Alessandro Blandino
Research Subjects
Alessandro Blandino has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Francesca Bianchi
Division of Cardiology, Mauriziano Umberto I Hospital, Turin, Italy
4 shared publicationsStefano Grossi
Division of Cardiology, Mauriziano Umberto I Hospital, Turin, Italy
4 shared publicationsMarco Scaglione
Division of Cardiology, Department of Internal Medicine, Cardinal Gugliemo Massaia Hospital, Asti, Italy
3 shared publicationsAndrea Sibona Masi
Division of Cardiology, Mauriziano Umberto I Hospital, Turin, Italy
2 shared publicationsElisabetta Toso
Cardiology Division Department of Internal Medicine San Giovanni Battista Hospital University of Turin Italy
2 shared publicationsFiorenzo Gaita
Division of Cardiology, Department of Medical Sciences, Città della salute e della scienza, University of Turin, Turin, Italy
2 shared publications
Latest Publications
- 26 August 2021
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 66 (1) , 179-192
Safety and efficacy of catheter ablation for ventricular tachycardia in elderly patients with structural heart disease: a systematic review and meta-analysis
Purpose Data regarding the age-specific outcomes of VT ablation in patients with structural heart disease (SHD) are scarce. We performed a systematic review and meta-analysis to evaluate the outcomes of VT ablation in elderly vs. younger patients with SHD. Methods MEDLINE/PubMed, Cochrane, and Google Scholar and references comparing VT ablation in elderly vs. younger patients were screened and studies included if matching inclusion and exclusion criteria. Results Five retrospective studies enrolling 2778 SHD patients (868 elderly vs. 1910 younger) were included. Compared to younger subjects, the elderly showed similar results in terms of acute ablation success (OR 0.78, 95% CI 0.54–1.13, p = 0.189) and minor complications (OR 1.74, 95% CI 0.74–4.09, p = 0.205), a trend toward a higher risk of major complications (OR 2.30, 95% CI 0.83–6.40, p = 0.110) and significantly higher rates of all complications (OR 2.67, 95% CI 1.51–4.71, p = 0.001) and periprocedural mortality (OR 1.93, 95% CI 1.24–3.01, p = 0.004). At a mean follow-up of 18 months, elderly patients showed similar long-term VT recurrence rate (OR 1.02, 95% CI 0.85–1.22, p = 0.861) and higher all-cause mortality (OR 2.00, 95% CI 1.40–2.86, p < 0.001). In elderly patients, urgent VT ablation is associated with higher risk of major complications (beta = 0.06, p < 0.001) and periprocedural mortality (beta = 0.03, p = 0.029), while advanced age is associated with higher risk of major complications (beta = 0.29 with p = 0.009) and all complications + periprocedural mortality (beta = 0.17 with p = 0.037). Conclusions Compared to younger patients, VT ablation in elderly showed similar results in terms of acute ablation success and long-term VT recurrence rate with a significantly higher risk of all complications, periprocedural mortality, and long-term mortality, especially when the procedure is performed urgently and in the most aged patients. Large prospective multicenter randomized trials are required to confirm these findings.
