Shingo Baba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shingo Baba has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Honda
Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Japan
9 shared publications- Masayuki Sasaki
Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
7 shared publications Isao Komiya
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Japan
4 shared publicationsKazuhiko Himuro
Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
3 shared publications- Koichiro Abe
Department of Clinical Radiology, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
3 shared publications Masayuki Sasaki
Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
3 shared publications
Latest Publications
- 1 June 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 124, 27-31
Evaluation of the distribution of activation inside a compact medical cyclotron
- 1 June 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 124, 27-31
Evaluation of the distribution of activation inside a compact medical cyclotron
- Open Access
- 1 January 2017
- Vol. 5 (1) , 30-36
The Efficiency of Respiratory-gated 18F-FDG PET/CT in Lung Adenocarcinoma: Amplitude-gating Versus Phase-gating Methods
The PG method was more effective for measuring FDG accumulation of lung lesions under free-breathing conditions in comparison with the AG method.
- 1 January 2017
- Vol. 5 (1) , 30-36
Open AccessThe Efficiency of Respiratory-gated 18F-FDG PET/CT in Lung Adenocarcinoma: Amplitude-gating Versus Phase-gating Methods
The PG method was more effective for measuring FDG accumulation of lung lesions under free-breathing conditions in comparison with the AG method.
- 5 July 2016
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 30 (8) , 518-524
Impact of patient age on the iodine/FDG “flip-flop” phenomenon in lung metastasis from thyroid cancer
- 5 July 2016
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 30 (8) , 518-524
Impact of patient age on the iodine/FDG “flip-flop” phenomenon in lung metastasis from thyroid cancer
- 1 January 2016
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 72 (10) , 989-998
Decontamination of the Activation Product Based on a Legal Revision of the Cyclotron Vault Room on the Non-self-shield Compact Medical Cyclotron
The non-self-shield compact medical cyclotron and the cyclotron vault room were in operation for 27 years. They have now been decommissioned. We efficiently implemented a technique to identify an activation product in the cyclotron vault room. Firstly, the distribution of radioactive concentrations in the concrete of the cyclotron vault room was estimated by calculation from the record of the cyclotron operation. Secondly, the comparison of calculated results with an actual measurement was performed using a NaI scintillation survey meter and a high-purity germanium detector. The calculated values were overestimated as compared to the values measured using the NaI scintillation survey meter and the high-purity germanium detector. However, it could limit the decontamination area. By simulating the activation range, we were able to minimize the concrete core sampling. Finally, the appropriate range of radioactivated area in the cyclotron vault room was decontaminated based on the results of the calculation. After decontamination, the radioactive concentration was below the detection limit value in all areas inside the cyclotron vault room. By these procedures, the decommissioning process of the cyclotron vault room was more efficiently performed.
- 1 January 2016
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 72 (10) , 989-998
Decontamination of the Activation Product Based on a Legal Revision of the Cyclotron Vault Room on the Non-self-shield Compact Medical Cyclotron
The non-self-shield compact medical cyclotron and the cyclotron vault room were in operation for 27 years. They have now been decommissioned. We efficiently implemented a technique to identify an activation product in the cyclotron vault room. Firstly, the distribution of radioactive concentrations in the concrete of the cyclotron vault room was estimated by calculation from the record of the cyclotron operation. Secondly, the comparison of calculated results with an actual measurement was performed using a NaI scintillation survey meter and a high-purity germanium detector. The calculated values were overestimated as compared to the values measured using the NaI scintillation survey meter and the high-purity germanium detector. However, it could limit the decontamination area. By simulating the activation range, we were able to minimize the concrete core sampling. Finally, the appropriate range of radioactivated area in the cyclotron vault room was decontaminated based on the results of the calculation. After decontamination, the radioactive concentration was below the detection limit value in all areas inside the cyclotron vault room. By these procedures, the decommissioning process of the cyclotron vault room was more efficiently performed.
