MSMichael Sandborg

Michael Sandborg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Sandborg has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages

    by Michael Sandborg, Anders Tingberg, Gustaf Ullman, David R. Dance, Gudrun Alm Carlsson

    The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists’ observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range , including those values typically used with screen‐film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x‐ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal‐to‐noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen‐film radiography are discussed, as well as the relevance of using VGAS and quantum‐noise SNR as measures of image quality in pelvis and chest radiography.


  • Open Access

    Effect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function

    by Alexandr Malušek, Maria Magnusson Seger, Michael Sandborg, Gudrun Alm Carlsson

    The effect of scatter on reconstructed image quality in cone beam computed tomography was investigated and a function which can be used in scatter-reduction optimisation tasks was tested. Projections were calculated using the Monte Carlo method in an axially symmetric cone beam geometry consisting of a point source, water phantom and a single row of detector elements. Image reconstruction was performed using the filtered backprojection method. Image quality was assessed by the L2-norm-based difference relative to a reference image derived from (1) weighted linear attenuation coefficients and (2) projections by primary photons. It was found that the former function was strongly affected by the beam hardening artefact and did not properly reflect the amount of scatter but the latter function increased with increasing beam width, was higher for the larger phantom and exhibited properties which made it a good candidate for scatter-reduction optimisation tasks using polyenergetic beams.


  • The influence of patient thickness and imaging system on patient dose and physical image quality in digital chest imaging

    by Gustaf Ullman, Michael Sandborg, David R. Dance, Roger Hunt, Gudrun Alm Carlsson

    The aim of this work was to study the influence of patient thickness, tube voltage and image detector on patient dose, contrast and ideal observer signal-to-noise ratio (SNRI), for pathological details positioned at different regions in the image in posterior–anterior (PA) chest radiology. A Monte Carlo computational model was used to compute measures of physical image quality (contrast, SNRI) and patient effective dose, E. Two metastasis-like details positioned in the central right lung and right lung near the spine, respectively, were studied. The tube voltage was varied between 100 and 150 kV and the patient thickness between 20 and 28 cm. Both, a computed radiography (CR) system and a direct radiography (DR) system, were investigated. The DR system provides both lower doses and better image quality compared with the CR system. The \(\mathrm{SNR}_{\mathrm{I}}^{2}/E\) is ∼2.9 times higher for the DR system compared with the CR system.


  • Inter-observer variation in masked and unmasked images for quality evaluation of clinical radiographs

    by Anders Tingberg, Fredrik Eriksson, Joakim Medin, Jack Besjakov, Magnus Båth, Markus Håkansson, Michael Sandborg, Anja Almén, Birgitta Lanhede, Gudrun Alm-Carlsson, et al.

    Purpose: To investigate the influence of masking on the inter-observer variation in image quality evaluation of clinical radiographs of chest and lumbar spine. Background: Inter-observer variation is a big problem in image quality evaluation since this variation is often much bigger than the variation in image quality between, for example, two radiographic systems. In this study, we have evaluated the effect of masking on the inter-observer variation. The idea of the masking was to force every observer to view exactly the same part of the image and to avoid the effect of the overall ‘first impression’ of the image. A discussion with a group of European expert radiologists before the study indicated that masking might be a good way to reduce the inter-observer variation. Methods: Five chest and five lumbar spine radiographs were collected together with detailed information regarding exposure conditions. The radiographs were digitised with a high-performance scanner and five different manipulations were performed, simulating five different exposure conditions. The contrast, noise and spatial resolution were manipulated by this method. The images were printed onto the film and the individual masks were produced for each film, showing only the parts of the images that were necessary for the image quality evaluation. The quality of the images was evaluated on ordinary viewing boxes by a large group of experienced radiologists. The images were examined with and without the masks with a set of image criteria (if fulfilled, 1 point; and not fulfilled, 0 point), and the mean score was calculated for each simulated exposure condition. Results: The results of this study indicate that—contrary to what was supposed—the inter-observer variation increased when the images were masked. In some cases, especially for chest, this increase was statistically significant. Conclusions: Based on the results of this study, image masking in studies of fulfilment of image criteria cannot be recommended.


  • Evaluation of patient-absorbed doses during coronary angiography and intervention by femoral and radial artery access

    by Michael Sandborg, Sven-Göran Fransson, Håkan Pettersson

    The aim of this study was to compare the radiation dose to patients during coronary angiography (CA) and coronary intervention (percutaneous transluminal coronary angioplasty, PTCA) by the femoral or radial artery access routes. A plane-parallel ionisation chamber, mounted on an under-couch X-ray tube (Siemens Coroskop TOP with an optional dose reduction system), recorded the dose-area product (DAP) to the patient from 40 coronary angiographies and 42 coronary interventions by the femoral route. The corresponding numbers for radial access were 36 and 24, respectively. Using a human-shaped phantom, conversion factors between maximum entrance surface dose and DAP were derived for CA and CA plus PTCA, respectively. The dose to the staff was measured with TL dosimeters for 22 examinations. Fluoroscopy time and DAP were significantly (p=0.003) larger using the radial access route for coronary angiography (7.5 min, 51 Gy cm2) than the corresponding values obtained from femoral access route (4.6 min, 38 Gy cm2). For CA plus PTCA the fluoroscopy time and DAP were larger for radial access (18.4 min, 75 Gy cm2) than for femoral access (12.5 min, 47 Gy cm2; p=0.013). In our experience, radial access did significantly prolong the fluoroscopy time and increase the patient doses.


  • Receptor modeling for use in computerized optimization of imaging systems

    by Michael P. Sandborg, Gudrun Alm Carlsson, David R. Dance, Jan Persliden

    Inappropriate or poorly designed x-ray imaging systems can lead to inadequate image quality and/or excessive patient absorbed dose. To study this dilemma, we have developed a computer program, based on Monte Carlo methods, to model the imaging chain and to optimize the design of individual imaging system components. The Monte Carlo method is used to simulate the transport of x-ray photons through the patient and anti-scatter device and into the image receptor. Image quality is calculated in terms of contrast and signal-to-noise ratio (SNR) and patient risk in terms of mean absorbed dose. The model of the radiographic screen includes the statistics of x-ray to light conversion and diffusion of light photons and the spatial distribution of absorbed x rays. The optimal system was defined as that which, for a constant measure of image quality, results in the lowest mean absorbed dose in the patient. The results of the model agree with measured data. Examples are given for different measures of reducing the absorbed dose for constant SNR in a simulated lumbar spine examination. At the optimal tube potential, the dose reductions associated with using a thicker screen, a fiber-interspaced grid and an additional Cu-filtration are 53%, 42%, and 31%, respectively.