- 26 August 2021
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 66 (1) , 179-192
Safety and efficacy of catheter ablation for ventricular tachycardia in elderly patients with structural heart disease: a systematic review and meta-analysis
Purpose Data regarding the age-specific outcomes of VT ablation in patients with structural heart disease (SHD) are scarce. We performed a systematic review and meta-analysis to evaluate the outcomes of VT ablation in elderly vs. younger patients with SHD. Methods MEDLINE/PubMed, Cochrane, and Google Scholar and references comparing VT ablation in elderly vs. younger patients were screened and studies included if matching inclusion and exclusion criteria. Results Five retrospective studies enrolling 2778 SHD patients (868 elderly vs. 1910 younger) were included. Compared to younger subjects, the elderly showed similar results in terms of acute ablation success (OR 0.78, 95% CI 0.54–1.13, p = 0.189) and minor complications (OR 1.74, 95% CI 0.74–4.09, p = 0.205), a trend toward a higher risk of major complications (OR 2.30, 95% CI 0.83–6.40, p = 0.110) and significantly higher rates of all complications (OR 2.67, 95% CI 1.51–4.71, p = 0.001) and periprocedural mortality (OR 1.93, 95% CI 1.24–3.01, p = 0.004). At a mean follow-up of 18 months, elderly patients showed similar long-term VT recurrence rate (OR 1.02, 95% CI 0.85–1.22, p = 0.861) and higher all-cause mortality (OR 2.00, 95% CI 1.40–2.86, p < 0.001). In elderly patients, urgent VT ablation is associated with higher risk of major complications (beta = 0.06, p < 0.001) and periprocedural mortality (beta = 0.03, p = 0.029), while advanced age is associated with higher risk of major complications (beta = 0.29 with p = 0.009) and all complications + periprocedural mortality (beta = 0.17 with p = 0.037). Conclusions Compared to younger patients, VT ablation in elderly showed similar results in terms of acute ablation success and long-term VT recurrence rate with a significantly higher risk of all complications, periprocedural mortality, and long-term mortality, especially when the procedure is performed urgently and in the most aged patients. Large prospective multicenter randomized trials are required to confirm these findings.
- 6 April 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (6) , 1102-1114
Outcomes of manual versus remote magnetic navigation for catheter ablation of ventricular tachycardia: a systematic review and updated meta‐analysis
Purpose: Ventricular tachycardia (VT) ablation is a complex procedure that requires remarkable catheter manipulation skill, great mapping accuracy and catheter stability, and can expose patients to serious complications. Magnetic navigation system (RMN)‐guided ablation and contact force‐sensing (CFS) catheters have the potential to overcome these obstacles. We performed a systematic review and updated meta‐analysis of all available studies evaluating the outcomes of VT ablation by using RMN‐guided compared to manual navigation (MAN)‐guided, with and without CFS catheters.Methods: MEDLINE/PubMed, Cochrane, and Google Scholar were searched for randomized controlled trials (RCT) or observational studies with multivariate adjustment comparing RMN‐guided versus MAN‐guided VT ablation.Results: Thirteen studies enrolling 1348 patients (656 RMN‐guided vs. 692 MAN‐guided) were included. CFS catheter were used in 14% of MAN‐guided patients. In comparison to MAN‐guided and CFS‐guided, RMN‐guided VT ablation was associated with a significant higher acute ablation success (OR 2.32, 1.66–3.23 and OR 2.91, 1.29–6.53, respectively) but similar results in term of long‐term VT recurrence (OR 0.75, 0.56–1.01 and OR 0.79, 0.27–2.36, respectively). RMN‐guided showed a better safety profile (for all complications, OR 0.52, 0.34–0.81) and allowed a significant x‐ray reduction compared to MAN‐guided (OR 0.21, 0.14–0.32) and CFS‐guided VT ablation (OR 0.23, 0.11–0.52, all 95% CI).Conclusions: RMN‐guided was superior to MAN‐guided and CFS‐guided VT ablation in term of acute ablation success, all complications endpoint, and reduction of fluoroscopy exposure, but did not reduce long‐term VT recurrence. Large prospective multicenter randomized trials are needed to confirm these findings.
