Noritoshi Ushio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Noritoshi Ushio has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Kiyoshi Murata
Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan
7 shared publications - Norihisa Nitta
Department of Radiology, Shiga University of Medical Science, Seta Tsukinowa-cho, Otsu, Shiga, 520-2192, Japan
4 shared publications - Yukihiro Nagatani
Department of Radiology, Shiga University of Medical Science Hospital, Otsu, Japan
4 shared publications - Akinaga Sonoda
Department of Radiology, Shiga University of Medical Science, Seta Tsukinowa-cho, Otsu, Shiga, 520-2192, Japan
3 shared publications - Hideji Otani
Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan
3 shared publications - Masashi Takahashi
Shiga University of Medical Science
3 shared publications
Latest Publications
- 24 September 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (11) , 710-716
Evaluation of the quality of CT images acquired with the single energy metal artifact reduction (SEMAR) algorithm in patients with hip and dental prostheses and aneurysm embolization coils
We compared the quality of the images acquired with single energy metal artifact reduction (SEMAR) on CT scans of three different human body areas.
- 24 September 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (11) , 710-716
Evaluation of the quality of CT images acquired with the single energy metal artifact reduction (SEMAR) algorithm in patients with hip and dental prostheses and aneurysm embolization coils
We compared the quality of the images acquired with single energy metal artifact reduction (SEMAR) on CT scans of three different human body areas.
- 22 September 2012
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 30 (10) , 832-839
Negatively charged superparamagnetic iron oxide nanoparticles: a new blood-pooling magnetic resonance contrast agent
Our purpose was to investigate the utility of superparamagnetic iron-oxide nanoparticles (SPIO) as a blood-pooling contrast agent at magnetic resonance imaging (MRI). We studied four contrast agents: carboxymethyl-diethylaminoethyl dextran magnetite SPIO (CMEADM-S, diameter 54 nm), negatively charged CMEADM ultrasmall SPIO (CMEADM-U, 32 nm), alkali-treated dextran magnetite SPIO (ATDM-S, 55 nm), and ATDM ultrasmall SPIO (ATDM-U, 28 nm) carrying a neutral charge. Each contrast agent (80 μmol/kg) was injected intraperitoneally into apolipoprotein E (apoE) mice and the tissue iron concentration was measured 30-, 60-, 180-, and 300-min later by nuclear MR. For MR angiographic (MRA) evaluation, we injected the agents into the auricular vein of four groups of 15 rabbits. Immediately and 30-, 60-, 180-, and 300-min later, three rabbits from each group were subjected to MRI. The organ/background signal ratio (SR) was calculated. Statistical analyses were performed with Tukey’s honestly significant difference (HSD) test. At 60 and 180 min, blood-iron concentration of CMEADM-U was significantly different from other contrast agents. In the abdominal aorta and inferior vena cava, SR of CMEADM-U was higher at 180 and 300 min than of the other contrast agents. In the thoracic aorta, there was no difference in SR at 300 min between CMEADM-U and CMEADM-S. Negatively charged SPIO nanoparticles may be useful as a blood-pooling contrast agent.
- 22 September 2012
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 30 (10) , 832-839
Negatively charged superparamagnetic iron oxide nanoparticles: a new blood-pooling magnetic resonance contrast agent
Our purpose was to investigate the utility of superparamagnetic iron-oxide nanoparticles (SPIO) as a blood-pooling contrast agent at magnetic resonance imaging (MRI). We studied four contrast agents: carboxymethyl-diethylaminoethyl dextran magnetite SPIO (CMEADM-S, diameter 54 nm), negatively charged CMEADM ultrasmall SPIO (CMEADM-U, 32 nm), alkali-treated dextran magnetite SPIO (ATDM-S, 55 nm), and ATDM ultrasmall SPIO (ATDM-U, 28 nm) carrying a neutral charge. Each contrast agent (80 μmol/kg) was injected intraperitoneally into apolipoprotein E (apoE) mice and the tissue iron concentration was measured 30-, 60-, 180-, and 300-min later by nuclear MR. For MR angiographic (MRA) evaluation, we injected the agents into the auricular vein of four groups of 15 rabbits. Immediately and 30-, 60-, 180-, and 300-min later, three rabbits from each group were subjected to MRI. The organ/background signal ratio (SR) was calculated. Statistical analyses were performed with Tukey’s honestly significant difference (HSD) test. At 60 and 180 min, blood-iron concentration of CMEADM-U was significantly different from other contrast agents. In the abdominal aorta and inferior vena cava, SR of CMEADM-U was higher at 180 and 300 min than of the other contrast agents. In the thoracic aorta, there was no difference in SR at 300 min between CMEADM-U and CMEADM-S. Negatively charged SPIO nanoparticles may be useful as a blood-pooling contrast agent.