- 26 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1926-1935
Monte Carlo simulation of PET and SPECT imaging of90Y
Purpose: Yittrium‐90 (90Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single‐photon emission computed tomography (SPECT). However, because 90Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of 90Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo‐based simulation–reconstruction framework for 90Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP‐PET) generates a sinogram, and reconstructs the tomography image using a time‐of‐flight ordered subset expectation maximization (TOF‐OSEM) algorithm with attenuation compensation. To evaluate MCEP‐PET, simulated results of 18F PET imaging were compared with the experimental results. The results confirmed that MCEP‐PET can simulate the experimental results very well. The SPECT code (MCEP‐SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded 90Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of 90Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated 90Y‐PET image accurately simulated the experimental results. PET image is visually superior to SPECT image because of the low background noise. The simulation reveals that the detected photon number in SPECT is comparable to that of PET, but the large fraction (approximately 75%) of scattered and penetration photons contaminates SPECT image. The lower limit of 90Y detection in SPECT image was approximately 200 kBq/ml, while that in PET image was approximately 100 kBq/ml. Conclusions: By comparing the background noise level and the image concentration profile of both the techniques, PET image quality was determined to be superior to that of bremsstrahlung SPECT. The developed simulation codes will be very useful in the future investigations of PET and bremsstrahlung SPECT imaging of 90Y.
- 26 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1926-1935
Monte Carlo simulation of PET and SPECT imaging of90Y
Purpose: Yittrium‐90 (90Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single‐photon emission computed tomography (SPECT). However, because 90Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of 90Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo‐based simulation–reconstruction framework for 90Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP‐PET) generates a sinogram, and reconstructs the tomography image using a time‐of‐flight ordered subset expectation maximization (TOF‐OSEM) algorithm with attenuation compensation. To evaluate MCEP‐PET, simulated results of 18F PET imaging were compared with the experimental results. The results confirmed that MCEP‐PET can simulate the experimental results very well. The SPECT code (MCEP‐SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded 90Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of 90Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated 90Y‐PET image accurately simulated the experimental results. PET image is visually superior to SPECT image because of the low background noise. The simulation reveals that the detected photon number in SPECT is comparable to that of PET, but the large fraction (approximately 75%) of scattered and penetration photons contaminates SPECT image. The lower limit of 90Y detection in SPECT image was approximately 200 kBq/ml, while that in PET image was approximately 100 kBq/ml. Conclusions: By comparing the background noise level and the image concentration profile of both the techniques, PET image quality was determined to be superior to that of bremsstrahlung SPECT. The developed simulation codes will be very useful in the future investigations of PET and bremsstrahlung SPECT imaging of 90Y.
- 23 December 2014
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 43 (1) , 41-46
An Anthropomorphic Phantom Study of Brain Dopamine Transporter SPECT Images Obtained Using Different SPECT/CT Devices and Collimators
The aim of this study was to evaluate differences in dopamine transporter SPECT images among different SPECT/CT devices and to determine the most appropriate region of interest (ROI) for semiquantitative evaluation. Methods: An anthropomorphic striatal phantom was filled with 123I solutions of different striatum-to-background radioactivity ratios. Data were acquired using 2 SPECT/CT devices equipped with low- to medium-energy general-purpose and low-energy high-resolution (LEHR) collimators. The SPECT images were reconstructed by filtered backprojection with both attenuation and scatter correction and then were analyzed using specific binding ratio (SBR). The most appropriate of 7 ROI types was determined, and we then compared the linearity and recovery of SBR among the different SPECT/CT devices and collimators. Results: The linearity of SBR was excellent for all types of ROIs. The ROI contouring the striatum based on the CT images showed the best recovery of SBR using mean activity in the striatal ROI (SBRmean) (47.8%). For this ROI, the recovery of SBRmean for SPECT/CT with a LEHR collimator with thick septa and a long hole length was 61.6%—significantly higher than that of other devices. Conclusion: The ROI contouring the striatum based on CT images was considered appropriate for evaluating dopamine transporter SPECT/CT. Among the different SPECT/CT devices, an LEHR collimator designed for 123II imaging is recommended.