- 6 April 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (6) , 1102-1114
Outcomes of manual versus remote magnetic navigation for catheter ablation of ventricular tachycardia: a systematic review and updated meta‐analysis
Purpose: Ventricular tachycardia (VT) ablation is a complex procedure that requires remarkable catheter manipulation skill, great mapping accuracy and catheter stability, and can expose patients to serious complications. Magnetic navigation system (RMN)‐guided ablation and contact force‐sensing (CFS) catheters have the potential to overcome these obstacles. We performed a systematic review and updated meta‐analysis of all available studies evaluating the outcomes of VT ablation by using RMN‐guided compared to manual navigation (MAN)‐guided, with and without CFS catheters.Methods: MEDLINE/PubMed, Cochrane, and Google Scholar were searched for randomized controlled trials (RCT) or observational studies with multivariate adjustment comparing RMN‐guided versus MAN‐guided VT ablation.Results: Thirteen studies enrolling 1348 patients (656 RMN‐guided vs. 692 MAN‐guided) were included. CFS catheter were used in 14% of MAN‐guided patients. In comparison to MAN‐guided and CFS‐guided, RMN‐guided VT ablation was associated with a significant higher acute ablation success (OR 2.32, 1.66–3.23 and OR 2.91, 1.29–6.53, respectively) but similar results in term of long‐term VT recurrence (OR 0.75, 0.56–1.01 and OR 0.79, 0.27–2.36, respectively). RMN‐guided showed a better safety profile (for all complications, OR 0.52, 0.34–0.81) and allowed a significant x‐ray reduction compared to MAN‐guided (OR 0.21, 0.14–0.32) and CFS‐guided VT ablation (OR 0.23, 0.11–0.52, all 95% CI).Conclusions: RMN‐guided was superior to MAN‐guided and CFS‐guided VT ablation in term of acute ablation success, all complications endpoint, and reduction of fluoroscopy exposure, but did not reduce long‐term VT recurrence. Large prospective multicenter randomized trials are needed to confirm these findings.
- 5 January 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 40 (2) , 199-212
Left Atrial Substrate Modification Targeting Low‐Voltage Areas for Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta‐Analysis
Background: This meta‐analysis aims to assess the impact of a voltage‐guided substrate modification by targeting low‐voltage area (LVA) in addition to pulmonary vein isolation (PVI) in patients undergoing catheter ablation for atrial fibrillation (AF).Methods: MEDLINE/PubMed, Cochrane Library, and references reporting AF ablation and “voltage* OR substrate* OR fibrosis OR fibrotic area*” were screened and studies included if matching inclusion and exclusion criteria.Results: Six studies were included. Patients enrolled were 885 (517 in the study group and 368 in the control group). Median age was 60 years; 92% had nonparoxysmal AF. At a mean follow‐up of 17 months, 70% of patients in the study group vs. 43% in the control group were free from AF/atrial tachycardia (AT) recurrences (odds ratio [OR] = 3.41, 95% confidence interval [CI] 2.22–5.24). LVA ablation in addition to PVI was more effective than PVI alone and PVI + conventional wide empirical ablation (70% vs. 43%, OR = 3.41, 95% CI 2.22–5.24), without increasing the adverse event rate (2.5% vs. 6%, OR = 0.43, 95% CI 0.15–1.26). Compared to PVI + conventional wide empirical ablation, LVA ablation reduced the occurrence of postablation AT (14% vs. 46%, OR = 0.16, 95% CI 0.07–0.37), procedure time (176 min vs. 220 min, OR = 0.36, 95% CI 0.24–0.56), fluoroscopy time (25 min vs. 31 min, OR = 0.22, 95% CI 0.12–0.39), and radiofrequency time (55 min vs. 90 min, OR = 0.49, 95% CI 0.27–0.90).Conclusions: A voltage‐guided substrate modification by targeting LVA in addition to PVI is more effective, safer, and holds a lower proarrhythmic potential than conventional ablation approaches. Further randomized studies are necessary to confirm these findings.
