Noise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter
Authors:
- Stephan SchreinerSSStephan Schreiner
- Bernhard AkstallerBABernhard Akstaller
- Lisa DietrichLDLisa Dietrich
- Pascal MeyerPMPascal Meyer
- Paul NeumayerPNPaul Neumayer
- Max SchusterMSMax Schuster
- Andreas WolfAWAndreas Wolf
- Bernhard ZielbauerBZBernhard Zielbauer
- Veronika LudwigVLVeronika Ludwig
- Thilo MichelTMThilo Michel
- Gisela AntonGAGisela Anton
- Stefan FunkSFStefan Funk
Open Access
- 5 September 2021
- journal article
- research article
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (9) , 178
Abstract
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.Keywords
This publication has 48 references indexed in Scilit:
- On a dark-field signal generated by micrometer-sized calcifications in phase-contrast mammographyPhysics in Medicine & Biology, 2013
- Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase steppingMedical Physics, 2011
- Commissioning and early experiments of the PHELIX facilityApplied Physics B, 2009
- Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sourcesNature Physics, 2006
- Recent Advances in X-ray Phase ImagingJapanese Journal of Applied Physics, 2005
- Phase objects in synchrotron radiation hard x-ray imagingJournal of Physics D: Applied Physics, 1996
- On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiationReview of Scientific Instruments, 1995
- Binary phase grating for array generation at 1/16 of Talbot lengthJournal of the Optical Society of America A, 1995
- Phase-contrast imaging of weakly absorbing materials using hard X-raysNature, 1995
- Measurement of Laser-Plasma Electron Density with a Soft X-ray Laser DeflectometerScience, 1994