- 23 December 2014
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 43 (1) , 41-46
An Anthropomorphic Phantom Study of Brain Dopamine Transporter SPECT Images Obtained Using Different SPECT/CT Devices and Collimators
The aim of this study was to evaluate differences in dopamine transporter SPECT images among different SPECT/CT devices and to determine the most appropriate region of interest (ROI) for semiquantitative evaluation. Methods: An anthropomorphic striatal phantom was filled with 123I solutions of different striatum-to-background radioactivity ratios. Data were acquired using 2 SPECT/CT devices equipped with low- to medium-energy general-purpose and low-energy high-resolution (LEHR) collimators. The SPECT images were reconstructed by filtered backprojection with both attenuation and scatter correction and then were analyzed using specific binding ratio (SBR). The most appropriate of 7 ROI types was determined, and we then compared the linearity and recovery of SBR among the different SPECT/CT devices and collimators. Results: The linearity of SBR was excellent for all types of ROIs. The ROI contouring the striatum based on the CT images showed the best recovery of SBR using mean activity in the striatal ROI (SBRmean) (47.8%). For this ROI, the recovery of SBRmean for SPECT/CT with a LEHR collimator with thick septa and a long hole length was 61.6%—significantly higher than that of other devices. Conclusion: The ROI contouring the striatum based on CT images was considered appropriate for evaluating dopamine transporter SPECT/CT. Among the different SPECT/CT devices, an LEHR collimator designed for 123II imaging is recommended.
- 1 December 2014
- Vol. 72 (12) , 2181-5
[Targeted radionuclide therapy for castration-resistant prostate cancer].
Although patients with castration-resistant prostate cancer frequently have metastases to the bone, they have a relatively favorable prognosis. Therefore, it is important to keep or improve the level of patient's quality of life. The use of strontium-89 for the management of the pain from bone metastasis was approved in 2007 in Japan. A new bone-targeting radiopharmaceuticals using radium-223 is also promising, because a randomized trial showed an overall survival advantage of radium-223 in prostate patients with bone metastases. In this review, we summarize the role of targeted radionuclide therapy for castration-resistant prostate cancer, focusing on strontium-89 and radium-223.
- 1 December 2014
- Vol. 72 (12) , 2181-5
[Targeted radionuclide therapy for castration-resistant prostate cancer].
Although patients with castration-resistant prostate cancer frequently have metastases to the bone, they have a relatively favorable prognosis. Therefore, it is important to keep or improve the level of patient's quality of life. The use of strontium-89 for the management of the pain from bone metastasis was approved in 2007 in Japan. A new bone-targeting radiopharmaceuticals using radium-223 is also promising, because a randomized trial showed an overall survival advantage of radium-223 in prostate patients with bone metastases. In this review, we summarize the role of targeted radionuclide therapy for castration-resistant prostate cancer, focusing on strontium-89 and radium-223.
- 1 June 2014
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 39 (6) , e340-e342
PET/CT Findings in Acute Gastric Anisakiasis
Acute gastric anisakiasis is caused by the consumption of raw or undercooked fish containing Anisakis larvae. Although several reports have demonstrated the CT features of acute gastric anisakiasis, little is known about the FDG PET/CT findings. We report a 59-year-old woman who underwent FDG PET/CT and was finally diagnosed as having acute gastric anisakiasis. The PET/CT demonstrated focal FDG accumulation in the fornix of the gastric wall and lymph nodes in the lesser curvature and paraaortic regions.
- 1 June 2014
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 39 (6) , e340-e342
PET/CT Findings in Acute Gastric Anisakiasis
Acute gastric anisakiasis is caused by the consumption of raw or undercooked fish containing Anisakis larvae. Although several reports have demonstrated the CT features of acute gastric anisakiasis, little is known about the FDG PET/CT findings. We report a 59-year-old woman who underwent FDG PET/CT and was finally diagnosed as having acute gastric anisakiasis. The PET/CT demonstrated focal FDG accumulation in the fornix of the gastric wall and lymph nodes in the lesser curvature and paraaortic regions.