- 5 January 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 40 (2) , 199-212
Left Atrial Substrate Modification Targeting Low‐Voltage Areas for Catheter Ablation of Atrial Fibrillation: A Systematic Review and Meta‐Analysis
Background: This meta‐analysis aims to assess the impact of a voltage‐guided substrate modification by targeting low‐voltage area (LVA) in addition to pulmonary vein isolation (PVI) in patients undergoing catheter ablation for atrial fibrillation (AF).Methods: MEDLINE/PubMed, Cochrane Library, and references reporting AF ablation and “voltage* OR substrate* OR fibrosis OR fibrotic area*” were screened and studies included if matching inclusion and exclusion criteria.Results: Six studies were included. Patients enrolled were 885 (517 in the study group and 368 in the control group). Median age was 60 years; 92% had nonparoxysmal AF. At a mean follow‐up of 17 months, 70% of patients in the study group vs. 43% in the control group were free from AF/atrial tachycardia (AT) recurrences (odds ratio [OR] = 3.41, 95% confidence interval [CI] 2.22–5.24). LVA ablation in addition to PVI was more effective than PVI alone and PVI + conventional wide empirical ablation (70% vs. 43%, OR = 3.41, 95% CI 2.22–5.24), without increasing the adverse event rate (2.5% vs. 6%, OR = 0.43, 95% CI 0.15–1.26). Compared to PVI + conventional wide empirical ablation, LVA ablation reduced the occurrence of postablation AT (14% vs. 46%, OR = 0.16, 95% CI 0.07–0.37), procedure time (176 min vs. 220 min, OR = 0.36, 95% CI 0.24–0.56), fluoroscopy time (25 min vs. 31 min, OR = 0.22, 95% CI 0.12–0.39), and radiofrequency time (55 min vs. 90 min, OR = 0.49, 95% CI 0.27–0.90).Conclusions: A voltage‐guided substrate modification by targeting LVA in addition to PVI is more effective, safer, and holds a lower proarrhythmic potential than conventional ablation approaches. Further randomized studies are necessary to confirm these findings.
- 23 May 2016
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 46 (3) , 225-236
Apixaban for periprocedural anticoagulation during catheter ablation of atrial fibrillation: a systematic review and meta-analysis of 1691 patients
Apixaban, a direct factor Xa inhibitor recently approved for thromboembolic prophylaxis in patients with nonvalvular atrial fibrillation (AF), is increasingly used in patients undergoing catheter ablation of AF. However, large randomized studies supporting its use in the ablation context are still lacking. We undertook the present meta-analysis to assess the impact of apixaban in terms of thromboembolic and bleeding events in patients undergoing AF ablation as compared to warfarin.
- 23 May 2016
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 46 (3) , 225-236
Apixaban for periprocedural anticoagulation during catheter ablation of atrial fibrillation: a systematic review and meta-analysis of 1691 patients
Apixaban, a direct factor Xa inhibitor recently approved for thromboembolic prophylaxis in patients with nonvalvular atrial fibrillation (AF), is increasingly used in patients undergoing catheter ablation of AF. However, large randomized studies supporting its use in the ablation context are still lacking. We undertook the present meta-analysis to assess the impact of apixaban in terms of thromboembolic and bleeding events in patients undergoing AF ablation as compared to warfarin.
- 1 April 2013
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 24 (7) , 731-738
Long‐Term Efficacy and Safety of Two Different Rhythm Control Strategies in Elderly Patients with Symptomatic Persistent Atrial Fibrillation
Ablation versus Drugs in Elderly Persistent AF: Background: We prospectively compared the efficacy, safety, and quality of life (QoL) impact of catheter ablation versus antiarrhythmic drugs (AAD) in elderly patients with persistent atrial fibrillation (AF).Methods and Results: Four hundred and twelve consecutive patients, aged ≥ 70 years, underwent ablation (Group A, 153 patients) or AAD (Group B, 259 patients). Study endpoints: treatment failure (any AF/AT lasting >30 seconds) and treatment‐related adverse events (acute when ≤1 month of procedure and long term when >1 month). At a follow‐up of 60 ± 17 months, 43% and 46% patients in Group B versus 58% and 76% in Group A were in sinus rhythm (SR), respectively, after one (P = 0.003) and 2 procedures (P < 0.001). Fifteen acute adverse events occurred (6.7% in Group A vs 1% in Group B, P < 0.001), mainly periprocedural cerebral thromboembolism (3.3% in Group A vs 0.7% in Group B, P = 0.058). Previous TIA/stroke resulted the only independent predictor of periprocedural cerebrovascular accidents (OR 1.2, 95%IC 1.1–1.3). At follow‐up, 74 long‐term adverse events occurred (7.7% in Group A vs 23.9% in Group B, P < 0.001) with Group B patients more often experiencing AAD‐related adverse events (12.7% vs 2.6%, P < 0.001). Group A and absence of AF/AT recurrences significantly improved QoL scores (P < 0.001).Conclusions: In elderly persistent AF patients, catheter ablation is more effective in maintaining SR and in improving QoL than AAD but is affected by a higher risk of embolic complications, particularly in patients with previous TIA/stroke. Over time, Group A patients more likely discontinued AAD with a reduction of long‐term adverse events.