- 12 September 2012
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 22 (2) , 89-96
320-detector-row computed tomography arteriography using CO2gas to detect malignant liver tumors
We present the initial steps for 320-detector-row computed tomography arteriography using CO2 gas (320-MDCT CO2 arteriography) to detect the vascular area of malignant liver tumors. This study was approved by the Ethics Committee of our institution. Written prior informed consent was obtained from all patients. We studied six patients with primary and metastatic liver tumors (n = 26) and allergic reactions to iodinated contrast media or a tendency for renal failure. CO2 was injected at 1 ml/sec (volume 8 ml) into the common hepatic artery and a CT scan was acquired 12 seconds after the start of injection. The detection of the vascular area of the tumor or of intratumor air was evaluated with respect to the relationship between the size and location of the tumors. Cramer's V statistic was performed to explore the relationship (p < 0.05). The vascular area was detected in 17 of the 26 tumors (65.4%). There was a correlation between the detection of the adjacent vascular area on CTA images acquired with the use of CO2 and the tumor site observed on previously-acquired MRI or CT images. 320-MDCT CO2 arteriography with microcatheters may be useful for the detection of the vascular area.
- 12 September 2012
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 22 (2) , 89-96
320-detector-row computed tomography arteriography using CO2gas to detect malignant liver tumors
We present the initial steps for 320-detector-row computed tomography arteriography using CO2 gas (320-MDCT CO2 arteriography) to detect the vascular area of malignant liver tumors. This study was approved by the Ethics Committee of our institution. Written prior informed consent was obtained from all patients. We studied six patients with primary and metastatic liver tumors (n = 26) and allergic reactions to iodinated contrast media or a tendency for renal failure. CO2 was injected at 1 ml/sec (volume 8 ml) into the common hepatic artery and a CT scan was acquired 12 seconds after the start of injection. The detection of the vascular area of the tumor or of intratumor air was evaluated with respect to the relationship between the size and location of the tumors. Cramer's V statistic was performed to explore the relationship (p < 0.05). The vascular area was detected in 17 of the 26 tumors (65.4%). There was a correlation between the detection of the adjacent vascular area on CTA images acquired with the use of CO2 and the tumor site observed on previously-acquired MRI or CT images. 320-MDCT CO2 arteriography with microcatheters may be useful for the detection of the vascular area.
- 1 April 2007
- Vol. 61 (2) , 63-9
Resolution of pulmonary multiplanar reconstruction images from 0.5-mm theoretical isotropic data: a fundamental study using an inflated and fixed lung specimen.
The aim of the present study was to define the resolution of multiplanar reconstruction (MPR) of the lung from "theoretical isotropic data." Using inflated and fixed lung specimens of the pig placed in the chest wall phantom, 0.5-mm isotropic data were obtained with 2 different helical pitches: 1:7 (high-quality mode) or 1:13, (high-speed mode), and 2 different tube currents: 250 mAs (high-tube-current mode) or 100 mAs (low-tube-current mode), with or without overlapping reconstruction. MPRs were created from these axial data. The diameter of the smallest visible pulmonary artery and bronchi of these CT images were measured on the corresponding slices of the specimen. The high-speed and low-tube-current mode significantly degraded the image quality due to increased noise. The smallest visible pulmonary artery and bronchus resolved on MPRs from axial-spiral data with 0.5-mm collimation were approximately 100 micrometer and 1,000 micrometer in diameter, respectively. In conclusion, helical pitch and tube current influence the resolution of MPR of the lung.
- 1 April 2007
- Vol. 61 (2) , 63-9
Resolution of pulmonary multiplanar reconstruction images from 0.5-mm theoretical isotropic data: a fundamental study using an inflated and fixed lung specimen.
The aim of the present study was to define the resolution of multiplanar reconstruction (MPR) of the lung from "theoretical isotropic data." Using inflated and fixed lung specimens of the pig placed in the chest wall phantom, 0.5-mm isotropic data were obtained with 2 different helical pitches: 1:7 (high-quality mode) or 1:13, (high-speed mode), and 2 different tube currents: 250 mAs (high-tube-current mode) or 100 mAs (low-tube-current mode), with or without overlapping reconstruction. MPRs were created from these axial data. The diameter of the smallest visible pulmonary artery and bronchi of these CT images were measured on the corresponding slices of the specimen. The high-speed and low-tube-current mode significantly degraded the image quality due to increased noise. The smallest visible pulmonary artery and bronchus resolved on MPRs from axial-spiral data with 0.5-mm collimation were approximately 100 micrometer and 1,000 micrometer in diameter, respectively. In conclusion, helical pitch and tube current influence the resolution of MPR of the lung.
- 1 January 2007
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 71 (1) , 112-121
Multidetector-Row Computed Tomography Coronary Angiography Optimization of Image Reconstruction Phase According to the Heart Rate
To optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who underwent 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, ECG record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates (65 beats/min), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition.
- 1 January 2007
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 71 (1) , 112-121
Multidetector-Row Computed Tomography Coronary Angiography Optimization of Image Reconstruction Phase According to the Heart Rate
To optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who underwent 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, ECG record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates (65 beats/min), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition.