver tumors into three equal groups. They were infused via the proper hepatic artery with a miriplatin-lipiodol suspension (ML), a fine-powder cisplatin-lipiodol suspension (CL), or saline (control) and the tumor growth rate was determined on MR images acquired before and 7 days after treatment. The concentration of platinum (PCs) in blood was assayed immediately, and 10, 30, and 60 min, and 24 h and 7 days after drug administration. Its concentration in tumor and surrounding normal liver tissues was determined at 7 days postadministration. At high concentrations, fine-powder cisplatin exhibited stronger cytotoxicity than DPC. At low concentrations, both agents manifested weak cytotoxicity. While there was no difference between the tumor growth rate of the ML and the CL groups, the difference between the controls and ML- and CL-treated rabbits was significant. The blood PCs peaked at 10 min and then gradually decreased over time. On the other hand, no platinum was detected at any point after the administration of ML. There was no difference between the ML and CL groups in the PCs in tumor tissues; however, in normal hepatic tissue, the PCs were higher in ML- than CL-treated rabbits. We confirmed the anti-tumor effect of ML and CL. There was no significant difference between the anti-tumor effect of ML and CL at 7 days postadministration.
- 9 April 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (6) , 1272-1277
Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization
- 9 April 2011
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (6) , 1272-1277
Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization
- 15 June 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 33 (4) , 813-817
Cisplatin-Conjugated Porous Gelatin Particles: Assessment of Optimal Conditions for Binding and Release
- 15 June 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 33 (4) , 813-817
Cisplatin-Conjugated Porous Gelatin Particles: Assessment of Optimal Conditions for Binding and Release
- 31 December 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 72 (3) , 534-540
Prolonged local persistence of cisplatin-loaded gelatin microspheres and their chemoembolic anti-cancer effect in rabbits
- 31 December 2009
- Published by Elsevier in European Journal of Radiology
- Vol. 72 (3) , 534-540
Prolonged local persistence of cisplatin-loaded gelatin microspheres and their chemoembolic anti-cancer effect in rabbits