Marian K. Rippy
Marian K. Rippy has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Andrew J. Marshall
Healionics Corporation, Seattle, Washington, USA
1 shared publication Andrew Wu
Medtronic Ardian, Mountain View, USA
1 shared publication- Benoit Detry
STAR Medical SA, Avenue Sabin 6, 1300, Wavre, Belgium
1 shared publication Christopher K. Zarins
Stanford University, Stanford, USA
1 shared publicationDenise Zarins
Medtronic Ardian, Mountain View, USA
1 shared publication- Don Minckler
University of California, Irvine
1 shared publication
Latest Publications
- Open Access
- 14 October 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-11
A novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration
Background: A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). Results: In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. Conclusions: The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.
- 14 October 2020
- Published by Springer Nature in BMC Biomedical Engineering
- Vol. 2 (1) , 1-11
Open AccessA novel suprachoroidal microinvasive glaucoma implant: in vivo biocompatibility and biointegration
Background: A major challenge for any glaucoma implant is their ability to provide long-term intraocular pressure lowering efficacy. The formation of a low-permeability fibrous capsule around the device often leads to obstructed drainage channels, which may impair the drainage function of devices. These foreign body-related limitations point to the need to develop biologically inert biomaterials to improve performance in reaching long-term intraocular pressure reduction. The aim of this study was to evaluate in vivo (in rabbits) the ocular biocompatibility and tissue integration of a novel suprachoroidal microinvasive glaucoma implant, MINIject™ (iSTAR Medical, Wavre, Belgium). Results: In two rabbit studies, no biocompatibility issue was induced by the suprachoroidal, ab-externo implantation of the MINIject™ device. Clinical evaluation throughout the 6 post-operative months between the sham and test groups were similar, suggesting most reactions were related to the ab-externo surgical technique used for rabbits, rather than the implant material itself. Histological analysis of ocular tissues at post-operative months 1, 3 and 6 revealed that the implant was well-tolerated and induced only minimal fibroplasia and thus minimal encapsulation around the implant. The microporous structure of the device became rapidly colonized by cells, mostly by macrophages through cell migration, which do not, by their nature, impede the flow of aqueous humor through the device. Time-course analysis showed that once established, pore colonization was stable over time. No fibrosis nor dense connective tissue development were observed within any implant at any time point. The presence of pore colonization may be the process by which encapsulation around the implant is minimized, thus preserving the permeability of the surrounding tissues. No degradation nor structural changes of the implant occurred during the course of both studies. Conclusions: The novel MINIject™ microinvasive glaucoma implant was well-tolerated in ocular tissues of rabbits, with observance of biointegration, and no biocompatibility issues. Minimal fibrous encapsulation and stable cellular pore colonization provided evidence of preserved drainage properties over time, suggesting that the implant may produce a long-term ability to enhance aqueous outflow.
- 28 July 2011
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 100 (12) , 1095-1101
Catheter-based renal sympathetic denervation: chronic preclinical evidence for renal artery safety
Background Renal sympathetic hyperactivity is associated with hypertension, a leading cause of mortality worldwide. Renal sympathetic denervation via the Symplicity Catheter System has been shown to decrease blood pressure by 33/11 mmHg by 6 months, with no radiofrequency (RF)-related adverse sequelae visible by CT/MR angiography or renal duplex ultrasound 6 months after the procedure. Here, we present preclinical work predating those clinical results. We performed therapeutic renal sympathetic denervation in a swine animal model to characterize the vascular safety and healing response 6 months after renal denervation therapy. Methods In December 2007, seven domestic swine received a total of 32 radiofrequency ablations via the Symplicity Catheter System and were euthanatized 6 months later. Renal angiography was done before, immediately after, and 6 months after procedure. The renal vessels were examined histologically with H&E and Movat pentachrome stains to identify evidence of vascular and neural injury. The kidneys and urinary system were also examined for evidence of gross and microscopic abnormalities. Results Renal nerve injury involved primarily nerve fibrosis, replacement of nerve fascicles with fibrous connective tissue, and thickening of the epineurium and perineurium. Renal arterial findings included fibrosis of 10–25% of the total media and underlying adventitia, with mild disruption of the external elastic lamina. No significant smooth muscle hyperplasia or inflammatory components were observed. There was no renal arterial stenosis or thrombosis observed by angiography or histology. No gross or microscopic device-related abnormalities were noted in the kidney, surrounding stroma, or urinary bladder. Conclusions In a swine model, renal denervation via the Symplicity Catheter System resulted in no clinically significant adverse renal artery or renal findings 6 months after the procedure. This is corroborated by the vascular safety profile demonstrated in subsequent human clinical studies.
- 28 July 2011
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 100 (12) , 1095-1101
Catheter-based renal sympathetic denervation: chronic preclinical evidence for renal artery safety
Background Renal sympathetic hyperactivity is associated with hypertension, a leading cause of mortality worldwide. Renal sympathetic denervation via the Symplicity Catheter System has been shown to decrease blood pressure by 33/11 mmHg by 6 months, with no radiofrequency (RF)-related adverse sequelae visible by CT/MR angiography or renal duplex ultrasound 6 months after the procedure. Here, we present preclinical work predating those clinical results. We performed therapeutic renal sympathetic denervation in a swine animal model to characterize the vascular safety and healing response 6 months after renal denervation therapy. Methods In December 2007, seven domestic swine received a total of 32 radiofrequency ablations via the Symplicity Catheter System and were euthanatized 6 months later. Renal angiography was done before, immediately after, and 6 months after procedure. The renal vessels were examined histologically with H&E and Movat pentachrome stains to identify evidence of vascular and neural injury. The kidneys and urinary system were also examined for evidence of gross and microscopic abnormalities. Results Renal nerve injury involved primarily nerve fibrosis, replacement of nerve fascicles with fibrous connective tissue, and thickening of the epineurium and perineurium. Renal arterial findings included fibrosis of 10–25% of the total media and underlying adventitia, with mild disruption of the external elastic lamina. No significant smooth muscle hyperplasia or inflammatory components were observed. There was no renal arterial stenosis or thrombosis observed by angiography or histology. No gross or microscopic device-related abnormalities were noted in the kidney, surrounding stroma, or urinary bladder. Conclusions In a swine model, renal denervation via the Symplicity Catheter System resulted in no clinically significant adverse renal artery or renal findings 6 months after the procedure. This is corroborated by the vascular safety profile demonstrated in subsequent human clinical studies.