- 1 April 2013
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 24 (7) , 731-738
Long‐Term Efficacy and Safety of Two Different Rhythm Control Strategies in Elderly Patients with Symptomatic Persistent Atrial Fibrillation
Ablation versus Drugs in Elderly Persistent AF: Background: We prospectively compared the efficacy, safety, and quality of life (QoL) impact of catheter ablation versus antiarrhythmic drugs (AAD) in elderly patients with persistent atrial fibrillation (AF).Methods and Results: Four hundred and twelve consecutive patients, aged ≥ 70 years, underwent ablation (Group A, 153 patients) or AAD (Group B, 259 patients). Study endpoints: treatment failure (any AF/AT lasting >30 seconds) and treatment‐related adverse events (acute when ≤1 month of procedure and long term when >1 month). At a follow‐up of 60 ± 17 months, 43% and 46% patients in Group B versus 58% and 76% in Group A were in sinus rhythm (SR), respectively, after one (P = 0.003) and 2 procedures (P < 0.001). Fifteen acute adverse events occurred (6.7% in Group A vs 1% in Group B, P < 0.001), mainly periprocedural cerebral thromboembolism (3.3% in Group A vs 0.7% in Group B, P = 0.058). Previous TIA/stroke resulted the only independent predictor of periprocedural cerebrovascular accidents (OR 1.2, 95%IC 1.1–1.3). At follow‐up, 74 long‐term adverse events occurred (7.7% in Group A vs 23.9% in Group B, P < 0.001) with Group B patients more often experiencing AAD‐related adverse events (12.7% vs 2.6%, P < 0.001). Group A and absence of AF/AT recurrences significantly improved QoL scores (P < 0.001).Conclusions: In elderly persistent AF patients, catheter ablation is more effective in maintaining SR and in improving QoL than AAD but is affected by a higher risk of embolic complications, particularly in patients with previous TIA/stroke. Over time, Group A patients more likely discontinued AAD with a reduction of long‐term adverse events.
- 1 October 2012
- Published by Il Pensiero Scientifico Editore in Giornale Italiano di Cardiologia
- Vol. 13 (10) , 21-28
L’ablazione con radiofrequenza della fibrillazione atriale: com’è cambiata dal 1996 ad oggi
Dalla seconda metà degli anni ’90, l’ablazione della fibrillazione atriale (FA) si è profondamente trasformata, da una tecnica essenzialmente investigativa ed eseguita in rari e selezionati pazienti, a una metodica terapeutica di comune utilizzo, eseguita in centinaia di laboratori nel mondo e offerta a pazienti con caratteristiche cliniche e tipi di FA eterogenei. Scopo di questa revisione è valutare quali sono state le principali tappe nell’evoluzione dell’ablazione di FA, offrendo inoltre una sintesi di quelli che sono gli attuali risultati e le attuali indicazioni cliniche.
- 1 October 2012
- Published by Il Pensiero Scientifico Editore in Giornale Italiano di Cardiologia
- Vol. 13 (10) , 21-28
L’ablazione con radiofrequenza della fibrillazione atriale: com’è cambiata dal 1996 ad oggi
Dalla seconda metà degli anni ’90, l’ablazione della fibrillazione atriale (FA) si è profondamente trasformata, da una tecnica essenzialmente investigativa ed eseguita in rari e selezionati pazienti, a una metodica terapeutica di comune utilizzo, eseguita in centinaia di laboratori nel mondo e offerta a pazienti con caratteristiche cliniche e tipi di FA eterogenei. Scopo di questa revisione è valutare quali sono state le principali tappe nell’evoluzione dell’ablazione di FA, offrendo inoltre una sintesi di quelli che sono gli attuali risultati e le attuali indicazioni cliniche.