- Open Access
- 24 March 2014
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 55 (5) , 736-742
Diagnostic and Prognostic Value of Pretreatment SUV in 18F-FDG/PET in Breast Cancer: Comparison with Apparent Diffusion Coefficient from Diffusion-Weighted MR Imaging
In oncology, the apparent diffusion coefficient (ADC) measured by diffusion-weighted MR imaging (DWI) and the standardized uptake value (SUV) from 18F-FDG PET have similar clinical applications. The purpose of this study was to assess the correlation between the ADC and SUV and compare their potential in the diagnosis and prediction of prognosis in breast tumors. Methods: Seventy-nine female patients (age range, 19–69 y; average, 49.1 y) with 83 pathologically proven breast tumors were recruited. The diagnoses consisted of 70 malignant breast tumors (65 cases of invasive ductal carcinoma, 1 of medullary carcinoma, 1 of mucinous carcinoma, 1 of squamous cell carcinoma, and 2 of micropapillary carcinoma) and 13 benign breast tumors (4 cases of fibroadenoma, 4 of mastopathy, 3 of adenosis with atypia, and 2 of benign phyllodes tumor). All patients underwent mammary gland MR imaging with DWI and 18F-FDG PET within a 2-wk interval. The patients’ ADCs and SUVs were measured within the tumor by DWI and 18F-FDG PET, respectively. For the malignant tumors, we evaluated the relationships among ADC, SUV, histopathologic appearance, and long-term prognosis. Results: A significant difference (P < 0.05) was observed in both parameters (ADC and SUV) between the benign and malignant breast tumors, and the difference was more significant when we introduced a new parameter, SUV/ADC. There was a weak inverse correlation between ADC and SUV (r = −0.36; P = 0.06) among the total tumors; however, this correlation was not significant within the group of malignant tumors. High SUV was found to correlate with larger tumor size, higher nuclear grade, and the triple-negative hormonal receptor profile. High ADC was revealed to be correlated with negative progesterone receptor and positive human epidermal growth factor receptor 2 profile. Higher SUVs also showed a correlation with poor prognosis. No correlation was seen between ADC and prognosis. Conclusion: Both SUV and ADC are helpful parameters in differentiating benign from malignant breast tumors. The use of SUV and ADC in combination may help in the diagnosis because of their inverse relationship. High preoperative SUV was associated with poor prognosis, but the contribution of ADC to prognosis prediction was small.
- 24 March 2014
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 55 (5) , 736-742
Open AccessDiagnostic and Prognostic Value of Pretreatment SUV in 18F-FDG/PET in Breast Cancer: Comparison with Apparent Diffusion Coefficient from Diffusion-Weighted MR Imaging
In oncology, the apparent diffusion coefficient (ADC) measured by diffusion-weighted MR imaging (DWI) and the standardized uptake value (SUV) from 18F-FDG PET have similar clinical applications. The purpose of this study was to assess the correlation between the ADC and SUV and compare their potential in the diagnosis and prediction of prognosis in breast tumors. Methods: Seventy-nine female patients (age range, 19–69 y; average, 49.1 y) with 83 pathologically proven breast tumors were recruited. The diagnoses consisted of 70 malignant breast tumors (65 cases of invasive ductal carcinoma, 1 of medullary carcinoma, 1 of mucinous carcinoma, 1 of squamous cell carcinoma, and 2 of micropapillary carcinoma) and 13 benign breast tumors (4 cases of fibroadenoma, 4 of mastopathy, 3 of adenosis with atypia, and 2 of benign phyllodes tumor). All patients underwent mammary gland MR imaging with DWI and 18F-FDG PET within a 2-wk interval. The patients’ ADCs and SUVs were measured within the tumor by DWI and 18F-FDG PET, respectively. For the malignant tumors, we evaluated the relationships among ADC, SUV, histopathologic appearance, and long-term prognosis. Results: A significant difference (P < 0.05) was observed in both parameters (ADC and SUV) between the benign and malignant breast tumors, and the difference was more significant when we introduced a new parameter, SUV/ADC. There was a weak inverse correlation between ADC and SUV (r = −0.36; P = 0.06) among the total tumors; however, this correlation was not significant within the group of malignant tumors. High SUV was found to correlate with larger tumor size, higher nuclear grade, and the triple-negative hormonal receptor profile. High ADC was revealed to be correlated with negative progesterone receptor and positive human epidermal growth factor receptor 2 profile. Higher SUVs also showed a correlation with poor prognosis. No correlation was seen between ADC and prognosis. Conclusion: Both SUV and ADC are helpful parameters in differentiating benign from malignant breast tumors. The use of SUV and ADC in combination may help in the diagnosis because of their inverse relationship. High preoperative SUV was associated with poor prognosis, but the contribution of ADC to prognosis prediction was small.
- 1 January 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (1) , 226-230
Influences of point-spread function and time-of-flight reconstructions on standardized uptake value of lymph node metastases in FDG-PET
- 1 January 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (1) , 226-230
Influences of point-spread function and time-of-flight reconstructions on standardized uptake value of lymph node metastases in FDG-PET