Bernhard Zielbauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bernhard Zielbauer has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
D. Ros
Université Paris-Sud 11
3 shared publicationsO. Guilbaud
Université Paris-Sud 11
3 shared publicationsS. Kazamias
Université Paris-Sud 11
3 shared publicationsT. Kuehl
Helmholtz Institute Jena
3 shared publicationsB. Ecker
Helmholtz Institute Jena
2 shared publications- B. Ecker
University of Mainz
2 shared publications
Latest Publications
- Open Access
- 5 September 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (9) , 178
Noise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.
- 5 September 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (9) , 178
Open AccessNoise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.
- 1 January 2014
- Published by Springer Nature
- p. 283-286
Heavy-Ion Spectroscopy with X-Ray Lasers at GSI
- 1 January 2014
- Published by Springer Nature
- p. 97-104
X-Ray Laser Developments at PHELIX
- 1 September 2013
- Published by IOP Publishing in Physica Scripta
- Vol. T156
A beamline for x-ray laser spectroscopy at the experimental storage ring at GSI
- 1 September 2013
- Published by IOP Publishing in Physica Scripta
- Vol. T156
A beamline for x-ray laser spectroscopy at the experimental storage ring at GSI
- 8 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8140, 814009
Strong field amplification of XUV: phase matching aspects
The dependence of the yield of high-order harmonic generation (HHG) on several important experimental parameters has been successfully modeled in the last 20 years by taking into account the single atom response and propagation effects. We extended this description by adding a stimulated emission process and named it x-ray parametric amplification (XPA). Beyond the super-quadratic increase of the XUV signal, which can be explained only in a limited pressure range by HHG theory, other observed characteristics like exponential growth, gain narrowing, strong blue-shift, beam divergence, etc. and their dependence on laser intensity and gas pressure can be explained accurately only by the new XPA model. We experimentally demonstrated XPA in Argon in the spectral range of 40-50 eV in excellent agreement with the theory. XPA holds the promise to realize a new class of bright x-ray sources for spectroscopy.
- 8 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8140, 814009
Strong field amplification of XUV: phase matching aspects
The dependence of the yield of high-order harmonic generation (HHG) on several important experimental parameters has been successfully modeled in the last 20 years by taking into account the single atom response and propagation effects. We extended this description by adding a stimulated emission process and named it x-ray parametric amplification (XPA). Beyond the super-quadratic increase of the XUV signal, which can be explained only in a limited pressure range by HHG theory, other observed characteristics like exponential growth, gain narrowing, strong blue-shift, beam divergence, etc. and their dependence on laser intensity and gas pressure can be explained accurately only by the new XPA model. We experimentally demonstrated XPA in Argon in the spectral range of 40-50 eV in excellent agreement with the theory. XPA holds the promise to realize a new class of bright x-ray sources for spectroscopy.
- 14 January 2010
- Published by Springer Nature in Applied Physics B
- Vol. 100 (4) , 731-736
Stable and fully controlled long-time operation of a soft X-ray laser for user application experiments
- 14 January 2010
- Published by Springer Nature in Applied Physics B
- Vol. 100 (4) , 731-736
Stable and fully controlled long-time operation of a soft X-ray laser for user application experiments